Akiyo Sadato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akiyo Sadato has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Kazuhide Adachi
Fujita Health University
7 shared publications - Ichiro Nakahara
Fujita Health University Bantane Hospital, Nagoya, Japan
5 shared publications Motoharu Hayakawa
Department of Neurosurgery, Fujita Health University, Toyoake, Aichi 470-1192, Japan
5 shared publicationsYuichi Hirose
Department of Neurosurgery, Fujita Health University, Toyoake, Aichi 470-1192, Japan
5 shared publicationsH Kikuchi
3 shared publicationsM. Hayakawa
Department of Neurosurgery, Fujita Health University Faculty of Medicine; Toyoake, Aichi, Japan
3 shared publications
Latest Publications
- Open Access
- 25 February 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (11) , 1044-1048
Reduction of thromboembolic complications during the endovascular treatment of unruptured aneurysms by employing a tailored dual antiplatelet regimen using aspirin and prasugrel
Background Thromboembolic complications (TECs) are frequent during the endovascular treatment of unruptured aneurysms. To prevent TECs, dual antiplatelet therapy using aspirin and clopidogrel is recommended for the perioperative period. In patients with a poor response, clopidogrel is a risk factor for TECs. To prevent TECs, our study assessed the stratified use of prasugrel. Methods Patients who underwent endovascular therapy for unruptured cerebral aneurysms from April 2017 to August 2019 were enrolled in this clinical study and given premedication with aspirin and clopidogrel for 2 weeks prior to the procedure. P2Y12 reaction units (PRU) were measured using the VerifyNow assay on the day before the procedure (tailored group). In subgroups with PRU Results The tailored and non-tailored groups comprised 167 and 50 patients, respectively. TECs occurred in 11 (6.6%) and 8 (16%) patients in the tailored and non-tailored groups (P=0.048), respectively. The HR for TECs was significantly reduced in the tailored group (HR 0.3, 95% CI 0.11 to 0.81); P=0.017) compared with the non-tailored group. Conclusion The results suggest that tailored dual antiplatelet therapy medication with PRU significantly reduces the frequency of TECs without increasing hemorrhagic complications.
- 25 February 2021
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (11) , 1044-1048
Open AccessReduction of thromboembolic complications during the endovascular treatment of unruptured aneurysms by employing a tailored dual antiplatelet regimen using aspirin and prasugrel
Background Thromboembolic complications (TECs) are frequent during the endovascular treatment of unruptured aneurysms. To prevent TECs, dual antiplatelet therapy using aspirin and clopidogrel is recommended for the perioperative period. In patients with a poor response, clopidogrel is a risk factor for TECs. To prevent TECs, our study assessed the stratified use of prasugrel. Methods Patients who underwent endovascular therapy for unruptured cerebral aneurysms from April 2017 to August 2019 were enrolled in this clinical study and given premedication with aspirin and clopidogrel for 2 weeks prior to the procedure. P2Y12 reaction units (PRU) were measured using the VerifyNow assay on the day before the procedure (tailored group). In subgroups with PRU Results The tailored and non-tailored groups comprised 167 and 50 patients, respectively. TECs occurred in 11 (6.6%) and 8 (16%) patients in the tailored and non-tailored groups (P=0.048), respectively. The HR for TECs was significantly reduced in the tailored group (HR 0.3, 95% CI 0.11 to 0.81); P=0.017) compared with the non-tailored group. Conclusion The results suggest that tailored dual antiplatelet therapy medication with PRU significantly reduces the frequency of TECs without increasing hemorrhagic complications.
