RORenato Souza Oliveira

Renato Souza Oliveira

*This is an algorithmically generated author record based on publicly available information.

Renato Souza Oliveira has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Assessment of Corneal Imaging Devices for Pediatric Patients: Evaluating Keratometric Measurements and Wavefront Aberrations

    by Renato Souza Oliveira, João Quadrado Gil, Maria João Quadrado, Mauro Campos

    Purpose: To evaluate the intrasession repeatability and agreement in keratometric and wavefront measurements among three different instruments (Pentacam HR, Nidek OPD-Scan III [OPD], and Zeiss i-Profiler Plus [IPROF]) in a pediatric population with various clinical features. Methods: This cross-sectional study included 217 eyes from 114 patients aged 6 to 17 years with different clinical features. The patients were divided into five groups: one control group (C) and four other groups, each presenting with keratoconus (KC), ocular allergy (OA), high astigmatism, or Down syndrome (DS). Statistical analyses included the intraclass correlation coefficient (ICC) for repeatability and Bland-Altman plots for agreement. Results: The findings demonstrated excellent repeatability of keratometric parameters across all devices (e.g., K1 ICC: 99.53% for Pentacam, 98.10% for OPD, and 98.31% for IPROF). The Pentacam showed superior repeatability for aberrometry indices in the KC group, with ICC values exceeding 98% for high-order aberration root mean square (HOA RMS) and Zernike polynomials. However, in the DS group, repeatability was significantly reduced for certain parameters, such as the index of surface variance (ICC: 40.13%) and HOA RMS (ICC: 42.86%). Bland-Altman plots revealed variations among devices in asphericity, vertical coma, and HOA RMS, with the KC group exhibiting broader limits of agreement compared to the control group. Conclusion: All three instruments showed good repeatability, with the Pentacam demonstrating superior reliability across all parameters, including aberrometry. However, agreement between devices was poor for key indices in patients with KC and DS.

  • Reply

    by Renato Souza Oliveira, João Quadrado Gil, Andreia Rosa, Maria João Quadrado, Mauro Campos

  • Quality and readability of online information on Keratoconus in Portugal and Brazil

    by Celso Costa, Renato Souza Oliveira, João Gil, Esmeralda Costa, Cristina Tavares, Andreia Rosa, Maria João Quadrado, Joaquim Murta

    Introduction: Keratoconus patients turn to the internet for answers to their disease expectations. Webpages are not filtered or submitted to evaluation before getting published. We aim to evaluate the quality and readability of the online information regarding keratoconus in Portugal and Brazil. Methods: Two independent ophthalmologists and one ophthalmologist supervisor evaluated 30 Portuguese and 30 Brazilian websites by order of appearance in Google with the word “Queratocone” and “Ceratocone”, respectively. Two quality scores were used: a quality index of consumer health information (DISCERN) and the Journal of the American Medical Association (JAMA) benchmark. Readability was evaluated with 3 scores: FleschKincaid Reading Ease (FRE), FleschKincaid Grade (FKG) and Automated Readability Index (ARI). Results: Sites from private hospitals or clinics were the most prevalent in both countries, followed by health platform sites. Final JAMA benchmark was 1.13 ± 1.18 in Portugal and 1.07 ± 1.00 in Brazil. Final DISCERN was 34.07 ± 11.71 in Portugal and 38.17 ± 10.51 in Brazil. FRE and FKG scores denoted “difficult to read” and “college school level” in both countries; ARI denoted “professor” level in Portugal and “college student” level in Brazil needed to understand the text, a statistically significant difference. There was no correlation between Google ranking and quality and readability scores. Discussion and Conclusions: The information on keratoconus available online to Portuguese-speaking patients is of poor quality and difficult to interpret. Ophthalmologists have a shared responsibility to tackle this challenge through multifold efforts. Educating our patients on how to find reputable websites can help them navigate their life with keratoconus.


  • Keratoconus Detection in High-Astigmatism Pediatric Patients: Optimal Pentacam Indices and Cutoff Points

    by Renato Souza Oliveira, João Quadrado Gil, Andreia Rosa, Maria João Quadrado, Mauro Campos

