Latest Publications
- 1 April 2004
- Vol. 70 (2) , 142-7
Lower limb salvage surgery with MUTARS endoprostheses: 2 to 7 year results.
The reconstruction of bone defects remains a challenge in orthopaedic oncology. Allogenic and autologous bone grafts, as well as megaprostheses are well-recognised methods for bone reconstruction. Modular, both cemented and cementless, endoprosthetic systems have become more popular to bridge defects of different sizes. The clinical and radiological results of 50 consecutive patients treated with MUTARS endoprostheses between 1995 and 2000 were evaluated in a prospective clinical study. The average follow-up was 46 months (25-86 months). Clinical evaluation showed good results with an average Enneking-Score of 72% (33-100%, SD +/- 19). Radiological evaluation showed various patterns of bone remodelling including extracortical bone bridging. Early symptomatic loosening occurred in 11 cases, necessitating revision surgery. In conclusion, the use of the MUTARS Endoprosthesis may be a valuable tool in the treatment of major bone defects in the lower limb, if the problems with the first-generation design can be solved.
- 1 April 2004
- Vol. 70 (2) , 142-7
Lower limb salvage surgery with MUTARS endoprostheses: 2 to 7 year results.
The reconstruction of bone defects remains a challenge in orthopaedic oncology. Allogenic and autologous bone grafts, as well as megaprostheses are well-recognised methods for bone reconstruction. Modular, both cemented and cementless, endoprosthetic systems have become more popular to bridge defects of different sizes. The clinical and radiological results of 50 consecutive patients treated with MUTARS endoprostheses between 1995 and 2000 were evaluated in a prospective clinical study. The average follow-up was 46 months (25-86 months). Clinical evaluation showed good results with an average Enneking-Score of 72% (33-100%, SD +/- 19). Radiological evaluation showed various patterns of bone remodelling including extracortical bone bridging. Early symptomatic loosening occurred in 11 cases, necessitating revision surgery. In conclusion, the use of the MUTARS Endoprosthesis may be a valuable tool in the treatment of major bone defects in the lower limb, if the problems with the first-generation design can be solved.
- 1 June 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (6) , 541-547
Stabilität und Okklusionsverhalten 6 verschiedener femoraler Markraumstopper
Markraumstopper (MRS) sind integraler Bestandteil moderner Zementiertechnik bei der Implantation von Hüfttotalendoprothesen. Durch den Verschluss der Markhöhle wird ein Entweichen des applizierten Zements nach distal verhindert und damit der intramedulläre Druckaufbau erhöht. Dies verbessert die Penetrationsfähigkeit des Zements in den Knochen und sekundär die Scherbeanspruchbarkeit der Zement-Knochen-Verbindung. Auf dem Markt sind eine Vielzahl verschiedener Modelle erhältlich, die sich in Design und Material voneinander unterscheiden. In einem biomechanischen Modell wurden 6 verschiedene MRS im Hinblick auf intramedullären Implantationsdruck, Einbringkraft und v. a. Stabilität und Okklusionsfähigkeit untersucht. In Kunstknochen wurde eine Druck- und Stabilitätsmessung während Implantation und standardisierter Zement- und Druckapplikation durchgeführt. Der “REX Cement Stop™” erreichte als einziger intramedullär expandierbarer MRS in allen Parametern die signifikant besten Ergebnisse. Mit den flexiblen Gelatinestoppern (Biostop G®, IMSET®, Plugin'Tech®) ließ sich ebenfalls eine ausreichende Markraumabdichtung und gute Stabilität erzielen, bei jedoch etwas höheren Implantationsdrücken und -kräften. Die eher rigiden Polyethylenrestriktoren (BUCK™, Universal Cement Restrictor) hingegen wiesen eine verminderte Stabilität und Okklusionsfähigkeit auf und können für den Einsatz mit modernen Zementiertechniken nicht empfohlen werden.
