Akio Kawamura
Research Subjects
Research Interests
Akio Kawamura has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Sachio Kuribayashi
Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
3 shared publicationsSatoshi Ogawa
Division of Cardiology, Department of Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
3 shared publications- Ayaka Endo
Keio University School of Medicine, Tokyo, Japan
2 shared publications David E. Gossman
Department of Cardiovascular Medicine, Lahey Clinic Medical Center, Burlington
2 shared publications- Keiichi Fukuda
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
2 shared publications - Kentaro Hayashida
Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
2 shared publications
Latest Publications
- 14 April 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 174 (2) , e54-e56
Coexistence of two distinct fascinating cardiovascular disorders: Heterotaxy syndrome with left ventricular non-compaction and vasospastic angina
- 14 April 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 174 (2) , e54-e56
Coexistence of two distinct fascinating cardiovascular disorders: Heterotaxy syndrome with left ventricular non-compaction and vasospastic angina
- 1 August 2013
- Vol. 25 (8) , E167-8
Autopsy findings of Amplatzer septal occluder at 5 months after closure of atrial septal defect: how long does it take to be endothelialized?
An 83-year-old man died of aspiration pneumonia 5 months after closure of atrial septal defect (ASD) with an Amplatzer atrial septal defect occluder (ASO). At autopsy, the device was scarcely covered by the endothelium. After percutaneous ASD closure, 6-month course of antiplatelet therapy and prophylaxis for endocarditis are recommended. However, the 6-month duration may not be sufficient for some patients. More data are required to clarify how long it takes for the ASO device to be endothelialized in the human body and to determine predictors of poor endothelialization.
- 1 August 2013
- Vol. 25 (8) , E167-8
Autopsy findings of Amplatzer septal occluder at 5 months after closure of atrial septal defect: how long does it take to be endothelialized?
An 83-year-old man died of aspiration pneumonia 5 months after closure of atrial septal defect (ASD) with an Amplatzer atrial septal defect occluder (ASO). At autopsy, the device was scarcely covered by the endothelium. After percutaneous ASD closure, 6-month course of antiplatelet therapy and prophylaxis for endocarditis are recommended. However, the 6-month duration may not be sufficient for some patients. More data are required to clarify how long it takes for the ASO device to be endothelialized in the human body and to determine predictors of poor endothelialization.
- 1 June 2012
- Vol. 24 (6) , E115-8
Left main trunk perforation sealed by 90 second perfusion balloon inflation.
Coronary perforation is a rare but serious complication of percutaneous coronary intervention. In our case, kissing balloon technique caused the perforation. We took care of balloon diameter and inflation pressure, but we did not consider that the proximal lumen could take elliptical rather than circular shape. Then perforation occurred at the proximal side of the kissing balloon technique. Fortunately, we could achieve hemostasis successfully by 90 seconds perfusion balloon inflation. You must consider not only balloon diameter and inflation pressure but also balloon form as an important safety factor for the kissing balloon technique on the left main trunk.
- 1 June 2012
- Vol. 24 (6) , E115-8
Left main trunk perforation sealed by 90 second perfusion balloon inflation.
Coronary perforation is a rare but serious complication of percutaneous coronary intervention. In our case, kissing balloon technique caused the perforation. We took care of balloon diameter and inflation pressure, but we did not consider that the proximal lumen could take elliptical rather than circular shape. Then perforation occurred at the proximal side of the kissing balloon technique. Fortunately, we could achieve hemostasis successfully by 90 seconds perfusion balloon inflation. You must consider not only balloon diameter and inflation pressure but also balloon form as an important safety factor for the kissing balloon technique on the left main trunk.
- 7 July 2011
- Published by Springer Nature in Heart and Vessels
- Vol. 27 (3) , 331-336
Successful percutaneous coil embolization of coronary–pulmonary, –carotid, and –internal mammary artery fistulas
We herein describe a 57-year-old man with coronary–pulmonary artery fistulas that had abnormal connections between the left common carotid artery and the left internal mammary artery. The patient was treated with percutaneous coil embolization using antegrade (via the coronary artery) and retrograde (via the pulmonary artery) approaches. Coronary artery fistulas have diverse anatomical variations, and it is important to thoroughly evaluate the anatomy before beginning any mode of treatment, surgical or endovascular. In the case reported herein, multislice computed tomography played a pivotal role in the preprocedure evaluation.
