Ralf Bürgers
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ralf Bürgers has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Sebastian Hahnel
7 shared publicationsGerhard Handel
6 shared publicationsMartin Gosau
5 shared publicationsMartin Rosentritt
4 shared publicationsMichael Behr
4 shared publicationsTill Gerlach
2 shared publications
Latest Publications
- 1 July 2012
- Published by Elsevier in Archives of Oral Biology
- Vol. 57 (7) , 940-947
The effect of various topical peri-implantitis antiseptics on Staphylococcus epidermidis, Candida albicans, and Streptococcus sanguinis
- 1 July 2012
- Published by Elsevier in Archives of Oral Biology
- Vol. 57 (7) , 940-947
The effect of various topical peri-implantitis antiseptics on Staphylococcus epidermidis, Candida albicans, and Streptococcus sanguinis
- 1 March 2012
- Vol. 25 (2) , 138-44
Clinical performance of cast clasp-retained removable partial dentures: a retrospective study.
This retrospective study investigated the survival rate of 174 clasp-retained removable partial dentures (CR-RPDs) made at the Department of Prosthodontics of the Regensburg University Medical Center over a 25-year period (1984 to 2009). The study analyzed the frequency of and time to the fracture of clasps, connectors, or denture bases; the occurrence of caries or periodontal lesions; the loss of abutment teeth; and the necessity of maintenance procedures such as relining or treatment of pressure areas. The median follow-up time of 3 years was calculated using the inverse Kaplan-Meier method. The 5-year survival rate (time to renewal) of all CR-RPDs was 96.4%; the 10-year survival rate was 89.8%. Fractures most frequently occurred in clasps (n = 28, 16.1%) followed by major connectors (n = 9, 5.1%) and minor connectors (n = 6, 3.4%). The 5-year event-free rate for clasp fracture was 80.4%; the 10-year event-free rate was 76.9%. Caries lesions on abutment teeth were seen in 31.6% of patients, and 35.6% showed inflammation of the periodontal tissue surrounding the abutment teeth. The 5-year event-free rate for caries was 58.4%; the 10-year rate was 39.6%. A frequent complication was loss of abutment teeth (n = 15), but this complication was not age-dependent. After insertion of their prostheses, one-third of patients (n = 53, 30.5%) showed pressure areas of the mucosa. Significantly more (P < .001) pressure areas were caused by prostheses of the mandible (39.6%) than by those of the maxilla (12.5%). CR-RPDs showed a survival rate of approximately 90% after 10 years of oral service. The predominant complications during oral service were caries lesions, loss of abutment teeth, and fracture of clasps.
- 1 March 2012
- Vol. 25 (2) , 138-44
Clinical performance of cast clasp-retained removable partial dentures: a retrospective study.
This retrospective study investigated the survival rate of 174 clasp-retained removable partial dentures (CR-RPDs) made at the Department of Prosthodontics of the Regensburg University Medical Center over a 25-year period (1984 to 2009). The study analyzed the frequency of and time to the fracture of clasps, connectors, or denture bases; the occurrence of caries or periodontal lesions; the loss of abutment teeth; and the necessity of maintenance procedures such as relining or treatment of pressure areas. The median follow-up time of 3 years was calculated using the inverse Kaplan-Meier method. The 5-year survival rate (time to renewal) of all CR-RPDs was 96.4%; the 10-year survival rate was 89.8%. Fractures most frequently occurred in clasps (n = 28, 16.1%) followed by major connectors (n = 9, 5.1%) and minor connectors (n = 6, 3.4%). The 5-year event-free rate for clasp fracture was 80.4%; the 10-year event-free rate was 76.9%. Caries lesions on abutment teeth were seen in 31.6% of patients, and 35.6% showed inflammation of the periodontal tissue surrounding the abutment teeth. The 5-year event-free rate for caries was 58.4%; the 10-year rate was 39.6%. A frequent complication was loss of abutment teeth (n = 15), but this complication was not age-dependent. After insertion of their prostheses, one-third of patients (n = 53, 30.5%) showed pressure areas of the mucosa. Significantly more (P < .001) pressure areas were caused by prostheses of the mandible (39.6%) than by those of the maxilla (12.5%). CR-RPDs showed a survival rate of approximately 90% after 10 years of oral service. The predominant complications during oral service were caries lesions, loss of abutment teeth, and fracture of clasps.