- Open Access
- 14 September 2018
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 13 (03) , 619-625
Relationship between the volume rate of Ed coil (Ed Ratio) and packing density in endosaccular embolization of cerebral aneurysms
Purpose: A high packing density (PD) (i.e., coil volume per aneurysm volume) helps prevent recanalization after endosaccular embolization of cerebral aneurysms. We hypothesized that the use of soft coils may be useful to raise PD and retrospectively investigated the correlation between the ED coil volume rate (i.e., volume ratio of all placed coils) and PD in patients treated with endosaccular embolization using this coil. Methods: Excluding aneurysms treated with a stent, 292 aneurysms treated using ED coils were included in this study. The 292 aneurysms and aneurysms with ≥30%, ≥40%, and ≥50% ED coil volume rates (202, 168, and 129 aneurysms, respectively) underwent linear regression analysis of the following seven factors' influence on PD:ED ratio, aneurysm volume, neck width, height, maximum diameter, dome-to-neck ratio, and aspect ratio. Results: Independent factors of a high PD were high ED ratio and small neck width on analyses of aneurysms with an ED ratio of ≥40% and ≥50%. Only neck width was an independent factor on analyses of all 292 aneurysms and aneurysms with ED ratio of ≥30%. Conclusion: The use of ED coils in high volume rate correlated with a high PD and may contribute to prevent recanalization in small aneurysms.
- 14 September 2018
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 13 (03) , 619-625
Open AccessRelationship between the volume rate of Ed coil (Ed Ratio) and packing density in endosaccular embolization of cerebral aneurysms
Purpose: A high packing density (PD) (i.e., coil volume per aneurysm volume) helps prevent recanalization after endosaccular embolization of cerebral aneurysms. We hypothesized that the use of soft coils may be useful to raise PD and retrospectively investigated the correlation between the ED coil volume rate (i.e., volume ratio of all placed coils) and PD in patients treated with endosaccular embolization using this coil. Methods: Excluding aneurysms treated with a stent, 292 aneurysms treated using ED coils were included in this study. The 292 aneurysms and aneurysms with ≥30%, ≥40%, and ≥50% ED coil volume rates (202, 168, and 129 aneurysms, respectively) underwent linear regression analysis of the following seven factors' influence on PD:ED ratio, aneurysm volume, neck width, height, maximum diameter, dome-to-neck ratio, and aspect ratio. Results: Independent factors of a high PD were high ED ratio and small neck width on analyses of aneurysms with an ED ratio of ≥40% and ≥50%. Only neck width was an independent factor on analyses of all 292 aneurysms and aneurysms with ED ratio of ≥30%. Conclusion: The use of ED coils in high volume rate correlated with a high PD and may contribute to prevent recanalization in small aneurysms.
- Open Access
- 1 March 2018
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 13 (01) , 119-122
Use of detachable coils without the need of a double marker microcatheter: Technical note
When using detachable coils for cerebral aneurysm embolization, it is necessary to place a microcatheter with radiopaque markers at 2 sites (tip and 3 cm proximal from the tip) in most cases. Detachable coils that can be positioned independently from the proximal marker may facilitate new applications utilizing their characteristics. Herein, we report 2 cases that were treated with new applications. Detachable coils that function to electrically detect the moment they come out of the microcatheter were used. In one patient with a large aneurysm with an irregular shape, coil embolization was applied by advancing the catheter more than 3 cm from the aneurysm neck to the caudally protruded compartment near the proximal end of the neck, which was difficult to reach with the coil. In the other patient with cerebral arteriovenous malformation (AVM), microcatheters for AVM without a proximal marker were used for coil embolization before Onyx injection: Coil embolization was applied through one microcatheter to a site more proximal than the tip of the other microcatheter, followed by Onyx injection through the distal catheter, by which the nidus was continuously penetrated from the initiation of injection, obtaining an effect similar to that of the plug and push technique. Through the use of detachable coils, which are not dependent on the visibility of the proximal marker, the limitation of catheter positioning is reduced and the applicable types of catheter increase, which may facilitate to enable its use for new clinical indications.
