Dominic Varga
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dominic Varga has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Achim Woeckel
2 shared publicationsKathrin Strunz
2 shared publicationsRolf Kreienberg
2 shared publicationsVerena Geyer
2 shared publicationsZiad Atassi
2 shared publicationsA. Wöckel
1 shared publication
Latest Publications
- 23 April 2010
- Published by S. Karger AG in Oncology
- Vol. 78 (3-4) , 189-195
Does Guideline-Adherent Therapy Improve the Outcome for Early-Onset Breast Cancer Patients?
Background and Objective: Guidelines for the treatment of early-onset breast cancer have been proposed in several countries, but to date, their impact on outcomes is unverified. The objective of this study was to evaluate the association between guideline-adherent versus nonadherent treatment and recurrence-free survival (RFS) and overall survival (OAS) in early-onset breast cancer patients. Methods: A total of 1,778 patients were included in the study, of whom 111 were 35 years or younger and 1,667 were between 36 and 55 years. RFS and OAS were compared between the two groups, with respect to multiple parameters. All survival data were adjusted for tumor characteristics and analyzed with respect to guideline adherence according to the German Step 3 guidelines. Results: Statistically significant differences between the two groups (<35 years, 36–55 years) were observed with regard to breast surgery (p = 0.002) and hormone therapy (p = 0.006). Both groups were treated identically in terms of guideline adherence concerning axillary dissection (p = 0.9), radiation therapy (p = 0.7) and chemotherapy (p = 0.556). Young breast cancer patients whose treatment adhered to guideline recommendations had increased RFS and OAS [RFS: p = 0.030, hazard ratio (HR) 2.95, 95% confidence interval (CI) 1.11–7.83; OAS: p ≤ 0.001, HR 2.92, 95% CI 2.01–4.23]. Conclusion: Guideline-adherent treatment for early-onset breast cancer patients significantly improves OAS and RFS and should therefore be demanded for all patients.
- 23 April 2010
- Published by S. Karger AG in Oncology
- Vol. 78 (3-4) , 189-195
Does Guideline-Adherent Therapy Improve the Outcome for Early-Onset Breast Cancer Patients?
Background and Objective: Guidelines for the treatment of early-onset breast cancer have been proposed in several countries, but to date, their impact on outcomes is unverified. The objective of this study was to evaluate the association between guideline-adherent versus nonadherent treatment and recurrence-free survival (RFS) and overall survival (OAS) in early-onset breast cancer patients. Methods: A total of 1,778 patients were included in the study, of whom 111 were 35 years or younger and 1,667 were between 36 and 55 years. RFS and OAS were compared between the two groups, with respect to multiple parameters. All survival data were adjusted for tumor characteristics and analyzed with respect to guideline adherence according to the German Step 3 guidelines. Results: Statistically significant differences between the two groups (<35 years, 36–55 years) were observed with regard to breast surgery (p = 0.002) and hormone therapy (p = 0.006). Both groups were treated identically in terms of guideline adherence concerning axillary dissection (p = 0.9), radiation therapy (p = 0.7) and chemotherapy (p = 0.556). Young breast cancer patients whose treatment adhered to guideline recommendations had increased RFS and OAS [RFS: p = 0.030, hazard ratio (HR) 2.95, 95% confidence interval (CI) 1.11–7.83; OAS: p ≤ 0.001, HR 2.92, 95% CI 2.01–4.23]. Conclusion: Guideline-adherent treatment for early-onset breast cancer patients significantly improves OAS and RFS and should therefore be demanded for all patients.
- 20 April 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (04) , 387-392
Value of Ultrasound in Preoperative Local Staging in Early Breast Cancer
Ziel: Ziel der vorliegenden Arbeit war es, die Übereinstimmung der Metrik von intramammären Herdläsionen zwischen Mammasonografie und histologischem Präparat zu untersuchen und mögliche Einflussfaktoren auf Untersuchungsdiskrepanzen zu charakterisieren. Material und Methoden: Bei 460 Patientinnen, von denen 445 maligne Läsionen aufwiesen, wurden retrospektiv die sonografischen Ergebnisse mit den Maßen des Operationspräparates verglichen. Des Weiteren wurde der Datensatz nach Histologie, Tumorstadium, Alter, Grading und neoadjuvanter Therapie analysiert. Ergebnisse: Der Vergleich zwischen Mammasonografie und Operationspräparat zeigt eine exakte Größenmessung der Läsionen vor allem im Stadium T 1 und T 2 und bei duktal invasiven Karzinomen. Mit höherem Tumorstadium wird die Sonografie in der Messung ungenauer. Alter und Grading beeinflussen die Messgenauigkeit der Sonografie nicht. Lobulär invasive Mammakarzinome weisen ebenfalls eine hohe Ungenauigkeit auf. Schlussfolgerung: Je größer das Tumorstadium, desto ungenauer wird die Mammasonografie. Da die Unterschiede in der Messgenauigkeit sowohl in der univariaten, wie auch in der multivarianten Analyse gleich sind, ist davon auszugehen, dass Tumorstadium und histologischer Typ aufeinander keinen Einfluss im Sinne der Messgenauigkeit haben. Purpose: The purpose of this study was to determine the precision of breast ultrasound for the measurement of breast lesions compared to the histological measurement. A number of other dependent variables were also analyzed. Material and Methods: 460 patients with 445 malignant lesions were examined using breast ultrasound and the lesions were measured and compared to the histologically measured size. The data was further analyzed according to histology, tumor stage, age, grading and therapy. Results: Metric comparison showed good correlation between sonography and the pathologically measured size of breast lesions, especially in tumor stage T 1 and T 2 and within ductal invasive carcinomas. Higher tumor stages lead to imprecise measurements and the histological type of lobular invasive carcinoma also results in imprecise measurements. Age and grading do not influence measurement precision. Conclusion: Breast ultrasound allows precise measurement of breast lesions especially at lower tumor stages. The higher the tumor stage, the more imprecise the measurement becomes. Multivariate analysis shows no cross impact between tumor stage and histological type with respect to the quality of measurement.
