  • Adverse response to cardiac resynchronisation therapy in patients with septal scar on cardiac MRI preventing a septal right ventricular lead position

    by Simon G. Duckett, Matthew Ginks, Anoop Shetty, Senthil Kirubakaran, Julian Bostock, Stam Kapetanakis, Jaswinder Gill, Gerry Carr-White, Reza Razavi, C. Aldo Rinaldi

    Myocardial scar is an adverse factor when considering which patients are likely to respond to cardiac resynchronisation therapy (CRT). We hypothesized that septal scarring on magnetic resonance imaging (MRI) may be associated with a poor outcome from CRT, which may relate to the inability to place the right ventricular (RV) lead in the septum. Fifty patients (ejection fractions, 25 ± 8%; 45 men, 62.8 ± 14 years; 26 dilated cardiomyopathy; and 24 ischaemic cardiomyopathy (ICM)) receiving CRT underwent delayed enhancement cardiac MRI to assess location and burden of myocardial scar. Acute hemodynamic response (AHR) was evaluated at implant with a pressure wire in the left ventricular (LV) cavity. LV remodelling was determined by reduction in LV end-systolic volume at 6 months. The presence of ICM with septal scar was associated with a poor acute and chronic response to CRT. This was predominantly due to a worse response in patients with septal scar. Patients without septal scar had a better AHR with a 26.7 ± 28.9% rise in LV dP/dt max from baseline vs. −2.8 ± 14.5% for patients with septal scar (P = 0.01) with Biventricular (BIV) pacing. A greater proportion remodelled (56% vs. 20% (P = 0.02)). Furthermore, only 33% of patients with septal scar had an RV septal lead compared with 66% with no septal scar (P = 0.03). The presence of septal scar was associated with a poor acute and chronic response to CRT. This may relate to the inability to achieve a RV septal lead placement.


  • Invasive Acute Hemodynamic Response to Guide Left Ventricular Lead Implantation Predicts Chronic Remodeling in Patients Undergoing Cardiac Resynchronization Therapy

    by Simon G. Duckett, Matthew Ginks, Anoop K. Shetty, Julian Bostock, Jaswinder S. Gill, Shoaib Hamid, Stam Kapetanakis, Eliane Cunliffe, Reza Razavi, Gerry Carr-White, et al.


  • Open Access

    Relationship between endocardial activation sequences defined by high-density mapping to early septal contraction (septal flash) in patients with left bundle branch block undergoing cardiac resynchronization therapy

    by Simon G. Duckett, Oscar Camara, Matthew R. Ginks, Julian Bostock, Phani Chinchapatnam, Maxime Sermesant, Ali Pashaei, Pier D. Lambiase, Jaswinder S. Gill, Gerry S. Carr-White, et al.

    Early inward motion and thickening/thinning of the ventricular septum associated with left bundle branch block is known as the septal flash (SF). Correction of SF corresponds to response to cardiac resynchronization therapy (CRT). We hypothesized that SF was associated with a specific left ventricular (LV) activation pattern predicting a favourable response to CRT. We sought to characterize the spatio-temporal relationship between electrical and mechanical events by directly comparing non-contact mapping (NCM), acute haemodynamics, and echocardiography. Thirteen patients (63 ± 10 years, 10 men) with severe heart failure (ejection fraction 22.8 ± 5.8%) awaiting CRT underwent echocardiography and NCM pre-implant. Presence and extent of SF defined visually and with M-mode was fused with NCM bull's eye plots of endocardial activation patterns. LV–dP/dtmax was measured during different pacing modes. Five patients had a large SF, four small SF, and four no SF. Large SF patients had areas of conduction block in non-infarcted regions, whereas those with small or no SF did not. Patients with large SF had greater acute response to LV and biventricular (BIV) pacing vs. those with small/no SF (% increase dP/dt 28 ± 14 vs. 11 ± 19% for LV pacing and 42 ± 28 vs. 22 ± 21% for BIV pacing) (P< 0.05). This translated into a more favourable chronic response to CRT. The lines of conduction block disappeared with LV/BIV pacing while remaining with right ventricle pacing. A strong association exists between electrical activation and mechanical deformation of the septum. Correction of both mechanical synchrony and the functional conduction block by CRT may explain the favourable response in patients with SF.


  • Open Access

    Cardiac MRI to investigate myocardial scar and coronary venous anatomy using a slow infusion of dimeglumine gadobenate in patients undergoing assessment for cardiac resynchronization therapy

    by Simon G. Duckett, Amedeo Chiribiri, Matthew R. Ginks, Stephen Sinclair, Benjamin R. Knowles, Rene Botnar, Gerry S. Carr‐White, Christopher A. Rinaldi, Eike Nagel, Reza Razavi, et al.