- 1 March 2018
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 13 (01) , 119-122
Open AccessUse of detachable coils without the need of a double marker microcatheter: Technical note
When using detachable coils for cerebral aneurysm embolization, it is necessary to place a microcatheter with radiopaque markers at 2 sites (tip and 3 cm proximal from the tip) in most cases. Detachable coils that can be positioned independently from the proximal marker may facilitate new applications utilizing their characteristics. Herein, we report 2 cases that were treated with new applications. Detachable coils that function to electrically detect the moment they come out of the microcatheter were used. In one patient with a large aneurysm with an irregular shape, coil embolization was applied by advancing the catheter more than 3 cm from the aneurysm neck to the caudally protruded compartment near the proximal end of the neck, which was difficult to reach with the coil. In the other patient with cerebral arteriovenous malformation (AVM), microcatheters for AVM without a proximal marker were used for coil embolization before Onyx injection: Coil embolization was applied through one microcatheter to a site more proximal than the tip of the other microcatheter, followed by Onyx injection through the distal catheter, by which the nidus was continuously penetrated from the initiation of injection, obtaining an effect similar to that of the plug and push technique. Through the use of detachable coils, which are not dependent on the visibility of the proximal marker, the limitation of catheter positioning is reduced and the applicable types of catheter increase, which may facilitate to enable its use for new clinical indications.
- 12 July 2017
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (4) , 351-354
Carotid stenting for unilateral stenosis can increase contralateral hemispheric cerebral blood flow
Background: The revascularization of carotid stenosis can increase ipsilateral cerebral blood flow (CBF). Occasionally, elevated CBF is also evident on the contralateral side, but this phenomenon is poorly understood.Objective: To analyze retrospectively the relationship between a contralateral CBF increase and several clinical and radiologic features.Materials and methods: We retrospectively analyzed 40 patients with unilateral cervical carotid stenosis treated by carotid artery stenting (CAS). Using123I-iodamphetamine single-photon emission computed tomography (SPECT); we compared pre- and postoperative hemispheric CBF on both sides. We investigated the influence of the following five factors on the increase of the contralateral hemispheric CBF: stenosis grade (≥50% or <50%, according to the North American Symptomatic Carotid Endarterectomy Trial criteria); age; the presence of anterior and posterior communicating arteries; postoperative hyperperfusion on the stenotic side; and the presence of cerebral steal phenomenon during preoperative acetazolamide-challenge SPECT.Results: Following unilateral CAS, mean hemispheric CBF increased significantly on both sides: from 33.4±5.6 (mean ± SD) to 38.7±7.8 mL/min on the operated side (paired t test, p<0.001) and f35.4±5.4 to 39.2±7.2 mL/min on the contralateral side (p<0.001). In a general linear model, stenosis grade (≥50%) alone was significantly correlated with the increase of the CBF on the contralateral side (p=0.03).Conclusion: Revascularization by CAS for unilateral carotid stenosis can increase hemispheric CBF on both sides. Increase of the contralateral CBF is correlated with stenosis grade (≥50%).
- 12 July 2017
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (4) , 351-354
Carotid stenting for unilateral stenosis can increase contralateral hemispheric cerebral blood flow
Background: The revascularization of carotid stenosis can increase ipsilateral cerebral blood flow (CBF). Occasionally, elevated CBF is also evident on the contralateral side, but this phenomenon is poorly understood.Objective: To analyze retrospectively the relationship between a contralateral CBF increase and several clinical and radiologic features.Materials and methods: We retrospectively analyzed 40 patients with unilateral cervical carotid stenosis treated by carotid artery stenting (CAS). Using123I-iodamphetamine single-photon emission computed tomography (SPECT); we compared pre- and postoperative hemispheric CBF on both sides. We investigated the influence of the following five factors on the increase of the contralateral hemispheric CBF: stenosis grade (≥50% or <50%, according to the North American Symptomatic Carotid Endarterectomy Trial criteria); age; the presence of anterior and posterior communicating arteries; postoperative hyperperfusion on the stenotic side; and the presence of cerebral steal phenomenon during preoperative acetazolamide-challenge SPECT.Results: Following unilateral CAS, mean hemispheric CBF increased significantly on both sides: from 33.4±5.6 (mean ± SD) to 38.7±7.8 mL/min on the operated side (paired t test, p<0.001) and f35.4±5.4 to 39.2±7.2 mL/min on the contralateral side (p<0.001). In a general linear model, stenosis grade (≥50%) alone was significantly correlated with the increase of the CBF on the contralateral side (p=0.03).Conclusion: Revascularization by CAS for unilateral carotid stenosis can increase hemispheric CBF on both sides. Increase of the contralateral CBF is correlated with stenosis grade (≥50%).