- 7 July 2011
- Published by Springer Nature in Heart and Vessels
- Vol. 27 (3) , 331-336
Successful percutaneous coil embolization of coronary–pulmonary, –carotid, and –internal mammary artery fistulas
We herein describe a 57-year-old man with coronary–pulmonary artery fistulas that had abnormal connections between the left common carotid artery and the left internal mammary artery. The patient was treated with percutaneous coil embolization using antegrade (via the coronary artery) and retrograde (via the pulmonary artery) approaches. Coronary artery fistulas have diverse anatomical variations, and it is important to thoroughly evaluate the anatomy before beginning any mode of treatment, surgical or endovascular. In the case reported herein, multislice computed tomography played a pivotal role in the preprocedure evaluation.
- 25 November 2010
- Published by Elsevier in International Journal of Cardiology
- Vol. 156 (1) , 76-79
Effect of preoperative evaluation by multidetector computed tomography in percutaneous coronary interventions of chronic total occlusions
- 25 November 2010
- Published by Elsevier in International Journal of Cardiology
- Vol. 156 (1) , 76-79
Effect of preoperative evaluation by multidetector computed tomography in percutaneous coronary interventions of chronic total occlusions
- 1 May 2009
- Vol. 21 (5) , E84-6
Percutaneous revascularization of chronic total occlusion of left anterior descending artery using contralateral injection via isolated conus artery.
A 74-year-old male underwent cardiac catheterization that revealed a chronic total occlusion of the proximal left anterior descending coronary artery (LAD). The right coronary artery provided only faint collateral circulation to the LAD. Multislice computed tomography (MDCT) disclosed that a conus artery took off directly from the aorta and provided good collateral circulation to the LAD. Percutaneous coronary intervention of the LAD was successfully performed using contralateral injection via the isolated conus artery. Whenever sufficient collateral filling is not visualized in a chronically occluded LAD, an isolated conus artery should be considered. MDCT is a helpful tool in this setting.
- 1 May 2009
- Vol. 21 (5) , E84-6
Percutaneous revascularization of chronic total occlusion of left anterior descending artery using contralateral injection via isolated conus artery.
A 74-year-old male underwent cardiac catheterization that revealed a chronic total occlusion of the proximal left anterior descending coronary artery (LAD). The right coronary artery provided only faint collateral circulation to the LAD. Multislice computed tomography (MDCT) disclosed that a conus artery took off directly from the aorta and provided good collateral circulation to the LAD. Percutaneous coronary intervention of the LAD was successfully performed using contralateral injection via the isolated conus artery. Whenever sufficient collateral filling is not visualized in a chronically occluded LAD, an isolated conus artery should be considered. MDCT is a helpful tool in this setting.