- 1 June 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (6) , 541-547
Stabilität und Okklusionsverhalten 6 verschiedener femoraler Markraumstopper
Markraumstopper (MRS) sind integraler Bestandteil moderner Zementiertechnik bei der Implantation von Hüfttotalendoprothesen. Durch den Verschluss der Markhöhle wird ein Entweichen des applizierten Zements nach distal verhindert und damit der intramedulläre Druckaufbau erhöht. Dies verbessert die Penetrationsfähigkeit des Zements in den Knochen und sekundär die Scherbeanspruchbarkeit der Zement-Knochen-Verbindung. Auf dem Markt sind eine Vielzahl verschiedener Modelle erhältlich, die sich in Design und Material voneinander unterscheiden. In einem biomechanischen Modell wurden 6 verschiedene MRS im Hinblick auf intramedullären Implantationsdruck, Einbringkraft und v. a. Stabilität und Okklusionsfähigkeit untersucht. In Kunstknochen wurde eine Druck- und Stabilitätsmessung während Implantation und standardisierter Zement- und Druckapplikation durchgeführt. Der “REX Cement Stop™” erreichte als einziger intramedullär expandierbarer MRS in allen Parametern die signifikant besten Ergebnisse. Mit den flexiblen Gelatinestoppern (Biostop G®, IMSET®, Plugin'Tech®) ließ sich ebenfalls eine ausreichende Markraumabdichtung und gute Stabilität erzielen, bei jedoch etwas höheren Implantationsdrücken und -kräften. Die eher rigiden Polyethylenrestriktoren (BUCK™, Universal Cement Restrictor) hingegen wiesen eine verminderte Stabilität und Okklusionsfähigkeit auf und können für den Einsatz mit modernen Zementiertechniken nicht empfohlen werden.
- 14 April 2003
- Published by Springer Nature in Calcified Tissue International
- Vol. 73 (2) , 115-121
Pattern of Periprosthetic Bone Remodeling Around Stable Uncemented Tapered Hip Stems: A prospective 84-month follow-up study and a Median 156-month Cross-Sectional Study with DXA
Bone resorption in the proximal femur is commonly seen after total hip arthroplasty (THA). With dual energy X-ray absorptiometry (DXA), the amount of bone mass (BMD) after implantation of a total hip stem can be precisely determined. However, prospective evaluation of the change of bone mass around the stem is only available for selected stems and short-term follow-up (up to 36 months). We analyzed BMD in patients who had undergone uncemented THA by DXA. Only patients with good clinical outcome (Merle d’ Aubigné score > 12) were included to obtain normative data for regular bone response. Two separate studies were performed: a prospective longitudinal study over 84 months with baseline values acquired within the first postoperative week (group A) (n = 26 patients) and a separate cross-sectional study, median follow-up 156 (124-178) months (group B) (n = 35 patients). Regions of interest were defined according to Gruen (ROI 1-7) and as net average ROI (net avg) for the periprosthetic femoral bone. After the initial remodeling process (12 months), BMD was compared to the 84-month (longitudinal) and the 156-month (cross-sectional) follow-up values to determine long-term periprosthetic changes of bone mineral density. The longitudinal study (group A), after the initial bone remodeling, showed no relevant further bone loss for women and men with BMD values 1.19 ± 0.15 and 1.40 ± 0.19, respectively, 12 months (women 89.8%, men 93.6%), and 1.19 ± 0.13 and 1.36 ± 0.18, respectively, after 84 months (women 90.0%, men 91.3%) (P = 0.98, P = 0.08,) respectively. The distribution of the BMD around the stem changed during the first 12 months. The ROIs around the proximal stem (ROI 1 and 7) showed the lowest absolute values at the 12-month follow-up and BMD in ROI 7 decreased most during the further follow-up until 84 months. The cross-sectional study (group B) showed no significant difference in BMD (net avg) values at a median of 156 months follow-up compared to the 12-month values (group A) (women: P = 0.77, men: P = 0.44). Initial BMD, implant diameter, and body mass index did not influence BMD loss (net avg) in this study, whereas age showed a weak correlation with BMD loss. The results show that after the initial remodeling process, no relevant further bone loss (net avg) occurs up to 84 months postsurgery, and values after a median of 156 months are similar. Normative long-term changes in the periprosthetic bone can be demonstrated in defined ROIs after implantation of a tapered corundum-blasted titanium stem with a good clinical result.