- Open Access
- 6 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155062
Large Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil Embolization of Cerebral Aneurysms
Tight coil packing with density of at least 20%–25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms at our institute. We included 355 small and large aneurysms. The following six factors were obtained from every case: aneurysm volume (mL), neck size (mm), packing density (%), residual volume (mL), rupture status at presentation, and stent assistance (with or without stent). The data were then subjected to multivariate logistic regression analysis to identify significant risk factors for recanalization. Recanalization occurred in 61 aneurysms (17.2%). Significant predictors for recanalization were aneurysm volume (odds ratio, 15.3; P < 0.001) and residual volume (odds ratio, 30.9; P < 0.001), but not packing density (odds ratio, 0.98; P = 0.341). These results showed that for each 0.1-mL increase in aneurysm volume and residual volume, the risk of recanalization increased by 1.3 times and 1.4 times, respectively. The most influential risk factor for recanalization after coil embolization was residual volume, not packing density. The larger the aneurysm volume, the greater the packing density has to be to minimize the residual volume and risk of recanalization. Since tight coil packing has already been aimed, further innovation of coil property or embolization technique may be needed. Otherwise, different treatment modality such as flow diverter or parent artery occlusion may have to be considered.
- 6 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155062
Open AccessLarge Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil Embolization of Cerebral Aneurysms
Tight coil packing with density of at least 20%–25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms at our institute. We included 355 small and large aneurysms. The following six factors were obtained from every case: aneurysm volume (mL), neck size (mm), packing density (%), residual volume (mL), rupture status at presentation, and stent assistance (with or without stent). The data were then subjected to multivariate logistic regression analysis to identify significant risk factors for recanalization. Recanalization occurred in 61 aneurysms (17.2%). Significant predictors for recanalization were aneurysm volume (odds ratio, 15.3; P < 0.001) and residual volume (odds ratio, 30.9; P < 0.001), but not packing density (odds ratio, 0.98; P = 0.341). These results showed that for each 0.1-mL increase in aneurysm volume and residual volume, the risk of recanalization increased by 1.3 times and 1.4 times, respectively. The most influential risk factor for recanalization after coil embolization was residual volume, not packing density. The larger the aneurysm volume, the greater the packing density has to be to minimize the residual volume and risk of recanalization. Since tight coil packing has already been aimed, further innovation of coil property or embolization technique may be needed. Otherwise, different treatment modality such as flow diverter or parent artery occlusion may have to be considered.