    Purpose: To assess the accuracy of various Pentacam indices in distinguishing keratoconus (KC) in pediatric patients with high astigmatism and to establish appropriate cutoff values. Methods: This prospective multicenter cross-sectional study included 312 eyes from 167 patients aged 6 to 18 years (mean age, 13.1 ± 3.2 years) evaluated with Oculus Pentacam HR. Patients were categorized into 4 groups: KC, forme fruste keratoconus, astigmatism greater than 2 diopters (Cyl2D), and control. A subgroup of Cyl2D comprised patients with astigmatism greater than 4 diopters (Cyl4D). Twenty-three Pentacam indices were analyzed, and receiver operating characteristic curves determined optimal cutoff points, sensitivity, and specificity. Results: The best indices for distinguishing KC from Cyl2D were high-order aberration root mean square of the anterior corneal surface (area under the receiver operating characteristic curve 0.987), Belin/Ambrosio enhanced ectasia total derivation (0.971), index of vertical asymmetry (0.971), average pachymetric progression index (0.962), maximum Ambrosio relational thickness (0.960), posterior elevation (0.952), and anterior elevation (0.948). The accuracy of these indices was highest in the control group and lowest in the Cyl4D group. Area under the receiver operating characteristic curve was significantly lower for fruste keratoconus than KC. Optimal cutoff values were higher for astigmatic patients than for those with no refractive error. Conclusions: Most indices effectively distinguished between KC and normal pediatric patients. For individuals with high astigmatism, we suggest focusing on specific indices such as high-order aberration root mean square, Belin/Ambrosio enhanced ectasia total derivation value, maximum Ambrosio relational thickness, average pachymetric progression index, and index of vertical asymmetry. Optimal cutoff points for these patients were higher than those for nonastigmatic children and differed from adult populations.


  • Open Access

    Scheimpflug Tomographic Indices for Classifying Normal, Down Syndrome and Clinical Keratoconus in Pediatric Patients

    by Renato Souza Oliveira, João Quadrado Gil, Andreia Rosa, Maria João Quadrado, Mauro Campos

    The study aimed to evaluate the precision of different Pentacam indices in diagnosing keratoconus (KC) in pediatric patients with and without Down Syndrome (DS) and determine suitable cutoff values. This prospective multicenter cross-sectional study evaluated 216 eyes of 131 patients aged 6–18 years (mean age 12.5 ± 3.2 years) using Pentacam. Patients were categorized into four groups: KC, forme fruste keratoconus (FK), DS, and control, excluding DS patients with topographic KC. Receiver operating characteristic curves were generated to determine the optimal cutoff points and compare the accuracy in identifying KC and FK in patients with and without DS. In DS patients, corneal morphology resembled KC features. The most effective indices for distinguishing KC in DS patients were the average pachymetric progression index (AUC = 0.961), higher-order aberration of the anterior cornea (AUC = 0.953), anterior elevation (AUC = 0.946), posterior elevation (AUC = 0.947), index of vertical asymmetry (AUC = 0.943), and Belin/Ambrosio enhanced ectasia total derivation value (AUC = 0.941). None of the indices showed good accuracy for distinguishing FK in DS patients. The thresholds of these indices differed significantly from non-DS patients. The results highlighted the need for DS-specific cutoff values to avoid false-positive or false-negative diagnoses in this population.

  • Late-onset haze associated with chikungunya infection

    by Renato Correa Souza de Oliveira, Tatiana Klejnberg, Celso Klejnberg, Mauro Campos

    A 42-year-old woman, who had undergone photorefractive keratectomy (PRK) 12 years earlier, complained of blurring of vision within 2 weeks of chikungunya infection. A central corneal stromal haze was observed in the left eye. Her corrected distance visual acuity was 20/200. The haze did not improve despite the use of topical corticosteroids; however, corneal clarity was restored, and vision improved with phototherapeutic keratectomy (PTK) and treatment with mitomycin-C (MMC) 0.02%. Late-onset stromal scarring can be triggered by systemic infection even years after PRK. PTK with MMC may be an effective treatment option for late-onset scars.

  • Rosai-Dorfman disease manifesting as an epibulbar ocular tumour

    by Renato Cs de Oliveira, Moacyr Rigueiro, Ana C Vieira, Denise de Freitas, Elcio Sato

    P>The authors report a rare case of extranodal Rosai-Dorfman disease without systemic involvement. A 14-year-old girl presented with a slowly progressive, non-tender, well-circumscribed, perilimbal nodule in the right eye. Excisional biopsy was performed and histopathologic and immunohistochemical analysis established the diagnosis. Systemic evaluation revealed no other masses. After complete excision of the epibulbar lesion, the patient is asymptomatic and remains on regular follow up with no signs of recurrence. Rosai-Dorfman disease is an infrequent, benign histiocytic disorder that can rarely manifest as an exclusive extranodal mass. We report a case of solitary epibulbar Rosai-Dorfman disease, successfully treated with complete surgical excision of the lesion.Universidade Federal de São Paulo, Dept Ophthalmol, São Paulo, BrazilUniversidade Federal de São Paulo, Dept Pathol, São Paulo, BrazilUniv Calif Davis, Dept Ophthalmol, Davis, CA 95616 USAUniversidade Federal de São Paulo, Dept Ophthalmol, São Paulo, BrazilUniversidade Federal de São Paulo, Dept Pathol, São Paulo, BrazilWeb of Scienc