Martha Vallejo Mar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martha Vallejo Mar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
E Edmund Kim
2 shared publicationsDonald A Podoloff
1 shared publicationHomer A Macapinlac
1 shared publicationRenee L. Dickinson
1 shared publicationRichard E. Wendt
1 shared publicationScott A Miller
1 shared publication
Latest Publications
- Open Access
- 15 May 2008
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 36 (2) , 82-87
Optimal 57Co Flood Source Activity and Acquisition Time for Lymphoscintigraphy Localization Images
We evaluated different 57Co flood source activities and acquisition times to obtain an optimal localization image for breast lymphoscintigraphy that would adequately outline the body and allow detection of nodes seen on the emission scan while minimizing unnecessary radiation exposure to the patient. Methods: An anthropomorphic thorax breast phantom representing an average-size patient was used to simulate nodes on a breast lymphoscintigraphy scan. The activities in the nodes at the time of acquisition ranged from 37 to 185 kBq (1–5 μCi). Four experiments were performed, consisting of 10-min emission and 3-min localization images. Anterior, posterior, and right and left lateral views of the thorax phantom were acquired, using each of 5 different 57Co flood sources with activities ranging from 37 to 269 MBq (1.0–7.26 mCi). Ten 1-min localization images for each source were acquired and compared for quality. Three-minute localization images for 2 phantom thicknesses of 10 and 20 cm were acquired to determine the contrast-to-noise ratio for each 57Co source. The total exposure was measured using an ion chamber survey meter. Results: All sources allowed visualization of the lymphatic nodes in acquisitions as short as 3 min. Images using the 126-MBq (3.41-mCi) source demonstrated an adequate body outline along with visualization of all nodes seen on the emission image. The 37-MBq (1.0-mCi) source did not provide sufficient definition of the body outline, whereas the hotter sources decreased node visualization by increasing the background around the nodes at the same time that they increased the patient exposure. Node activity of 37 kBq (1 μCi) became undetectable on the anterior localization images yet was still visible on the lateral image because of greater attenuation of 57Co photons. The estimated dose rate from the 57Co sheet sources was 0.641 μSv/MBq/h. Conclusion: Acquiring a 3-min localization scan using a 126-MBq (3.41-mCi) source provided the best combination of clear-body outline and visualization of all nodes seen on the emission image. The estimated dose to the patient from the 126-MBq (3.41-mCi) sheet source was very low (8.7 μSv for unilateral and 13.1 μSv for bilateral). Node detectability decreased in localization images acquired using 57Co sources of higher activity. This effect would be more pronounced in lymphoscintigrams of thin patients compared with those of patients of average thickness.
- 15 May 2008
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 36 (2) , 82-87
Open AccessOptimal 57Co Flood Source Activity and Acquisition Time for Lymphoscintigraphy Localization Images
We evaluated different 57Co flood source activities and acquisition times to obtain an optimal localization image for breast lymphoscintigraphy that would adequately outline the body and allow detection of nodes seen on the emission scan while minimizing unnecessary radiation exposure to the patient. Methods: An anthropomorphic thorax breast phantom representing an average-size patient was used to simulate nodes on a breast lymphoscintigraphy scan. The activities in the nodes at the time of acquisition ranged from 37 to 185 kBq (1–5 μCi). Four experiments were performed, consisting of 10-min emission and 3-min localization images. Anterior, posterior, and right and left lateral views of the thorax phantom were acquired, using each of 5 different 57Co flood sources with activities ranging from 37 to 269 MBq (1.0–7.26 mCi). Ten 1-min localization images for each source were acquired and compared for quality. Three-minute localization images for 2 phantom thicknesses of 10 and 20 cm were acquired to determine the contrast-to-noise ratio for each 57Co source. The total exposure was measured using an ion chamber survey meter. Results: All sources allowed visualization of the lymphatic nodes in acquisitions as short as 3 min. Images using the 126-MBq (3.41-mCi) source demonstrated an adequate body outline along with visualization of all nodes seen on the emission image. The 37-MBq (1.0-mCi) source did not provide sufficient definition of the body outline, whereas the hotter sources decreased node visualization by increasing the background around the nodes at the same time that they increased the patient exposure. Node activity of 37 kBq (1 μCi) became undetectable on the anterior localization images yet was still visible on the lateral image because of greater attenuation of 57Co photons. The estimated dose rate from the 57Co sheet sources was 0.641 μSv/MBq/h. Conclusion: Acquiring a 3-min localization scan using a 126-MBq (3.41-mCi) source provided the best combination of clear-body outline and visualization of all nodes seen on the emission image. The estimated dose to the patient from the 126-MBq (3.41-mCi) sheet source was very low (8.7 μSv for unilateral and 13.1 μSv for bilateral). Node detectability decreased in localization images acquired using 57Co sources of higher activity. This effect would be more pronounced in lymphoscintigrams of thin patients compared with those of patients of average thickness.
- 1 March 2007
- Vol. 35 (1) , 10-6; quiz 17
Evaluation and localization of lymphatic drainage and sentinel lymph nodes in patients with head and neck melanomas by hybrid SPECT/CT lymphoscintigraphic imaging.