- 31 July 2015
- Published by Springer Nature in Neurosurgical Review
- Vol. 39 (1) , 109-114
Effects of anatomic characteristics of aneurysms on packing density in endovascular coil embolization: analysis of a single center’s experience
When embolizing cerebral aneurysms, dense coil packing may prevent recanalization but this may be influenced by the aneurysm morphology. We have analyzed retrospectively the relationship between anatomic features and the volumetric coil packing density. We analyzed 452 aneurysms in 434 patients treated by coil embolization without stenting, expressing packing density as volume embolization ratio (VER, volume of inserted coils/aneurysm volume). Six morphological variables (neck width, height, maximum diameter, dome to neck ratio (DNR), and aspect ratio), aneurysm location, and whether the aneurysm was ruptured or unruptured were analyzed with respect to dense (VER ≥20 %) or loose (VER 20 % were achieved for 272 aneurysms, with a mean VER of 24.7 %. The mean VER of the remaining 180 aneurysms was 15.6 %. In univariate analyses, the predictors for dense packing were having an anterior circulation, DNR, aspect ratio, and neck width. In multivariate analysis, the independent predictors were smaller neck width (odds ratio (OR) 0.8735; 95 % confidence interval (CI) 0.7635–0.9993) and larger aspect ratio (OR 1.6679; 95 % CI 1.0460–2.6594). ROC analysis showed optimal cutoff values for an aspect ratio of 1.35 (sensitivity 69.5 %, specificity 51.7 %) and a neck width of 3.13 mm (sensitivity 51.1 %, specificity 27.8 %). Although dense coil packing is still difficult to achieve in wide-necked aneurysms without the use of stents, packing with VER >20 % is expected to be achieved when the height is 1.35 times larger than the neck width.
- 31 July 2015
- Published by Springer Nature in Neurosurgical Review
- Vol. 39 (1) , 109-114
Effects of anatomic characteristics of aneurysms on packing density in endovascular coil embolization: analysis of a single center’s experience
When embolizing cerebral aneurysms, dense coil packing may prevent recanalization but this may be influenced by the aneurysm morphology. We have analyzed retrospectively the relationship between anatomic features and the volumetric coil packing density. We analyzed 452 aneurysms in 434 patients treated by coil embolization without stenting, expressing packing density as volume embolization ratio (VER, volume of inserted coils/aneurysm volume). Six morphological variables (neck width, height, maximum diameter, dome to neck ratio (DNR), and aspect ratio), aneurysm location, and whether the aneurysm was ruptured or unruptured were analyzed with respect to dense (VER ≥20 %) or loose (VER 20 % were achieved for 272 aneurysms, with a mean VER of 24.7 %. The mean VER of the remaining 180 aneurysms was 15.6 %. In univariate analyses, the predictors for dense packing were having an anterior circulation, DNR, aspect ratio, and neck width. In multivariate analysis, the independent predictors were smaller neck width (odds ratio (OR) 0.8735; 95 % confidence interval (CI) 0.7635–0.9993) and larger aspect ratio (OR 1.6679; 95 % CI 1.0460–2.6594). ROC analysis showed optimal cutoff values for an aspect ratio of 1.35 (sensitivity 69.5 %, specificity 51.7 %) and a neck width of 3.13 mm (sensitivity 51.1 %, specificity 27.8 %). Although dense coil packing is still difficult to achieve in wide-necked aneurysms without the use of stents, packing with VER >20 % is expected to be achieved when the height is 1.35 times larger than the neck width.
- 1 April 2015
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 21 (2) , 161-166
Use of a new soft and long coil reduces the number of coils to embolize a small aneurysm
In embolizing a cerebral aneurysm, achievement of a high-volume embolization ratio (VER: volume of inserted coils / aneurysm volume) is important because it may prevent coil compaction and recanalization. The goal of the study is to examine whether use of softer and longer coils gives an adequate VER with fewer coils, particularly for small aneurysms. Aneurysm volumes, VERs, and numbers of inserted coils were investigated in 23 cases of small aneurysms embolized using Infini coils, a long soft coil with a primary diameter of 0.010 inches (Infini group). An aneurysm volume- and VER-matched control (non-Infini) group of 59 cases was selected from patients treated at our facility. Data were also compared between subgroups of patients (n = 18 and n = 34 in the Infini and non-Infini groups, respectively) who were not treated with thicker coils with primary diameters of 0.0135–0.015 inches (18-type coils), since these coils affect the number of coils by increasing VER rapidly. Average aneurysm volumes and VERs did not differ significantly between the Infini and non-Infini groups. Significantly fewer coils were used per 0.1 ml aneurysm volume in the Infini group (4.08 coils in average) compared with the non-Infini group (5.67) (p < 0.001). In the non-18-type subgroups, the number of coils used remained significantly smaller in the Infini group (4.49) compared with the non-Infini group (6.72), (p < 0.001). To achieve VER ≥20%, use of Infini coils significantly decreased the number of coils required per unit volume of a small aneurysm.