- Open Access
- 1 December 2008
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 86 (6) , 1987-1989
Extrinsic Compression of the Left Main Coronary Artery by Atrial Septal Defect
- 1 December 2008
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 86 (6) , 1987-1989
Open AccessExtrinsic Compression of the Left Main Coronary Artery by Atrial Septal Defect
- Open Access
- 1 January 2007
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 71 (9) , 1370-1375
Stroke Complicating Percutaneous Coronary Intervention in Patients With Acute Myocardial Infarction
Background Stroke associated with percutaneous coronary intervention (PCI) is a tragic complication. Despite advances in the practice of PCI, the incidence of stroke complicating PCI has not changed over the decades. The objective of the present study was to evaluate incidence and correlates of stroke occurring in patients with myocardial infarction (MI) undergoing PCI. Methods and Results Stroke was defined as the presence of any new focal neurological deficit lasting ≥24 h that occurred anytime during or after PCI until discharge. In 2,281 consecutive patients with PCIs for non-ST-elevation MI, or ST-elevation MI (STEMI), 20 strokes were identified (0.88%). Strokes were ischemic in 95%. On multivariate analyses, ejection fraction ≤30% (odds ratio =4.3, p=0.003) was the only independent predictor for stroke. In patients who developed stroke within 24 h of PCI, PCI of vein grafts was more frequent, and use of glycoprotein IIb/IIIa inhibitor was less frequent. Those patients tended to present late in the course of MI. Stroke found more than 24 h after PCI was related to diabetes, higher serum creatinine, lower ejection fraction, anterior wall STEMI and emergency use of intra-aortic balloon pumps. Conclusions Low ejection fraction was the only independent predictor for stroke, but risk factors for periprocedural stroke are different from those of stroke occurring more than 24 h after PCI. Upstream use of glycoprotein IIb/IIIa inhibitor might decrease the risk of periprocedural stroke. (Circ J 2007; 71: 1370 - 1375)
- 1 January 2007
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 71 (9) , 1370-1375
Open AccessStroke Complicating Percutaneous Coronary Intervention in Patients With Acute Myocardial Infarction
Background Stroke associated with percutaneous coronary intervention (PCI) is a tragic complication. Despite advances in the practice of PCI, the incidence of stroke complicating PCI has not changed over the decades. The objective of the present study was to evaluate incidence and correlates of stroke occurring in patients with myocardial infarction (MI) undergoing PCI. Methods and Results Stroke was defined as the presence of any new focal neurological deficit lasting ≥24 h that occurred anytime during or after PCI until discharge. In 2,281 consecutive patients with PCIs for non-ST-elevation MI, or ST-elevation MI (STEMI), 20 strokes were identified (0.88%). Strokes were ischemic in 95%. On multivariate analyses, ejection fraction ≤30% (odds ratio =4.3, p=0.003) was the only independent predictor for stroke. In patients who developed stroke within 24 h of PCI, PCI of vein grafts was more frequent, and use of glycoprotein IIb/IIIa inhibitor was less frequent. Those patients tended to present late in the course of MI. Stroke found more than 24 h after PCI was related to diabetes, higher serum creatinine, lower ejection fraction, anterior wall STEMI and emergency use of intra-aortic balloon pumps. Conclusions Low ejection fraction was the only independent predictor for stroke, but risk factors for periprocedural stroke are different from those of stroke occurring more than 24 h after PCI. Upstream use of glycoprotein IIb/IIIa inhibitor might decrease the risk of periprocedural stroke. (Circ J 2007; 71: 1370 - 1375)
- 4 July 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (2) , 267-270
Retroperitoneal hemorrhage from inferior epigastric artery: Value of femoral angiography for detection and management
Laceration of the inferior epigastric artery during cardiac catheterization is under‐reported in the literature, but it is a serious complication leading to retroperitoneal hemorrhage and even death. We report on two cases of retroperitoneal bleeding from unintentional puncture of the inferior epigastric artery during cardiac catheterization. Femoral angiography is a valuable tool to promptly recognize this complication.
- 4 July 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (2) , 267-270
Retroperitoneal hemorrhage from inferior epigastric artery: Value of femoral angiography for detection and management
Laceration of the inferior epigastric artery during cardiac catheterization is under‐reported in the literature, but it is a serious complication leading to retroperitoneal hemorrhage and even death. We report on two cases of retroperitoneal bleeding from unintentional puncture of the inferior epigastric artery during cardiac catheterization. Femoral angiography is a valuable tool to promptly recognize this complication.
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 239-243
Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture
During treatment for in‐stent restenosis, entrapment of cutting balloon occurred because of the blade fracture. Removal of the balloon caused stent extraction, inducing acute occlusion of the coronary artery. Application of cutting balloon for in‐stent restenosis requires every caution against such type of complications. Cathet Cardiovasc Intervent 2002;57:239–243.
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 239-243
Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture
During treatment for in‐stent restenosis, entrapment of cutting balloon occurred because of the blade fracture. Removal of the balloon caused stent extraction, inducing acute occlusion of the coronary artery. Application of cutting balloon for in‐stent restenosis requires every caution against such type of complications. Cathet Cardiovasc Intervent 2002;57:239–243.