- 1 January 2011
- Published by Springer Nature
- p. 763-767
Treatment Strategies of Temporomandibular Joint and Masticatory Muscle Disorders in Patients with Tinnitus
- 1 January 2011
- Published by Springer Nature
- p. 763-767
Treatment Strategies of Temporomandibular Joint and Masticatory Muscle Disorders in Patients with Tinnitus
- 1 January 2011
- Published by Springer Nature
- p. 435-440
Differential Diagnosis of Temporomandibular Joint and Masticatory Muscle Disorders in Patients with Tinnitus
- 1 January 2011
- Published by Springer Nature
- p. 435-440
Differential Diagnosis of Temporomandibular Joint and Masticatory Muscle Disorders in Patients with Tinnitus
- 1 January 2011
- Published by Springer Nature
- Vol. 1 (2) , 245-249
The Dentist
- 1 June 2010
- Published by Elsevier in Acta Biomaterialia
- Vol. 6 (6) , 2307-2313
Adhesion of Candida albicans to various dental implant surfaces and the influence of salivary pellicle proteins
- 1 June 2010
- Published by Elsevier in Acta Biomaterialia
- Vol. 6 (6) , 2307-2313
Adhesion of Candida albicans to various dental implant surfaces and the influence of salivary pellicle proteins
- 11 January 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (2) , 156-164
In vivo and in vitro biofilm formation on two different titanium implant surfaces
Objectives: The aim of the present in vitro and human in vivo study was twofold: first, to evaluate the initial biofilm formation on different titanium implant surfaces by means of two highly sensitive fluorescent techniques and, second, to correlate these findings to different surface properties.Materials and methods: In vivo biofilm formation was induced on purely machined (Pt) and on sand‐blasted and acid‐etched titanium (Prom) specimens, which were mounted buccally on individual splints and worn by six study participants for 12 h. In vitro bacterial adhesion was also investigated after incubation with Streptococcus sanguinis suspension (37°C, 2 h). Adherent bacteria were quantified by the following fluorescence techniques: Resazurin staining in combination with an automated fluorescence reader or live/dead cell labeling and fluorescence microscopy. Surface roughness (Ra) was determined with a perthometer, and surface free energy (SFE) was measured with a goniometer.Results: Prom showed a significantly higher median Ra (0.95 μm) and a significantly lower median SFE (18.3 mJ/m2) than Pt (Ra=0.15 μm; SFE=39.6 mJ/m2). The in vitro and in vivo tests showed a significantly higher bacterial adhesion to Prom than to Pt, and the initial biofilm formation on Pt corresponded to the circular surface modifications on the machined substratum. Both observations may be attributed to the predominant influence of surface roughness on bacterial adhesion. No significant differences in the percentage of dead cells among all adhering bacteria were found between Prom (23.7%) and Pt (29.1%). Ectopic solitary epithelial cells from the oral mucosa – strongly adhering to the substratum – were found on each Prom specimen, but not on any of the Pt surfaces.Conclusions: Initial bacterial adhesion to differently textured titanium surfaces is primarily influenced by Ra, whereas the influence of SFE seems to be of only minor importance. Therefore, the micro‐structured parts of an implant that are exposed to the oral cavity should be highly polished to prevent plaque accumulation. Both tested fluorometric techniques proved to be highly sensitive and reproducible in the quantification of biofilm formation on titanium implant surfaces. To cite this article: Bürgers R, Gerlach T, Hahnel S, Schwarz F, Handel G, Gosau M. In vivo and in vitro biofilm formation on two different titanium implant surfaces. Clin. Oral Impl. Res. 21, 2010; 156–164 doi: 10.1111/j.1600‐0501.2009.01815.x
- 11 January 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (2) , 156-164
In vivo and in vitro biofilm formation on two different titanium implant surfaces
