NUNeal G. Uren

Neal G. Uren

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Neal G. Uren has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Native Aortic Valve Disease Progression and Bioprosthetic Valve Degeneration in Patients With Transcatheter Aortic Valve Implantation

    by Jacek Kwiecinski, Evangelos Tzolos, Timothy R.G. Cartlidge, Alexander Fletcher, Mhairi K. Doris, Rong Bing, Jason M. Tarkin, Michael A. Seidman, Gaurav S. Gulsin, Nicholas L. Cruden, et al.

    Background: Major uncertainties remain regarding disease activity within the retained native aortic valve, and regarding bioprosthetic valve durability, after transcatheter aortic valve implantation (TAVI). We aimed to assess native aortic valve disease activity and bioprosthetic valve durability in patients with TAVI in comparison with subjects with bioprosthetic surgical aortic valve replacement (SAVR). Methods: In a multicenter cross-sectional observational cohort study, patients with TAVI or bioprosthetic SAVR underwent baseline echocardiography, computed tomography angiography, and 18 F-sodium fluoride ( 18 F-NaF) positron emission tomography. Participants (n=47) were imaged once with 18 F-NaF positron emission tomography/computed tomography either at 1 month (n=9, 19%), 2 years (n=22, 47%), or 5 years (16, 34%) after valve implantation. Patients subsequently underwent serial echocardiography to assess for changes in valve hemodynamic performance (change in peak aortic velocity) and evidence of structural valve dysfunction. Comparisons were made with matched patients with bioprosthetic SAVR (n=51) who had undergone the same imaging protocol. Results: In patients with TAVI, native aortic valves demonstrated 18 F-NaF uptake around the outside of the bioprostheses that showed a modest correlation with the time from TAVI ( r =0.36, P =0.023). 18 F-NaF uptake in the bioprosthetic leaflets was comparable between the SAVR and TAVI groups (target-to-background ratio, 1.3 [1.2–1.7] versus 1.3 [1.2–1.5], respectively; P =0.27). The frequencies of imaging evidence of bioprosthetic valve degeneration at baseline were similar on echocardiography (6% versus 8%, respectively; P =0.78), computed tomography (15% versus 14%, respectively; P =0.87), and positron emission tomography (15% versus 29%, respectively; P =0.09). Baseline 18 F-NaF uptake was associated with a subsequent change in peak aortic velocity for both TAVI ( r =0.7, P r =0.7, P 18 F-NaF uptake was the only predictor of peak velocity progression ( P <0.001). Conclusions: In patients with TAVI, native aortic valves demonstrate evidence of ongoing active disease. Across imaging modalities, TAVI degeneration is of similar magnitude to bioprosthetic SAVR, suggesting comparable midterm durability. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02304276.


  • Open Access

    Acute coronary syndromes: assessing risk and choosing optimal pharmacological regimens for a superior outcome

    by Neal Uren

    Revolutionary strategies for management of acute coronary syndromes (ACSs) have been introduced over the past 15 years. Such innovations have occurred in the area of interventional cardiology (bare metal evolving to drug-eluting stents) as well as in pharmaco-therapy, particularly anti-platelet therapy. Agents including clopidogrel and glycoprotein IIb/IIIa receptor inhibitors have been developed, as adjuncts to aspirin, in order to better target the elevated platelet activity central to the thrombus that underlies ACS. Most importantly, there has been a greater emphasis placed upon a patient's risk for ischaemic complications when determining the overall management strategy including timing of angiography and medications. In the effort to improve outcomes for the most high-risk patients, there has been a continued focus on the development of newer therapies. Research has shown, however, that achieving clinical benefit may not require the formulation of the next generation of anti-platelet agent but may require a more astute awareness of patient risk, and the selection of management strategies that demonstrate the greatest benefit to them.


  • Open Access

    Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    by Emma S Houslay, Tristan Lawton, Anshuman Sengupta, Neal G Uren, Graham McKillop, David E Newby

    Background: Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods: Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results: A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion: Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.