Masahiko Ikeuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masahiko Ikeuchi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
E. Ueta
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan
1 shared publicationN. Yamanaka
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan
1 shared publicationNorio Yamanaka
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan
1 shared publicationT. Tani
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku 783-8505, Japan
1 shared publicationTeruhiko Kawakami
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan
1 shared publicationToshikazu Tani
Department of Orthopaedic Surgery, Kochi Medical School, Kochi University, Nankoku, 783-8505, Japan
1 shared publication
Latest Publications
- 1 January 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (1) , 45-49
Determining the rotational alignment of the tibial component at total knee replacement
We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5°; 2° to 17°), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.
- 1 January 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (1) , 45-49
Determining the rotational alignment of the tibial component at total knee replacement
We prospectively assessed the benefits of using either a range-of-movement technique or an anatomical landmark method to determine the rotational alignment of the tibial component during total knee replacement. We analysed the cut proximal tibia intraoperatively, determining anteroposterior axes by the range-of-movement technique and comparing them with the anatomical anteroposterior axis. We found that the range-of-movement technique tended to leave the tibial component more internally rotated than when anatomical landmarks were used. In addition, it gave widely variable results (mean 7.5°; 2° to 17°), determined to some extent by which posterior reference point was used. Because of the wide variability and the possibilities for error, we consider that it is inappropriate to use the range-of-movement technique as the sole method of determining alignment of the tibial component during total knee replacement.
- Open Access
- 1 January 2006
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (4) , 603-606
Safe zone for the superior gluteal nerve in the transgluteal approach to the dysplastic hip: Intraoperative evaluation using a nerve stimulator
The superior gluteal nerve can be damaged during the transgluteal approach to the hip in total hip arthroplasty. We studied 30 patients with hip dysplasia who underwent total hip arthroplasty through the transgluteal approach. The course of the inferior branch of the superior gluteal nerve was identified using a nerve stimulator. The distance between the nerve and the tip of the greater trochanter was measured. The mean distance was 37 (25-45) mm at the anterior third, 40 (30-50) mm at the middle third, and 44 (35-55) mm at the posterior third of the gluteus medius. The distance was influenced by the severity of hip dysplasia and decreased as the degree of hip dysplasia became more severe. A 3-cm safe zone is appropriate in most dysplastic hips. In severely dysplastic hips, however, the superior gluteal nerve occasionally coursed within 3 cm of the tip of the greater trochanter. In such hips, a nerve stimulator can be used to identify the nerve.
- 1 January 2006
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (4) , 603-606
Open AccessSafe zone for the superior gluteal nerve in the transgluteal approach to the dysplastic hip: Intraoperative evaluation using a nerve stimulator
The superior gluteal nerve can be damaged during the transgluteal approach to the hip in total hip arthroplasty. We studied 30 patients with hip dysplasia who underwent total hip arthroplasty through the transgluteal approach. The course of the inferior branch of the superior gluteal nerve was identified using a nerve stimulator. The distance between the nerve and the tip of the greater trochanter was measured. The mean distance was 37 (25-45) mm at the anterior third, 40 (30-50) mm at the middle third, and 44 (35-55) mm at the posterior third of the gluteus medius. The distance was influenced by the severity of hip dysplasia and decreased as the degree of hip dysplasia became more severe. A 3-cm safe zone is appropriate in most dysplastic hips. In severely dysplastic hips, however, the superior gluteal nerve occasionally coursed within 3 cm of the tip of the greater trochanter. In such hips, a nerve stimulator can be used to identify the nerve.