Objectives: The aim of the present in vitro and human in vivo study was twofold: first, to evaluate the initial biofilm formation on different titanium implant surfaces by means of two highly sensitive fluorescent techniques and, second, to correlate these findings to different surface properties.Materials and methods: In vivo biofilm formation was induced on purely machined (Pt) and on sand‐blasted and acid‐etched titanium (Prom) specimens, which were mounted buccally on individual splints and worn by six study participants for 12 h. In vitro bacterial adhesion was also investigated after incubation with Streptococcus sanguinis suspension (37°C, 2 h). Adherent bacteria were quantified by the following fluorescence techniques: Resazurin staining in combination with an automated fluorescence reader or live/dead cell labeling and fluorescence microscopy. Surface roughness (Ra) was determined with a perthometer, and surface free energy (SFE) was measured with a goniometer.Results: Prom showed a significantly higher median Ra (0.95 μm) and a significantly lower median SFE (18.3 mJ/m2) than Pt (Ra=0.15 μm; SFE=39.6 mJ/m2). The in vitro and in vivo tests showed a significantly higher bacterial adhesion to Prom than to Pt, and the initial biofilm formation on Pt corresponded to the circular surface modifications on the machined substratum. Both observations may be attributed to the predominant influence of surface roughness on bacterial adhesion. No significant differences in the percentage of dead cells among all adhering bacteria were found between Prom (23.7%) and Pt (29.1%). Ectopic solitary epithelial cells from the oral mucosa – strongly adhering to the substratum – were found on each Prom specimen, but not on any of the Pt surfaces.Conclusions: Initial bacterial adhesion to differently textured titanium surfaces is primarily influenced by Ra, whereas the influence of SFE seems to be of only minor importance. Therefore, the micro‐structured parts of an implant that are exposed to the oral cavity should be highly polished to prevent plaque accumulation. Both tested fluorometric techniques proved to be highly sensitive and reproducible in the quantification of biofilm formation on titanium implant surfaces. To cite this article: Bürgers R, Gerlach T, Hahnel S, Schwarz F, Handel G, Gosau M. In vivo and in vitro biofilm formation on two different titanium implant surfaces. Clin. Oral Impl. Res. 21, 2010; 156–164 doi: 10.1111/j.1600‐0501.2009.01815.x
- 1 June 2009
- Published by Elsevier in Archives of Oral Biology
- Vol. 54 (6) , 595-601
The anti-adherence activity and bactericidal effect of microparticulate silver additives in composite resin materials
- 1 June 2009
- Published by Elsevier in Archives of Oral Biology
- Vol. 54 (6) , 595-601
The anti-adherence activity and bactericidal effect of microparticulate silver additives in composite resin materials
- 21 February 2009
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 13 (4) , 419-426
Effects of aging on surface properties and adhesion of Streptococcus mutans on various fissure sealants
The aim of the present study was the quantification of Streptococcus mutans adhesion on ten widely used pit and fissure sealant materials and the correlation of these findings to surface roughness (R a) and surface free energy (SFE). Additionally, changes in streptococcal adhesion and surface parameters after water immersion and artificial aging have been investigated. Circular specimens of ten fissure sealants (seven resin-based composites, two glass ionomers, and one compomer) were made and polished. Surface roughness was determined by perthometer and SFE by goniometer measurements. Sealant materials were incubated with S. mutans suspension (2.5 h, 37°C), and adhering bacteria were quantified by using a biofluorescence assay in combination with an automated plate reader. Surface properties and S. mutans adhesion were measured prior to and after water immersion after 1 and 6 months and after additional thermocycling (5,000 cycles; 5°C/55°C). The tested sealants showed significant differences in S. mutans adhesion prior to and after the applied aging procedures. Aging resulted in slight increases (mostly S. mutans was reduced after aging, which may be related to the decline in SFEs.