    Purpose: To evaluate a cardiac MR (CMR) examination with slow infusion of a high‐relaxivity contrast agent to visualize coronary venous anatomy (CVA) and myocardial scar in heart failure patients awaiting cardiac resynchronization therapy (CRT).Materials and Methods: Fourteen patients awaiting CRT (seven ischemic cardiomyopathy (ICM) and seven non‐ICM) and two with normal LV function underwent CMR on a 1.5 Tesla (T) MR scanner. Dimeglumine‐gadobenate was slowly infused. Bolus arrival in the LV was measured by a dynamic electrocardiogram (ECG) ‐triggered inversion recovery (IR) scan subsequent to starting an ECG‐triggered respiratory‐navigated three‐dimensional (3D) SSFP MR scan with IR preparation to acquire systolic whole‐heart anatomy for vein visualization. Delayed contrast‐enhanced MR scan was performed to assess myocardial scar. CVA obtained by CMR was compared with X‐ray venography in 11 patients. CVA and scar were segmented and registered for visual inspection.Results: For all subjects, there was excellent visualization of the CVA. All ICM and one non‐ICM patient showed scar. There was excellent correlation between veins seen by CMR and venography.Conclusion: We have demonstrated that slow infusion protocol of dimeglumine‐gadobenate can be used to assess both CVA and myocardial scar in a single MR examination. Furthermore, an image overlay technique has been used to show the relationship of scar to the CVA. J. Magn. Reson. Imaging 2011;33:87–95.


  • Advanced Image Fusion to Overlay Coronary Sinus Anatomy with Real‐Time Fluoroscopy to Facilitate Left Ventricular Lead Implantation in CRT

    by Simon G. Duckett, Matthew R Ginks, Benjamin R. Knowles, Yingliang Ma, Anoop Shetty, Julian Bostock, Michael Cooklin, Jas S. Gill, Gerry S. Carr‐White, Reza Razavi, et al.

    Background: Failure rate for left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is up to 12%. The use of segmentation tools, advanced image registration software, and high‐fidelity images from computerized tomography (CT) and cardiac magnetic resonance (CMR) of the coronary sinus (CS) can guide LV lead implantation. We evaluated the feasibility of advanced image registration onto live fluoroscopic images to allow successful LV lead placement. Methods: Twelve patients (11 male, 59 ± 16.8 years) undergoing CRT had three‐dimensional (3D) whole‐heart imaging (six CT, six CMR). Eight patients had at least one previously failed LV lead implant. Using segmentation software, anatomical models of the cardiac chambers, CS, and its branches were overlaid onto the live fluoroscopy using a prototype version of the Philips EP Navigator software to guide lead implantation. Results: We achieved high‐fidelity segmentations of cardiac chambers, coronary vein anatomy, and accurate registration between the 3D anatomical models and the live fluoroscopy in all 12 patients confirmed by balloon occlusion angiography. The CS was cannulated successfully in every patient and in 11, an LV lead was implanted successfully. (One patient had no acceptable lead values due to extensive myocardial scar.) Conclusion: Using overlaid 3D segmentations of the CS and cardiac chambers, it is feasible to guide CRT implantation in real time by fusing advanced imaging and fluoroscopy. This enabled successful CRT in a group of patients with previously failed implants. This technology has the potential to facilitate CRT and improve implant success. (PACE 2011; 34:226–234)


  • Open Access

    Realtime fusion of cardiac magnetic resonance imaging and computed tomography venography with X-ray fluoroscopy to aid cardiac resynchronisation therapy implantation in patients with persistent left superior vena cava

    by Simon G Duckett, Matthew Ginks, Anoop K. Shetty, Benjamin R. Knowles, John J. Totman, Amedeo Chiribiri, Ying-Liang Ma, Reza Razavi, Tobias Schaeffter, Gerry Carr-White, et al.

    Persistent left superior vena cava can lead to significant technical difficulties when implanting a left ventricular (LV) lead for cardiac resynchronisation therapy. We present two cases in which coronary sinus anatomy was reconstructed with computed tomography and magnetic resonance imaging and fused with live fluoroscopy to facilitate LV lead implantation.


  • Open Access

    A Novel Cardiac MRI Protocol To Guide Successful Cardiac Resynchronization Therapy Implantation

    by Simon G. Duckett, Matthew Ginks, Benjamin R. Knowles, Amedeo Chiribiri, Ying-Liang Ma, Reza Razavi, Tobias Schaeffter, Gerry Carr-White, C. Aldo Rinaldi, Kawal Rhode