- 1 April 2015
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 21 (2) , 161-166
Use of a new soft and long coil reduces the number of coils to embolize a small aneurysm
In embolizing a cerebral aneurysm, achievement of a high-volume embolization ratio (VER: volume of inserted coils / aneurysm volume) is important because it may prevent coil compaction and recanalization. The goal of the study is to examine whether use of softer and longer coils gives an adequate VER with fewer coils, particularly for small aneurysms. Aneurysm volumes, VERs, and numbers of inserted coils were investigated in 23 cases of small aneurysms embolized using Infini coils, a long soft coil with a primary diameter of 0.010 inches (Infini group). An aneurysm volume- and VER-matched control (non-Infini) group of 59 cases was selected from patients treated at our facility. Data were also compared between subgroups of patients (n = 18 and n = 34 in the Infini and non-Infini groups, respectively) who were not treated with thicker coils with primary diameters of 0.0135–0.015 inches (18-type coils), since these coils affect the number of coils by increasing VER rapidly. Average aneurysm volumes and VERs did not differ significantly between the Infini and non-Infini groups. Significantly fewer coils were used per 0.1 ml aneurysm volume in the Infini group (4.08 coils in average) compared with the non-Infini group (5.67) (p < 0.001). In the non-18-type subgroups, the number of coils used remained significantly smaller in the Infini group (4.49) compared with the non-Infini group (6.72), (p < 0.001). To achieve VER ≥20%, use of Infini coils significantly decreased the number of coils required per unit volume of a small aneurysm.
- 1 June 2011
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 17 (2) , 154-158
Comparison of Cerebral Aneurysm Volumes as Determined by Digitally Measured 3D Rotational Angiography and Approximation from Three Diameters
This study compared digital measurement of aneurysm volume by 3D rotational angiography (3D-RA) with an approximation technique using three diameters of an aneurysm to re-interpret previously reported optimal packing densities (volume embolization ratio, VER) in coil embolization of intracranial aneurysms. Estimation of the volume of saccular aneurysms is important for calculation of the VER, which is in turn reported to be useful for prediction of coil compaction. The conventional formula for the volume estimation is V=4/3 π(A/2) (B/2) (C/2), where A, B, and C are the aneurysmal height, length, and width measured on 3D-RA image respectively. Using 3D rotational angiography data from 74 aneurysms, the approximated volume generated using the conventional formula was directly compared with the digitally measured volume. The digitally measured volume varied from 0.003 ml to 7.935 ml, and the dome-to-neck ratio (D/N) from 0.79 up to 4.62. We found that the conventional formula almost systematically underestimated the volume by up to 50 %, particularly when the neck was large relative to the dome (D/N<2). On average, digitally measured volume was 1.26!1.29 times larger than the approximated volume obtained using the conventional formula. Conventional 2D angiography based aneurysm volume calculation tends to underestimate an aneurysm volume, so the so-called VER (volume embolization ratio) could be overestimated.
- 1 June 2011
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 17 (2) , 154-158
Comparison of Cerebral Aneurysm Volumes as Determined by Digitally Measured 3D Rotational Angiography and Approximation from Three Diameters
This study compared digital measurement of aneurysm volume by 3D rotational angiography (3D-RA) with an approximation technique using three diameters of an aneurysm to re-interpret previously reported optimal packing densities (volume embolization ratio, VER) in coil embolization of intracranial aneurysms. Estimation of the volume of saccular aneurysms is important for calculation of the VER, which is in turn reported to be useful for prediction of coil compaction. The conventional formula for the volume estimation is V=4/3 π(A/2) (B/2) (C/2), where A, B, and C are the aneurysmal height, length, and width measured on 3D-RA image respectively. Using 3D rotational angiography data from 74 aneurysms, the approximated volume generated using the conventional formula was directly compared with the digitally measured volume. The digitally measured volume varied from 0.003 ml to 7.935 ml, and the dome-to-neck ratio (D/N) from 0.79 up to 4.62. We found that the conventional formula almost systematically underestimated the volume by up to 50 %, particularly when the neck was large relative to the dome (D/N<2). On average, digitally measured volume was 1.26!1.29 times larger than the approximated volume obtained using the conventional formula. Conventional 2D angiography based aneurysm volume calculation tends to underestimate an aneurysm volume, so the so-called VER (volume embolization ratio) could be overestimated.