- 20 April 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (04) , 387-392
Value of Ultrasound in Preoperative Local Staging in Early Breast Cancer
Ziel: Ziel der vorliegenden Arbeit war es, die Übereinstimmung der Metrik von intramammären Herdläsionen zwischen Mammasonografie und histologischem Präparat zu untersuchen und mögliche Einflussfaktoren auf Untersuchungsdiskrepanzen zu charakterisieren. Material und Methoden: Bei 460 Patientinnen, von denen 445 maligne Läsionen aufwiesen, wurden retrospektiv die sonografischen Ergebnisse mit den Maßen des Operationspräparates verglichen. Des Weiteren wurde der Datensatz nach Histologie, Tumorstadium, Alter, Grading und neoadjuvanter Therapie analysiert. Ergebnisse: Der Vergleich zwischen Mammasonografie und Operationspräparat zeigt eine exakte Größenmessung der Läsionen vor allem im Stadium T 1 und T 2 und bei duktal invasiven Karzinomen. Mit höherem Tumorstadium wird die Sonografie in der Messung ungenauer. Alter und Grading beeinflussen die Messgenauigkeit der Sonografie nicht. Lobulär invasive Mammakarzinome weisen ebenfalls eine hohe Ungenauigkeit auf. Schlussfolgerung: Je größer das Tumorstadium, desto ungenauer wird die Mammasonografie. Da die Unterschiede in der Messgenauigkeit sowohl in der univariaten, wie auch in der multivarianten Analyse gleich sind, ist davon auszugehen, dass Tumorstadium und histologischer Typ aufeinander keinen Einfluss im Sinne der Messgenauigkeit haben. Purpose: The purpose of this study was to determine the precision of breast ultrasound for the measurement of breast lesions compared to the histological measurement. A number of other dependent variables were also analyzed. Material and Methods: 460 patients with 445 malignant lesions were examined using breast ultrasound and the lesions were measured and compared to the histologically measured size. The data was further analyzed according to histology, tumor stage, age, grading and therapy. Results: Metric comparison showed good correlation between sonography and the pathologically measured size of breast lesions, especially in tumor stage T 1 and T 2 and within ductal invasive carcinomas. Higher tumor stages lead to imprecise measurements and the histological type of lobular invasive carcinoma also results in imprecise measurements. Age and grading do not influence measurement precision. Conclusion: Breast ultrasound allows precise measurement of breast lesions especially at lower tumor stages. The higher the tumor stage, the more imprecise the measurement becomes. Multivariate analysis shows no cross impact between tumor stage and histological type with respect to the quality of measurement.
- 3 January 2010
- Published by Springer Nature in Archives of Gynecology and Obstetrics
- Vol. 282 (4) , 427-432
Comparison of early onset breast cancer patients to older premenopausal breast cancer patients
The objective of this study was to show differences between breast cancer patients ≤35 and >35 years with regard to tumor characteristics and to present the patient-relevant outcomes overall survival (OAS) and recurrence-free survival (RFS). We analyzed data from 119 women aged 35 years or younger with breast cancer and compared multiple parameters against breast cancer patients between 36 and 55 (n = 1,097), all pre-menopausal. Data were adjusted for tumor characteristics and therapy. There was no statistically significant difference in tumor size, axillary lymph node involvement, and histological subtypes. On the contrary, grading lymphovascular invasion and receptor negativity showed statistically significant differences. Unadjusted hazard ratio are 2.11 (1.32–3.39) (OAS) and 1.92 (1.35–2.73) (RFS). Multi-adjusted hazard ratio are 2.97 (1.70–5.18) (OAS) and 2.11 (1.42–3.13) (RFS). In conclusion, young breast cancer patients still have a poor prognosis. Even after adjustment of the data, OAS and RFS showed a worse prognosis. Normal prognostic factors like tumor size, axillary lymph node involvement, and grading can therefore be not the explanation for the more aggressive disease progress within early onset breast cancer patients.
- 3 January 2010
- Published by Springer Nature in Archives of Gynecology and Obstetrics
- Vol. 282 (4) , 427-432
Comparison of early onset breast cancer patients to older premenopausal breast cancer patients
The objective of this study was to show differences between breast cancer patients ≤35 and >35 years with regard to tumor characteristics and to present the patient-relevant outcomes overall survival (OAS) and recurrence-free survival (RFS). We analyzed data from 119 women aged 35 years or younger with breast cancer and compared multiple parameters against breast cancer patients between 36 and 55 (n = 1,097), all pre-menopausal. Data were adjusted for tumor characteristics and therapy. There was no statistically significant difference in tumor size, axillary lymph node involvement, and histological subtypes. On the contrary, grading lymphovascular invasion and receptor negativity showed statistically significant differences. Unadjusted hazard ratio are 2.11 (1.32–3.39) (OAS) and 1.92 (1.35–2.73) (RFS). Multi-adjusted hazard ratio are 2.97 (1.70–5.18) (OAS) and 2.11 (1.42–3.13) (RFS). In conclusion, young breast cancer patients still have a poor prognosis. Even after adjustment of the data, OAS and RFS showed a worse prognosis. Normal prognostic factors like tumor size, axillary lymph node involvement, and grading can therefore be not the explanation for the more aggressive disease progress within early onset breast cancer patients.