- 21 February 2009
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 13 (4) , 419-426
Effects of aging on surface properties and adhesion of Streptococcus mutans on various fissure sealants
The aim of the present study was the quantification of Streptococcus mutans adhesion on ten widely used pit and fissure sealant materials and the correlation of these findings to surface roughness (R a) and surface free energy (SFE). Additionally, changes in streptococcal adhesion and surface parameters after water immersion and artificial aging have been investigated. Circular specimens of ten fissure sealants (seven resin-based composites, two glass ionomers, and one compomer) were made and polished. Surface roughness was determined by perthometer and SFE by goniometer measurements. Sealant materials were incubated with S. mutans suspension (2.5 h, 37°C), and adhering bacteria were quantified by using a biofluorescence assay in combination with an automated plate reader. Surface properties and S. mutans adhesion were measured prior to and after water immersion after 1 and 6 months and after additional thermocycling (5,000 cycles; 5°C/55°C). The tested sealants showed significant differences in S. mutans adhesion prior to and after the applied aging procedures. Aging resulted in slight increases (mostly S. mutans was reduced after aging, which may be related to the decline in SFEs.
- 23 September 2008
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 13 (3) , 293-299
Candida albicans adhesion to composite resin materials
The adhesion of Candida albicans to dental restorative materials in the human oral cavity may promote the occurrence of oral candidosis. This study aimed to compare the susceptibility of 14 commonly used composite resin materials (two compomers, one ormocer, one novel silorane, and ten conventional hybrid composites) to adhere Candida albicans. Differences in the amount of adhering fungi should be related to surface roughness, hydrophobicity, and the type of matrix. Cylindrical specimens of each material were made according to the manufacturers’ instructions. Surface roughness R a was assessed by perthometer measurements and the degree of hydrophobicity by computerized contact angle analysis. Specimens were incubated with a reference strain of C. albicans (DMSZ 1386), and adhering fungi were quantified by using a bioluminometric assay in combination with an automated plate reader. Statistical differences were analyzed by the Kruskal–Wallis test and Mann–Whitney U test. Spearman’s rank correlation coefficients were calculated to assess correlations. Median R a of the tested composite resin materials ranged between 0.04 and 0.23 μm, median contact angles between 69.2° and 86.9°. The two compomers and the ormocer showed lower luminescence intensities indicating less adhesion of fungi than all tested conventional hybrid composites. No conclusive correlation was found between surface roughness, hydrophobicity, and the amount of adhering C. albicans.
- 23 September 2008
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 13 (3) , 293-299
Candida albicans adhesion to composite resin materials
The adhesion of Candida albicans to dental restorative materials in the human oral cavity may promote the occurrence of oral candidosis. This study aimed to compare the susceptibility of 14 commonly used composite resin materials (two compomers, one ormocer, one novel silorane, and ten conventional hybrid composites) to adhere Candida albicans. Differences in the amount of adhering fungi should be related to surface roughness, hydrophobicity, and the type of matrix. Cylindrical specimens of each material were made according to the manufacturers’ instructions. Surface roughness R a was assessed by perthometer measurements and the degree of hydrophobicity by computerized contact angle analysis. Specimens were incubated with a reference strain of C. albicans (DMSZ 1386), and adhering fungi were quantified by using a bioluminometric assay in combination with an automated plate reader. Statistical differences were analyzed by the Kruskal–Wallis test and Mann–Whitney U test. Spearman’s rank correlation coefficients were calculated to assess correlations. Median R a of the tested composite resin materials ranged between 0.04 and 0.23 μm, median contact angles between 69.2° and 86.9°. The two compomers and the ormocer showed lower luminescence intensities indicating less adhesion of fungi than all tested conventional hybrid composites. No conclusive correlation was found between surface roughness, hydrophobicity, and the amount of adhering C. albicans.