LJLindsay C H John

Lindsay C H John

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lindsay C H John has a total of 1 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 June 2008
      • Vol. 49  (3) , 359-62

    An assessment of the potential use of transthoracic impedance measurement for the non-invasive monitoring of lung injury following cardiac surgery.

    by L C H John, I M Ervine

    Lung injury commonly occurs following cardiac surgery. More severe forms are associated with a high mortality. In order to diagnose it and monitor its progress with treatment, measurement of extravascular lung water is necessary. This is usually measured using either a double-indicator dilution or single-indicator technique. Both require intravascular lines and expensive consumables which make them unsuitable for the routine monitoring of cardiac surgical patients. It has been suggested that the measurement of bioelectrical impedance could provide a non-invasive alternative which would allow routine measurement in these patients. Extravascular lung water (EVLW) and index (EVLWI) were measured in 23 patients undergoing elective coronary artery bypass graft surgery at 3 time points before and after surgery using the PiCCO system. At the same times the Transthoracic Impedance ratio (TTIr) was also measured using the Bodystat Dual Scan 2005. The corresponding measurements of TTIr were compared statistically with both EVLW and EVLWI. The resulting correlation coefficients were very low (<0.1). Transthoracic Impedance does not appear to reflect extravascular lung water and is therefore unlikely to be useful in the routine monitoring of cardiac surgical patients.

  • Open Access

    Modified closure technique for reducing sternal dehiscence; a clinical and in vitro assessment

    by Lindsay C.H. John

    Objective: Although the incidence of sternal dehiscence is low its mortality can be high. An alternative technique is described (modified closure) which aims to redistribute the dehiscence force into the longer longitudinal axis rather than the shorter transverse axis, thereby maximising the closure strength. Four ethibond sutures, which interlock anteriorly, are used in addition to eight transverse sternal wires. The aim of the study was to assess the modified closure using both an in vitro and a clinical study. Methods: (a) In vitro study: A weight and traction pulley system applied a force of 0.1 kN to pairs of silicone rubber hemisterna approximated to each other using alternative closure techniques. The dehiscence tendency (DT) was measured as the amount of separation under tension. Using 10 pairs of hemisterna for each closure technique the measured DT for the modified closure (MC) was compare with those for each of five alternative closures (two figure-of-eight and four transverse sutures (2C), 6 (6T), 8 (8T), 10 (10T) and 12 transverse sutures (12T)). (b) Clinical study: The incidence of sternal dehiscence for the first 4 years of a consultants’ practice (using 8T) was compared with the second 4 years (using MC). Results: (a) Measured DT (mean ± SEM), (MC: 149 ± 14; 6T: 256 ± 13; 8T: 223 ± 9; 10T: 213 ± 13; 12T: 203 ± 8; 2C: 294 ± 15). DT was significantly smaller for MC (p < 0.003). (b) The incidence of dehiscence was significantly smaller in the second 4 years (MC) than in the first (8T): 0.2% (1/529) versus 1.6% (13/788); p = 0.01 Conclusions: In vitro and clinical studies suggest that the modified closure technique can reduce the incidence of sternal dehiscence.


    • 1 January 2008
      • Vol. 18  (1) , 35-44

    A mathematical analysis of alternative sternal wound closures--an aid to reducing cardiac surgical mortality.

    by Lindsay C H John

    Sternal dehiscence is an important complication of cardiac surgery. A simple mathematical analysis is described for determining the relative strength (S) of different types of sternal closure. This is based upon resolving the tensions within the segments of a sternal wire to derive a dehiscence force. The strength of the closure (S) is the ratio of the volume of sternum which the dehiscence force acts upon to the dehiscence force itself. The derived S values varied from 4.3 for a closure using 6 transverse wires to 11.4 for a closure using the Modified Technique. The analysis suggested that closures which redistribute the transverse force to act obliquely upon a greater volume of sternum, such as the Modified Technique, are less likely to fail.