Kimberly Edginton Bigelow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kimberly Edginton Bigelow has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Courtney Golembiewski
A Department of Mechanical and Aerospace Engineering, University of Dayton , Dayton , Ohio , USA
1 shared publicationHarold Merriman
B Department of Physical Therapy, University of Dayton , Dayton , Ohio , USA
1 shared publication- John R. Schultz
Affiliation Mechanical Engineering/Center for Human Machine Systems, Cleveland State University, Cleveland, Ohio, United States of America
1 shared publication - Julie Walsh-Messinger
University of Dayton
1 shared publication - Kurt Jackson
Department of Physical Therapy, University of Dayton, 300 College Park, Dayton, OH 45469, USA
1 shared publication Necip Berme
Department of Mechanical Engineering, The Ohio State University, Columbus
1 shared publication
Latest Publications
- 24 July 2019
- Published by Taylor & Francis in Assistive Technology
- Vol. 33 (6) , 318-325
The effects of a positional feedback device on rollator walker use: a validation study
Background: According to clinical guidelines, rolling walker users should walk with their feet between the posterior wheels of the walker; however approximately 50% of users do not. Objective: To describe the development and effects of a custom device designed to attach to a walker and provide visual feedback to encourage improved user position. Methods: Fourteen older adults participated in this study to validate the effects of this device when a 10% decrease in the users’ habitual distance away from the walker was encouraged via feedback. Users’ relative distances were recorded using a non-contact distance sensor within the device, while kinematics were measured using commercial wearable wireless inertial sensors. Results: Individuals were able to ambulate on average 20% closer or more to their walker when prescribed the visual feedback. This was primarily achieved through a reduction in shoulder flexion. Trunk and cervical postures were less generalizable as only small and variable changes were observed. Conclusions: These findings suggest that the device has promise, as individuals attended to the device and walked in a position closer to that recommended by clinical guidelines. The device did not appear to improve posture. Future work is needed to determine long-term effects.
- 24 July 2019
- Published by Taylor & Francis in Assistive Technology
- Vol. 33 (6) , 318-325
The effects of a positional feedback device on rollator walker use: a validation study
Background: According to clinical guidelines, rolling walker users should walk with their feet between the posterior wheels of the walker; however approximately 50% of users do not. Objective: To describe the development and effects of a custom device designed to attach to a walker and provide visual feedback to encourage improved user position. Methods: Fourteen older adults participated in this study to validate the effects of this device when a 10% decrease in the users’ habitual distance away from the walker was encouraged via feedback. Users’ relative distances were recorded using a non-contact distance sensor within the device, while kinematics were measured using commercial wearable wireless inertial sensors. Results: Individuals were able to ambulate on average 20% closer or more to their walker when prescribed the visual feedback. This was primarily achieved through a reduction in shoulder flexion. Trunk and cervical postures were less generalizable as only small and variable changes were observed. Conclusions: These findings suggest that the device has promise, as individuals attended to the device and walked in a position closer to that recommended by clinical guidelines. The device did not appear to improve posture. Future work is needed to determine long-term effects.
- Open Access
- 2 December 2010
- Published by Oxford University Press (OUP) in The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
- Vol. 66A (2) , 228-233
Development of a Protocol for Improving the Clinical Utility of Posturography as a Fall-Risk Screening Tool
The usefulness of posturography in the clinical screening of older adults for fall risk has been limited by a lack of standardization in testing methodology and data reporting. This study determines which testing condition and postural sway measures best differentiate recurrent fallers and nonrecurrent fallers. One hundred and fifty older adults were categorized based on their fall status in the past year. Participants performed four quiet-standing tasks, eyes open and eyes closed in both comfortable and narrow stance, for 60 seconds while standing on a force-measuring platform. Traditional and fractal measures were calculated from the center of pressure data. Logistic regression was performed to determine the model for each condition that best discriminated between recurrent fallers and nonrecurrent fallers. The eyes closed comfortable stance condition, with its associated model, best differentiated recurrent fallers and nonrecurrent fallers. Medial–lateral sway velocity, anterior–posterior short-term α-scaling exponent, medial–lateral short-term α-scaling exponent, mean frequency, body mass index, and age were included in this model. Sensitivity of the model was 75%, and specificity was 94%. This resulting model demonstrates potential to differentiate recurrent fallers and nonrecurrent fallers in an eyes closed comfortable stance condition. The inclusion of traditional sway parameters, fractal measures, and personal characteristics in this model demonstrates the importance of considering multiple descriptions of postural stability together rather than using only a single measure to establish fall risk.
- 2 December 2010
- Published by Oxford University Press (OUP) in The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
- Vol. 66A (2) , 228-233
Open AccessDevelopment of a Protocol for Improving the Clinical Utility of Posturography as a Fall-Risk Screening Tool
The usefulness of posturography in the clinical screening of older adults for fall risk has been limited by a lack of standardization in testing methodology and data reporting. This study determines which testing condition and postural sway measures best differentiate recurrent fallers and nonrecurrent fallers. One hundred and fifty older adults were categorized based on their fall status in the past year. Participants performed four quiet-standing tasks, eyes open and eyes closed in both comfortable and narrow stance, for 60 seconds while standing on a force-measuring platform. Traditional and fractal measures were calculated from the center of pressure data. Logistic regression was performed to determine the model for each condition that best discriminated between recurrent fallers and nonrecurrent fallers. The eyes closed comfortable stance condition, with its associated model, best differentiated recurrent fallers and nonrecurrent fallers. Medial–lateral sway velocity, anterior–posterior short-term α-scaling exponent, medial–lateral short-term α-scaling exponent, mean frequency, body mass index, and age were included in this model. Sensitivity of the model was 75%, and specificity was 94%. This resulting model demonstrates potential to differentiate recurrent fallers and nonrecurrent fallers in an eyes closed comfortable stance condition. The inclusion of traditional sway parameters, fractal measures, and personal characteristics in this model demonstrates the importance of considering multiple descriptions of postural stability together rather than using only a single measure to establish fall risk.