MIMasahiko Ikeuchi

Masahiko Ikeuchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masahiko Ikeuchi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • E. Ueta

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan

    1 shared publication
  • N. Yamanaka

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan

    1 shared publication
  • Norio Yamanaka

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan

    1 shared publication
  • T. Tani

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan

    1 shared publication
  • Teruhiko Kawakami

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan

    1 shared publication
  • Toshikazu Tani

    Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan

    1 shared publication

Latest Publications

  • Determining the rotational alignment of the tibial component at total knee replacement

    by M. Ikeuchi, N. Yamanaka, Y. Okanoue, E. Ueta, T. Tani

    We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5°; 2° to 17°), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.


  • Open Access

    Safe zone for the superior gluteal nerve in the transgluteal approach to the dysplastic hip: Intraoperative evaluation using a nerve stimulator

    by Masahiko Ikeuchi, Teruhiko Kawakami, Norio Yamanaka, Yusuke Okanoue, Toshikazu Tani

    The superior gluteal nerve can be damaged during the transgluteal approach to the hip in total hip arthroplasty. We studied 30 patients with hip dysplasia who underwent total hip arthroplasty through the transgluteal approach. The course of the inferior branch of the superior gluteal nerve was identified using a nerve stimulator. The distance between the nerve and the tip of the greater trochanter was measured. The mean distance was 37 (25-45) mm at the anterior third, 40 (30-50) mm at the middle third, and 44 (35-55) mm at the posterior third of the gluteus medius. The distance was influenced by the severity of hip dysplasia and decreased as the degree of hip dysplasia became more severe. A 3-cm safe zone is appropriate in most dysplastic hips. In severely dysplastic hips, however, the superior gluteal nerve occasionally coursed within 3 cm of the tip of the greater trochanter. In such hips, a nerve stimulator can be used to identify the nerve.