Imre Fejes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Imre Fejes has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
A. Pál
2 shared publicationsAttila Pál
Department of Obstetrics and Gynaecology, Faculty of Medicine, University of Szeged, Hungary
2 shared publicationsJ. Daru
2 shared publicationsJ. Szöllősi
2 shared publicationsL. Kovács
2 shared publicationsMárta Janáky
Department of Ophthalmology, University of Szeged, Szeged, Hungary
2 shared publications
Latest Publications
- 1 July 2020
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 46 (4) , e27-e29
Keratitis Caused by Candida parapsilosis and Subsequent Corynebacterium macginleyi Infection: Case Report and Short Review
Keratitis due to Candida parapsilosis or Corynebacterium macginleyi is uncommon. We present a patient with several risk factors who suffered two subsequent corneal infections caused by these pathogens and healed with topical conservative therapy. The important factor was the early detection of infection. Fluconazole solution administered topically as eye drops combined with regular debridement proved in this case a successful alternative to systemic antifungal treatment. With a perceived recurrence of the keratitis, one must take into account the involvement of other pathogens present. The previous use of an antifungal solution other than a conventional eye drop could be an additional risk factor for a second bacterial infection, but the benefits should still rule in favor of such a treatment.
- 1 July 2020
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 46 (4) , e27-e29
Keratitis Caused by Candida parapsilosis and Subsequent Corynebacterium macginleyi Infection: Case Report and Short Review
Keratitis due to Candida parapsilosis or Corynebacterium macginleyi is uncommon. We present a patient with several risk factors who suffered two subsequent corneal infections caused by these pathogens and healed with topical conservative therapy. The important factor was the early detection of infection. Fluconazole solution administered topically as eye drops combined with regular debridement proved in this case a successful alternative to systemic antifungal treatment. With a perceived recurrence of the keratitis, one must take into account the involvement of other pathogens present. The previous use of an antifungal solution other than a conventional eye drop could be an additional risk factor for a second bacterial infection, but the benefits should still rule in favor of such a treatment.
- 10 July 2014
- Published by Wiley in Acta Ophthalmologica
- Vol. 93 (4) , e311-3
The air temperature may affect ophthalmologic emergency attendances
- 10 July 2014
- Published by Wiley in Acta Ophthalmologica
- Vol. 93 (4) , e311-3
The air temperature may affect ophthalmologic emergency attendances
- 1 April 2014
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (4) , 472-476
Interocular Amplitude and Latency Differences of Pattern ERG and Pattern VEP Parameters
Purpose: To determine the normal interocular differences in amplitudes and peak times of the pattern electroretinograms (PERGs) and pattern visual evoked potentials (PVEPs) and to investigate whether the PERG and PVEP parameters correspond in lateral dominance or whether the eye‐side distributions of the functional parameters are similar. Methods: The PERGs and PVEPs were recorded in healthy subjects (N = 77) according to the standards of the International Society for Clinical Electrophysiology of Vision, with the modification of the check size of the PERG to 0.5 degrees. This allows stimulation of the macular ganglion cells and their corresponding visual pathways in healthy subjects. Results: Comparison of the averaged higher and lower response amplitudes and the shorter and longer response peak times showed significant differences (p < 0.001) in both the PERG and the PVEP parameters (median [5 to 95%]): the P50 (1.92% [0 to 5.48%]) and N95 (2.06% [0 to 13.95%]) peak times and the P50 (11.82% [1.32 to 29.93%) and N95 (9.45% [1.17 to 30.38%]) amplitudes of the PERGs and the P100 (1.04% [0 to 4.15%]) and N135 (1.96% [0 to 12.36%]) peak times and the P100 (9.86% [1.26 to 29.76%]) and N135 (11.19% [1.18 to 29.99%]) amplitudes of the PVEPs. No significant correlation was found concerning the eye dominance of the PERG and PVEP parameters. Conclusions: Our results reveal a significant interocular difference on PERG and PVEP recording, but this could not be ascribed to the anatomy of the retina and related visual pathways. If the difference between the eyes is not taken into account, misinterpretation may occur in a pathological process.
- 1 April 2014
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (4) , 472-476
Interocular Amplitude and Latency Differences of Pattern ERG and Pattern VEP Parameters
Purpose: To determine the normal interocular differences in amplitudes and peak times of the pattern electroretinograms (PERGs) and pattern visual evoked potentials (PVEPs) and to investigate whether the PERG and PVEP parameters correspond in lateral dominance or whether the eye‐side distributions of the functional parameters are similar. Methods: The PERGs and PVEPs were recorded in healthy subjects (N = 77) according to the standards of the International Society for Clinical Electrophysiology of Vision, with the modification of the check size of the PERG to 0.5 degrees. This allows stimulation of the macular ganglion cells and their corresponding visual pathways in healthy subjects. Results: Comparison of the averaged higher and lower response amplitudes and the shorter and longer response peak times showed significant differences (p < 0.001) in both the PERG and the PVEP parameters (median [5 to 95%]): the P50 (1.92% [0 to 5.48%]) and N95 (2.06% [0 to 13.95%]) peak times and the P50 (11.82% [1.32 to 29.93%) and N95 (9.45% [1.17 to 30.38%]) amplitudes of the PERGs and the P100 (1.04% [0 to 4.15%]) and N135 (1.96% [0 to 12.36%]) peak times and the P100 (9.86% [1.26 to 29.76%]) and N135 (11.19% [1.18 to 29.99%]) amplitudes of the PVEPs. No significant correlation was found concerning the eye dominance of the PERG and PVEP parameters. Conclusions: Our results reveal a significant interocular difference on PERG and PVEP recording, but this could not be ascribed to the anatomy of the retina and related visual pathways. If the difference between the eyes is not taken into account, misinterpretation may occur in a pathological process.