- 14 April 2003
- Published by Springer Nature in Calcified Tissue International
- Vol. 73 (2) , 115-121
Pattern of Periprosthetic Bone Remodeling Around Stable Uncemented Tapered Hip Stems: A prospective 84-month follow-up study and a Median 156-month Cross-Sectional Study with DXA
Bone resorption in the proximal femur is commonly seen after total hip arthroplasty (THA). With dual energy X-ray absorptiometry (DXA), the amount of bone mass (BMD) after implantation of a total hip stem can be precisely determined. However, prospective evaluation of the change of bone mass around the stem is only available for selected stems and short-term follow-up (up to 36 months). We analyzed BMD in patients who had undergone uncemented THA by DXA. Only patients with good clinical outcome (Merle d’ Aubigné score > 12) were included to obtain normative data for regular bone response. Two separate studies were performed: a prospective longitudinal study over 84 months with baseline values acquired within the first postoperative week (group A) (n = 26 patients) and a separate cross-sectional study, median follow-up 156 (124-178) months (group B) (n = 35 patients). Regions of interest were defined according to Gruen (ROI 1-7) and as net average ROI (net avg) for the periprosthetic femoral bone. After the initial remodeling process (12 months), BMD was compared to the 84-month (longitudinal) and the 156-month (cross-sectional) follow-up values to determine long-term periprosthetic changes of bone mineral density. The longitudinal study (group A), after the initial bone remodeling, showed no relevant further bone loss for women and men with BMD values 1.19 ± 0.15 and 1.40 ± 0.19, respectively, 12 months (women 89.8%, men 93.6%), and 1.19 ± 0.13 and 1.36 ± 0.18, respectively, after 84 months (women 90.0%, men 91.3%) (P = 0.98, P = 0.08,) respectively. The distribution of the BMD around the stem changed during the first 12 months. The ROIs around the proximal stem (ROI 1 and 7) showed the lowest absolute values at the 12-month follow-up and BMD in ROI 7 decreased most during the further follow-up until 84 months. The cross-sectional study (group B) showed no significant difference in BMD (net avg) values at a median of 156 months follow-up compared to the 12-month values (group A) (women: P = 0.77, men: P = 0.44). Initial BMD, implant diameter, and body mass index did not influence BMD loss (net avg) in this study, whereas age showed a weak correlation with BMD loss. The results show that after the initial remodeling process, no relevant further bone loss (net avg) occurs up to 84 months postsurgery, and values after a median of 156 months are similar. Normative long-term changes in the periprosthetic bone can be demonstrated in defined ROIs after implantation of a tapered corundum-blasted titanium stem with a good clinical result.
- 26 March 2003
- Published by Elsevier in Journal of Biomechanics
- Vol. 36 (6) , 835-843
In vitro performance of intramedullary cement restrictors in total hip arthroplasty
- 26 March 2003
- Published by Elsevier in Journal of Biomechanics
- Vol. 36 (6) , 835-843
In vitro performance of intramedullary cement restrictors in total hip arthroplasty
- 1 March 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (3) , 247-252
Fettembolie bei der Hüftendoprothesenimplantation
- 1 March 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (3) , 247-252
Fettembolie bei der Hüftendoprothesenimplantation
- Open Access
- 1 January 2003
- Published by Taylor & Francis in Acta Orthopaedica
- Vol. 74 (3) , 270-276
Robotic bone preparation does not increase cement penetration into the proximal femur
In a cadaver study, we prepared 20 matched pairs of human femora using chipped-tooth broaches and robotic milling with the same geometry. For robotic bone preparation the CASPAR robotic system with a rotating milling head was used. Cancel-lous bone was irrigated with 1 liter of pulsed lavage and the specimens were embedded in specially-designed pots. After vacuum mixing, bone cement was introduced in a retrograde manner and subjected to a standard pressure protocol with a constant force of 3,000 N. Radiographs were taken and horizontal sections were obtained at predefined levels, using a diamond saw. Microradiographs of the bone slices were taken, digitized and analyzed to assess cement penetration into cancellous bone. No femoral fractures or fissures occurred with either preparation technique. The microradiographic evaluation showed no morphometric differences between chipped-tooth broaches and robotic milling as regards cement penetration into cancellous bone. Therefore, in the presence of pulsed lavage, we conclude that robotic bone preparation does not increase cement penetration into cancellous bone of the proximal end of the femur.