In patients with head and neck tumors, preoperative lymphoscintigraphy can be used to map lymphatic drainage patterns and identify sentinel lymph nodes. However, it is very difficult to determine the exact locations of head and neck sentinel nodes on preoperative lymphoscintigraphy without the use of anatomic landmarks. Lymph nodes in the head and neck are grouped into 7 regions, or levels, on the basis of anatomic landmarks. In patients undergoing standard lymphoscintigraphy, obtaining lateral marker images that show important anatomic landmarks can help with the localization of sentinel nodes. However, technical problems often render marker images of little or no use. Hybrid SPECT/CT lymphoscintigraphic imaging facilitates the localization of sentinel nodes by reliably showing the relationships between sentinel nodes and important anatomic structures. After reading this article, the reader should understand the lymph node level classification system for head and neck melanomas, be able to describe the technique used for the imaging of sentinel nodes in the head and neck region, and be able to demonstrate how SPECT/CT lymphoscintigraphic imaging can enable precise sentinel node localization and thus help to ensure minimal dissection.
- 1 March 2007
- Vol. 35 (1) , 10-6; quiz 17
Evaluation and localization of lymphatic drainage and sentinel lymph nodes in patients with head and neck melanomas by hybrid SPECT/CT lymphoscintigraphic imaging.
In patients with head and neck tumors, preoperative lymphoscintigraphy can be used to map lymphatic drainage patterns and identify sentinel lymph nodes. However, it is very difficult to determine the exact locations of head and neck sentinel nodes on preoperative lymphoscintigraphy without the use of anatomic landmarks. Lymph nodes in the head and neck are grouped into 7 regions, or levels, on the basis of anatomic landmarks. In patients undergoing standard lymphoscintigraphy, obtaining lateral marker images that show important anatomic landmarks can help with the localization of sentinel nodes. However, technical problems often render marker images of little or no use. Hybrid SPECT/CT lymphoscintigraphic imaging facilitates the localization of sentinel nodes by reliably showing the relationships between sentinel nodes and important anatomic structures. After reading this article, the reader should understand the lymph node level classification system for head and neck melanomas, be able to describe the technique used for the imaging of sentinel nodes in the head and neck region, and be able to demonstrate how SPECT/CT lymphoscintigraphic imaging can enable precise sentinel node localization and thus help to ensure minimal dissection.
- 1 March 2002
- Vol. 30 (1) , 12-7
Whole-body lymphoscintigraphy using transmission scans.
Our objective was to show the advantages of performing whole-body lymphoscintigraphy using transmission sources. This technique should decrease scanning time, help locate the sentinel lymph node, and decrease radiation exposure to the technologist. Twenty patients with proven melanoma received 18.5 MBq (0.5 mCi) filtered (0.22 microm) (99m)Tc-sulfur colloid in a 0.2-mL volume, administered as multiple intradermal or subcutaneous injections around the known melanoma lesion or scar. All 20 patients underwent serial static imaging immediately after the injection, along with whole-body scanning after the static imaging. The static emission images were acquired for 5 min and the transmission images for 1 min using a 256 x 256 matrix. The whole-body transmission scans were acquired after the whole-body emission scans. The transmission scans were obtained with the same parameters as the emission scans, with the addition of placement of a (57)Co sheet source on one of the detectors of the large-field-of-view dual-head camera. The planar static axial images (transmission, emission) were compared with the whole-body images (transmission, emission) to determine whether the same number of lymph nodes was visualized with each technique. Posterior outlines were obtained through computer manipulation of anterior transmission images. In all 20 patients, the number of lymph nodes seen on the static images was the same as that seen on the whole-body emission and transmission images. The whole-body emission and transmission scanning time was an average of 30 min less than the time required to acquire the serial static images. The anatomic location of the sentinel lymph node is seen more easily on whole-body images, both anterior transmission and posterior transmission, than on planar static images. Whole-body emission and transmission imaging decreased scanning time and thus improved patient comfort and throughput. Technologists received less radiation exposure when handling the (57)Co source only twice during whole-body imaging, as opposed to several times during static imaging.
- 1 March 2002
- Vol. 30 (1) , 12-7
Whole-body lymphoscintigraphy using transmission scans.
Our objective was to show the advantages of performing whole-body lymphoscintigraphy using transmission sources. This technique should decrease scanning time, help locate the sentinel lymph node, and decrease radiation exposure to the technologist. Twenty patients with proven melanoma received 18.5 MBq (0.5 mCi) filtered (0.22 microm) (99m)Tc-sulfur colloid in a 0.2-mL volume, administered as multiple intradermal or subcutaneous injections around the known melanoma lesion or scar. All 20 patients underwent serial static imaging immediately after the injection, along with whole-body scanning after the static imaging. The static emission images were acquired for 5 min and the transmission images for 1 min using a 256 x 256 matrix. The whole-body transmission scans were acquired after the whole-body emission scans. The transmission scans were obtained with the same parameters as the emission scans, with the addition of placement of a (57)Co sheet source on one of the detectors of the large-field-of-view dual-head camera. The planar static axial images (transmission, emission) were compared with the whole-body images (transmission, emission) to determine whether the same number of lymph nodes was visualized with each technique. Posterior outlines were obtained through computer manipulation of anterior transmission images. In all 20 patients, the number of lymph nodes seen on the static images was the same as that seen on the whole-body emission and transmission images. The whole-body emission and transmission scanning time was an average of 30 min less than the time required to acquire the serial static images. The anatomic location of the sentinel lymph node is seen more easily on whole-body images, both anterior transmission and posterior transmission, than on planar static images. Whole-body emission and transmission imaging decreased scanning time and thus improved patient comfort and throughput. Technologists received less radiation exposure when handling the (57)Co source only twice during whole-body imaging, as opposed to several times during static imaging.