- 1 October 2010
- Published by Georg Thieme Verlag KG in min - Minimally Invasive Neurosurgery
- Vol. 53 (05/06) , 243-249
Endovascular Treatment of Vertebral Artery Dissection Using Stents and Coils: Its Pitfall and Technical Considerations
Objective: There are various options for the treatment of vertebral artery dissection aneurysms (VADA). Treatment with stents may be an effective method to treat VADA involving the posterior inferior cerebellar artery (PICA) and dissection of the dominant vertebral artery (VA). In this article, our personal experience of the treatment of VADAs by using stents and coils is reported. Methods: Since 1998, 26 cases of VADA have been treated by endovascular surgery by the first author. Of these cases, 6 cases were treated using stents, 3 of which were treated using stent and coils, 2 patients were treated using double overlapping stents, and the remaining one patient was treated using a single stent. Results: In all patients, dissection aneurysms were successfully covered by stents. There was one complication: an intraprocedural rupture during additional coil insertion without neurological deterioration. Follow-up angiography was performed in all 5 surviving patients except for one patient who died due to the severity of his original subarachnoid hemorrhage (mean duration of follow-up angiography 22.8 months, range 15–57 months). Total or subtotal disappearance of the VADA was achieved in all 5 cases. At one year after the treatment, all 5 surviving patients remained clinically stable without any neurological deficit. Conclusions: Treatment using stents is an effective alternative for the treatment of VA dissecting aneurysms, especially for lesions of the dominant VA or involving the PICA. However, additional coil insertion should be performed very carefully and may be avoided if stagnation of contrast material is achieved after overlapping stenting.
- 1 October 2010
- Published by Georg Thieme Verlag KG in min - Minimally Invasive Neurosurgery
- Vol. 53 (05/06) , 243-249
Endovascular Treatment of Vertebral Artery Dissection Using Stents and Coils: Its Pitfall and Technical Considerations
Objective: There are various options for the treatment of vertebral artery dissection aneurysms (VADA). Treatment with stents may be an effective method to treat VADA involving the posterior inferior cerebellar artery (PICA) and dissection of the dominant vertebral artery (VA). In this article, our personal experience of the treatment of VADAs by using stents and coils is reported. Methods: Since 1998, 26 cases of VADA have been treated by endovascular surgery by the first author. Of these cases, 6 cases were treated using stents, 3 of which were treated using stent and coils, 2 patients were treated using double overlapping stents, and the remaining one patient was treated using a single stent. Results: In all patients, dissection aneurysms were successfully covered by stents. There was one complication: an intraprocedural rupture during additional coil insertion without neurological deterioration. Follow-up angiography was performed in all 5 surviving patients except for one patient who died due to the severity of his original subarachnoid hemorrhage (mean duration of follow-up angiography 22.8 months, range 15–57 months). Total or subtotal disappearance of the VADA was achieved in all 5 cases. At one year after the treatment, all 5 surviving patients remained clinically stable without any neurological deficit. Conclusions: Treatment using stents is an effective alternative for the treatment of VA dissecting aneurysms, especially for lesions of the dominant VA or involving the PICA. However, additional coil insertion should be performed very carefully and may be avoided if stagnation of contrast material is achieved after overlapping stenting.