- 1 January 2003
- Published by Taylor & Francis in Acta Orthopaedica
- Vol. 74 (3) , 270-276
Open AccessRobotic bone preparation does not increase cement penetration into the proximal femur
In a cadaver study, we prepared 20 matched pairs of human femora using chipped-tooth broaches and robotic milling with the same geometry. For robotic bone preparation the CASPAR robotic system with a rotating milling head was used. Cancel-lous bone was irrigated with 1 liter of pulsed lavage and the specimens were embedded in specially-designed pots. After vacuum mixing, bone cement was introduced in a retrograde manner and subjected to a standard pressure protocol with a constant force of 3,000 N. Radiographs were taken and horizontal sections were obtained at predefined levels, using a diamond saw. Microradiographs of the bone slices were taken, digitized and analyzed to assess cement penetration into cancellous bone. No femoral fractures or fissures occurred with either preparation technique. The microradiographic evaluation showed no morphometric differences between chipped-tooth broaches and robotic milling as regards cement penetration into cancellous bone. Therefore, in the presence of pulsed lavage, we conclude that robotic bone preparation does not increase cement penetration into cancellous bone of the proximal end of the femur.
- 1 January 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (1) , 41-50
Knochenzemente auf Basis von Polymethylmethacrylat
Knochenzemente auf Basis von Polymethylmethacrylat (PMMA) sind unverzichtbarer Bestandteil zur Verankerung von künstlichen Gelenken.Kunststoffe auf PMMA-Basis,ursprünglich entwickelt für den Einsatz in der Dentalchirurgie,werden seit über 40 Jahren erfolgreich mit sehr guten Langzeitergebnissen in der Endoprothetik eingesetzt. Der PMMA-Knochenzement als ein kaltpolymerisierender Kunststoff stellt trotz seiner scheinbar einfachen Konstitution aus einer Pulver- und einer Flüssigkeitskomponente ein komplexes Materialsystem dar, das nach der Implantation zahlreiche Funktionen am Einsatzort erfüllt.Seine Materialeigenschaften variieren je nach Zusammensetzung der Basiskomponenten und spielen bereits bei der Anmischung der beiden Komponenten eine bedeutende Rolle für das Verarbeitungsverhalten. Dieses unterschiedliche Verarbeitungsverhalten bestimmt wesentlich die Technik und die korrekte Umsetzung der Zementierung in vivo.Davon abhängig ist zudem die mechanische Stabilität des gehärteten Zementmantels und damit der gesamte Langzeiterfolg der Operation. Genormte Prüfmethoden kommen bei der Charakterisierung von Knochenzementen zum Einsatz,wobei die klinische Relevanz solcher Normen kritisch evaluiert werden muss.PMMA-Knochenzemente übernehmen zudem die Funktion eines Drug-delivery-Systems als lokaler Antibiotikaträger. Der vorliegende Artikel gibt einen Überblick über Aufbau und Eigenschaften von PMMA-Knochenzementen und deren Einflüsse auf die praktische Anwendung. Bone cements based on polymethylmethacrylate (PMMA) remain an important material for anchorage of artificial joints. Polymers based on PMMA originally developed for dental surgery have been successfully used in bone surgery for more than 40 years.At first sight the cold-curing PMMA bone cement seems to be a rather simple material consisting of a powder and a liquid. But in fact it is a complex material fulfilling various functions at its application site after the implantation. Its properties vary according to the composition of its basic elements. They already play a decisive role for the working behavior during mixing of both components.The differences in the working behavior considerably affect the cementing technique and the accurate application in vivo.These influence the mechanical performance of the cured cement mantle and the long-term results of the implantation. Standardized test methods are used to characterize bone cements,whereas the clinical relevance of the test methods has to be evaluated critically.Additionally,PMMA bone cements act as a drug delivery system as a local carrier of antibiotics.This paper gives a review of the composition and properties of PMMA bone cements and their influence on practical application.
- 1 January 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (1) , 41-50
Knochenzemente auf Basis von Polymethylmethacrylat
Knochenzemente auf Basis von Polymethylmethacrylat (PMMA) sind unverzichtbarer Bestandteil zur Verankerung von künstlichen Gelenken.Kunststoffe auf PMMA-Basis,ursprünglich entwickelt für den Einsatz in der Dentalchirurgie,werden seit über 40 Jahren erfolgreich mit sehr guten Langzeitergebnissen in der Endoprothetik eingesetzt. Der PMMA-Knochenzement als ein kaltpolymerisierender Kunststoff stellt trotz seiner scheinbar einfachen Konstitution aus einer Pulver- und einer Flüssigkeitskomponente ein komplexes Materialsystem dar, das nach der Implantation zahlreiche Funktionen am Einsatzort erfüllt.Seine Materialeigenschaften variieren je nach Zusammensetzung der Basiskomponenten und spielen bereits bei der Anmischung der beiden Komponenten eine bedeutende Rolle für das Verarbeitungsverhalten. Dieses unterschiedliche Verarbeitungsverhalten bestimmt wesentlich die Technik und die korrekte Umsetzung der Zementierung in vivo.Davon abhängig ist zudem die mechanische Stabilität des gehärteten Zementmantels und damit der gesamte Langzeiterfolg der Operation. Genormte Prüfmethoden kommen bei der Charakterisierung von Knochenzementen zum Einsatz,wobei die klinische Relevanz solcher Normen kritisch evaluiert werden muss.PMMA-Knochenzemente übernehmen zudem die Funktion eines Drug-delivery-Systems als lokaler Antibiotikaträger. Der vorliegende Artikel gibt einen Überblick über Aufbau und Eigenschaften von PMMA-Knochenzementen und deren Einflüsse auf die praktische Anwendung. Bone cements based on polymethylmethacrylate (PMMA) remain an important material for anchorage of artificial joints. Polymers based on PMMA originally developed for dental surgery have been successfully used in bone surgery for more than 40 years.At first sight the cold-curing PMMA bone cement seems to be a rather simple material consisting of a powder and a liquid. But in fact it is a complex material fulfilling various functions at its application site after the implantation. Its properties vary according to the composition of its basic elements. They already play a decisive role for the working behavior during mixing of both components.The differences in the working behavior considerably affect the cementing technique and the accurate application in vivo.These influence the mechanical performance of the cured cement mantle and the long-term results of the implantation. Standardized test methods are used to characterize bone cements,whereas the clinical relevance of the test methods has to be evaluated critically.Additionally,PMMA bone cements act as a drug delivery system as a local carrier of antibiotics.This paper gives a review of the composition and properties of PMMA bone cements and their influence on practical application.
- 1 January 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (1) , 2-10
Knochenersatzwerkstoffe
- 1 January 2003
- Published by Springer Nature in Der Orthopäde
- Vol. 32 (1) , 2-10
Knochenersatzwerkstoffe
- 1 February 2001
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und ihre Grenzgebiete
- Vol. 139 (01) , 52-63
Die Bedeutung der Jet-Lavage für das In-vitro- und In-vivo-Zementierergebnis
Fragestellung: Ziel dieser Studie war es, die Effektivität der pulsierenden Druckspülung (Jet-Lavage) gegenüber der manuellen Spritzenspülung im Hinblick auf das Zementierergebnis am Femur standardisiert in vitro und in vivo zu untersuchen. Methode: Zur Bearbeitung der Fragestellung wurden drei Teilversuche durchgeführt. Versuch A: An 36 linken humanen Leichenfemora wurden mit standardisierter Präparationstechnik und retrograder Druckzementiertechnik („pressurising”) Femurschaftprothesen implantiert. Zwei verschiedene Zementiergruppen wurden randomisiert. Je nach Gruppe erfolgte die Knochenlagerspülung entweder mit Jet-Lavage oder Blasenspritze, jeweils mit gleichem Spülvolumen. Versuch B: Um standardisierte Druckverhältnisse und seitengleiche Knochenqualität zu gewährleisten, wurde eine Zusatzstudie ohne Prothesenimplantation an 11 humanen Femurpaaren durchgeführt. Dabei unterschieden sich die präparierten Femurpaare lediglich hinsichtlich Spülart (1000 ml Jet-Lavage versus 1000 ml Blasenspritze). Alle Präparate wurden nach Knochenspülung in speziell angefertigte Kunststoffzylinder eingegipst. Nach retrograder Zementapplikation erfolgte die Druckbeaufschlagung des Zementes mit einer konstanten Kraft von 3000 N. Versuch C: Um die Zementpenetration in Abhängigkeit von der Knochenspülung in vivo beurteilen zu können, erfolgte im Rahmen eines neuen Schafmodells die standardisierte bilaterale und simultane Zementeinbringung und -kompression. Nach der Schenkelhalsosteotomie wurden beide Femora für die retrograde Zementeinbringung präpariert. Nach Randomisierung wurde eine Seite entweder manuell mit 250 ml Spülung oder mit dem identischen Volumen mittels Jet-Lavage gespült. Durch eine speziell für diesen Versuch angefertigte Zementkompressionsmaschine wurde anschließend im geschlossenen System der retrograd eingebrachte Zement simultan mit gleichem Druck komprimiert. Präparateaufarbeitung: Von allen Präparaten (Versuche A - C) wurden in regelmäßigen, standardisierten Abständen horizontale Sägeschnitte angefertigt. Von den erhaltenen Knochenscheiben wurden Mikroradiogramme erstellt und diese mittels Bildanalyse hinsichtlich der Zementpenetrationstiefe morphometrisch ausgewertet. Ergebnisse: Versuch A: Die Verwendung der Jet-Lavage erbrachte im Vergleich zu den manuell mittels Blasenspritze gespülten Femora signifikant bessere Zementpenetrationstiefen (p = 0,027). Bei dichter Spongiosa war der Unterschied zwischen Jet-Lavage und Blasenspritzenspülung stärker ausgeprägt. Versuch B: Im Links-rechts-Vergleich führte die Verwendung der Jet-Lavage im Vergleich zur manuellen Spülung bei gleichem Druck und Spülvolumen zu einer signifikante Verbesserung der Penetrationstiefe (p < 0,001).Versuch C: Auch im direkten Links-rechts-Vergleich in vivo bestätigte sich die signifikante Überlegenheit der Jet-Lavage (p = 0,002). Schlussfolgerungen: Die Verwendung der Jet-Lavage hat in vitro und in vivo wesentlichen Einfluss auf die verbesserte Penetrationstiefe von Knochenzement in das angrenzende Knochenlager und sollte in der zementierten Hüftendoprothetik sowohl aus zementiertechnischer Sicht als auch im Hinblick auf die Senkung des Fettembolierisikos als unverzichtbar angesehen werden. Aim: The purpose of this study was to determine the efficacy of pulsatile jet lavage and manual syringe lavage with regard to their cleansing capabilities as measured by cement penetration into cancellous bone both in vivo and in vitro. Methods: Three separate experiments were performed. Study A: In a cadaver study 36 left human cadaver femora were used for implantation of cemented femoral components. Conventional broaches were used for femoral preparation. Bone lavage was carried out either using jet lavage or manual syringe lavage of equal volume. The allocation to two different lavage groups was randomised. In both groups high-pressurising cementing techniques were implemented with the use of a proximal seal and additonal finger packing. Study B: To guarantee standardised cement pressurisation and equal bone quality, the influence of jet lavage (1000 ml) versus syringe lavage (1000 ml) was studied in 11 paired human cadaver femora in an additional study without prosthesis implantation. The specimens were imbedded in specially designed pots. Bone cement was applied in a retrograde manner and subjected to a standard pressure protocol with a constant force of 3000 N. Study C: To directly compare the effectiveness of both pulsatile jet and syringe lavage with regard to cement penetration in vivo, a new sheep model allowing for standardised bilateral, simultaneous cement pressurisation was used. After femoral neck osteotomies both femoral cavities of 10 sheep were prepared for retrograde cement application. After randomisation one side was lavaged with 250 ml irrigation using a bladder syringe, the contralateral femur with the identical volume but using a pulsatile lavage. A specially designed apparatus was used to allow for bilateral simultaneous cement pressurisation. Analysis: In all studies horizontal sections were obtained from the femoral specimens at predefined levels using a diamond saw. Microradiographs were taken and analysed using image analysis to assess cement penetration into cancellous bone. Results: Study A: Compared with syringe lavage the use of jet lavage significantly improved the penetration of cement into cancellous bone (p = 0.027). In the presence of strong, dense cancellous bone the findings were more pronounced. Study B: Our results show that in equal quality bone, the use of jet lavage yields significantly (p < 0.001) improved cement penetration compared to syringe lavage specimens. Study C: The results of the in vivo study confirmed the superiority of jet lavage bone surface preparation (p = 0.002). Conclusions: The use of jet lavage yields significantly improved interdigitation between cancellous bone and cement both in vitro and in vivo and should be regarded as mandatory in cemented total hip arthroplasty. High pressurising techniques are effective means to improve cement penetration, but should only be administered with jet lavage to reduce the risk of fat embolism. 01 Diese Arbeit wurde mit dem Themistocles-Gluck-Preis der DGOT 2000 prämiiert. Teile der Arbeit wurden bereits veröffentlicht im Orthopäden (Literaturstelle 19).
- 1 February 2001
- Published by Georg Thieme Verlag KG in Zeitschrift für Orthopädie und ihre Grenzgebiete
- Vol. 139 (01) , 52-63
Die Bedeutung der Jet-Lavage für das In-vitro- und In-vivo-Zementierergebnis
Fragestellung: Ziel dieser Studie war es, die Effektivität der pulsierenden Druckspülung (Jet-Lavage) gegenüber der manuellen Spritzenspülung im Hinblick auf das Zementierergebnis am Femur standardisiert in vitro und in vivo zu untersuchen. Methode: Zur Bearbeitung der Fragestellung wurden drei Teilversuche durchgeführt. Versuch A: An 36 linken humanen Leichenfemora wurden mit standardisierter Präparationstechnik und retrograder Druckzementiertechnik („pressurising”) Femurschaftprothesen implantiert. Zwei verschiedene Zementiergruppen wurden randomisiert. Je nach Gruppe erfolgte die Knochenlagerspülung entweder mit Jet-Lavage oder Blasenspritze, jeweils mit gleichem Spülvolumen. Versuch B: Um standardisierte Druckverhältnisse und seitengleiche Knochenqualität zu gewährleisten, wurde eine Zusatzstudie ohne Prothesenimplantation an 11 humanen Femurpaaren durchgeführt. Dabei unterschieden sich die präparierten Femurpaare lediglich hinsichtlich Spülart (1000 ml Jet-Lavage versus 1000 ml Blasenspritze). Alle Präparate wurden nach Knochenspülung in speziell angefertigte Kunststoffzylinder eingegipst. Nach retrograder Zementapplikation erfolgte die Druckbeaufschlagung des Zementes mit einer konstanten Kraft von 3000 N. Versuch C: Um die Zementpenetration in Abhängigkeit von der Knochenspülung in vivo beurteilen zu können, erfolgte im Rahmen eines neuen Schafmodells die standardisierte bilaterale und simultane Zementeinbringung und -kompression. Nach der Schenkelhalsosteotomie wurden beide Femora für die retrograde Zementeinbringung präpariert. Nach Randomisierung wurde eine Seite entweder manuell mit 250 ml Spülung oder mit dem identischen Volumen mittels Jet-Lavage gespült. Durch eine speziell für diesen Versuch angefertigte Zementkompressionsmaschine wurde anschließend im geschlossenen System der retrograd eingebrachte Zement simultan mit gleichem Druck komprimiert. Präparateaufarbeitung: Von allen Präparaten (Versuche A - C) wurden in regelmäßigen, standardisierten Abständen horizontale Sägeschnitte angefertigt. Von den erhaltenen Knochenscheiben wurden Mikroradiogramme erstellt und diese mittels Bildanalyse hinsichtlich der Zementpenetrationstiefe morphometrisch ausgewertet. Ergebnisse: Versuch A: Die Verwendung der Jet-Lavage erbrachte im Vergleich zu den manuell mittels Blasenspritze gespülten Femora signifikant bessere Zementpenetrationstiefen (p = 0,027). Bei dichter Spongiosa war der Unterschied zwischen Jet-Lavage und Blasenspritzenspülung stärker ausgeprägt. Versuch B: Im Links-rechts-Vergleich führte die Verwendung der Jet-Lavage im Vergleich zur manuellen Spülung bei gleichem Druck und Spülvolumen zu einer signifikante Verbesserung der Penetrationstiefe (p < 0,001).Versuch C: Auch im direkten Links-rechts-Vergleich in vivo bestätigte sich die signifikante Überlegenheit der Jet-Lavage (p = 0,002). Schlussfolgerungen: Die Verwendung der Jet-Lavage hat in vitro und in vivo wesentlichen Einfluss auf die verbesserte Penetrationstiefe von Knochenzement in das angrenzende Knochenlager und sollte in der zementierten Hüftendoprothetik sowohl aus zementiertechnischer Sicht als auch im Hinblick auf die Senkung des Fettembolierisikos als unverzichtbar angesehen werden. Aim: The purpose of this study was to determine the efficacy of pulsatile jet lavage and manual syringe lavage with regard to their cleansing capabilities as measured by cement penetration into cancellous bone both in vivo and in vitro. Methods: Three separate experiments were performed. Study A: In a cadaver study 36 left human cadaver femora were used for implantation of cemented femoral components. Conventional broaches were used for femoral preparation. Bone lavage was carried out either using jet lavage or manual syringe lavage of equal volume. The allocation to two different lavage groups was randomised. In both groups high-pressurising cementing techniques were implemented with the use of a proximal seal and additonal finger packing. Study B: To guarantee standardised cement pressurisation and equal bone quality, the influence of jet lavage (1000 ml) versus syringe lavage (1000 ml) was studied in 11 paired human cadaver femora in an additional study without prosthesis implantation. The specimens were imbedded in specially designed pots. Bone cement was applied in a retrograde manner and subjected to a standard pressure protocol with a constant force of 3000 N. Study C: To directly compare the effectiveness of both pulsatile jet and syringe lavage with regard to cement penetration in vivo, a new sheep model allowing for standardised bilateral, simultaneous cement pressurisation was used. After femoral neck osteotomies both femoral cavities of 10 sheep were prepared for retrograde cement application. After randomisation one side was lavaged with 250 ml irrigation using a bladder syringe, the contralateral femur with the identical volume but using a pulsatile lavage. A specially designed apparatus was used to allow for bilateral simultaneous cement pressurisation. Analysis: In all studies horizontal sections were obtained from the femoral specimens at predefined levels using a diamond saw. Microradiographs were taken and analysed using image analysis to assess cement penetration into cancellous bone. Results: Study A: Compared with syringe lavage the use of jet lavage significantly improved the penetration of cement into cancellous bone (p = 0.027). In the presence of strong, dense cancellous bone the findings were more pronounced. Study B: Our results show that in equal quality bone, the use of jet lavage yields significantly (p < 0.001) improved cement penetration compared to syringe lavage specimens. Study C: The results of the in vivo study confirmed the superiority of jet lavage bone surface preparation (p = 0.002). Conclusions: The use of jet lavage yields significantly improved interdigitation between cancellous bone and cement both in vitro and in vivo and should be regarded as mandatory in cemented total hip arthroplasty. High pressurising techniques are effective means to improve cement penetration, but should only be administered with jet lavage to reduce the risk of fat embolism. 01 Diese Arbeit wurde mit dem Themistocles-Gluck-Preis der DGOT 2000 prämiiert. Teile der Arbeit wurden bereits veröffentlicht im Orthopäden (Literaturstelle 19).