- 1 December 2012
- Published by Springer Nature in Infection
- Vol. 41 (1) , 267-270
Clostridium septicum gas gangrene in the orbit: a case report
Our report presents a case of Clostridium septicum gas gangrene in an unusual, orbital localization. The predisposing factors are typical: colon tumour and lymphatic malignancy. Most probably bacteria from the intestinal flora entered the bloodstream through the compromised intestinal wall and settled in the orbit resulting in the development of an abscess containing gas. At the site of the gas gangrene, an indolent B cell lymphoma was present. After surgery and antibiotic treatment, the patient healed from the C. septicum infection; but subsequently died as a consequence of the tumour.
- 1 December 2012
- Published by Springer Nature in Infection
- Vol. 41 (1) , 267-270
Clostridium septicum gas gangrene in the orbit: a case report
Our report presents a case of Clostridium septicum gas gangrene in an unusual, orbital localization. The predisposing factors are typical: colon tumour and lymphatic malignancy. Most probably bacteria from the intestinal flora entered the bloodstream through the compromised intestinal wall and settled in the orbit resulting in the development of an abscess containing gas. At the site of the gas gangrene, an indolent B cell lymphoma was present. After surgery and antibiotic treatment, the patient healed from the C. septicum infection; but subsequently died as a consequence of the tumour.
- 1 January 2007
- Published by Taylor & Francis in Archives of Andrology
- Vol. 53 (2) , 105-106
Hypothesis: Safety of Using Mobile Phones on Male Fertility
- 1 January 2007
- Published by Taylor & Francis in Archives of Andrology
- Vol. 53 (2) , 105-106
Hypothesis: Safety of Using Mobile Phones on Male Fertility
- 1 August 2006
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 85 (8) , 993-996
A boy or a girl? A Hungarian survey regarding gender selection
Background. Infertile Hungarian couples were surveyed with regard to their opinion of preconception gender selection by the separation of X‐ and Y‐bearing sperm populations. Methods. Self‐completion of a questionnaire. Group 1: subjects presenting for infertility examination; Group 2: presenting for homologous intrauterine insemination. Results. As concerns the gender of the firstborn, 13.8% of those in Group 1 preferred a boy and 10.3% a girl, while 75.9% had no preference. The male preference was higher in Group 2: 33.3% preferred a boy and 7.4% a girl while 59.3% had no preference (χ2, p2, pConclusions. Our findings revealed a trend to preference for firstborn males, although couples wishing more than one offspring prefer equal numbers of male and female children. The utilization of preconception gender selection, therefore, would not seem to appreciably affect the natural male/female ratio. Genetic indications exert significant effects on the decision regarding sex selection procedures.
- 1 August 2006
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 85 (8) , 993-996
A boy or a girl? A Hungarian survey regarding gender selection
Background. Infertile Hungarian couples were surveyed with regard to their opinion of preconception gender selection by the separation of X‐ and Y‐bearing sperm populations. Methods. Self‐completion of a questionnaire. Group 1: subjects presenting for infertility examination; Group 2: presenting for homologous intrauterine insemination. Results. As concerns the gender of the firstborn, 13.8% of those in Group 1 preferred a boy and 10.3% a girl, while 75.9% had no preference. The male preference was higher in Group 2: 33.3% preferred a boy and 7.4% a girl while 59.3% had no preference (χ2, p2, pConclusions. Our findings revealed a trend to preference for firstborn males, although couples wishing more than one offspring prefer equal numbers of male and female children. The utilization of preconception gender selection, therefore, would not seem to appreciably affect the natural male/female ratio. Genetic indications exert significant effects on the decision regarding sex selection procedures.
- 26 October 2005
- Published by Hindawi Limited in Andrologia
- Vol. 37 (5) , 155-159
Is semen quality affected by male body fat distribution?
The aim of this study was to examine the relationship of semen parameters, sexual function-related hormones and waist/hip ratio. Eighty-one selected patients presenting with infertility were examined. Weight, height, waist circumference and hip circumference were measured, and reproduction-related hormone levels were determined. Semen was analysed by conventional methods. Semen volume, sperm concentration, motility, total sperm count, total motile sperm cell number, rapid progressive motile sperm count and reproduction-related hormone levels [follicle-stimulating hormone, luteinizing hormone, prolactin, testosterone, 17β-oestradiol and sexual hormone-binding globulin (SHBG)]. Significant correlations were found: (i) weight, waist circumference and hip circumference versus testosterone level, SHBG level, and testosterone/17β-oestradiol ratio; (ii) hip circumference versus sperm concentration; (iii) waist circumference and hip circumference versus sperm count, total motile sperm cell number and rapid progressive motile sperm count; (iv) weight versus total sperm count and total motile sperm cell number; (v) waist circumference and hip circumference versus prolactin level (positively) and SHBG (negatively); (vi) waist circumference and waist/hip ratio versus semen volume. It can be concluded that the waist/hip ratio is correlated with the reproductive hormone levels. Although both the waist circumference and hip circumference correlated with the semen characteristics, the waist/hip ratio did not.
- 26 October 2005
- Published by Hindawi Limited in Andrologia
- Vol. 37 (5) , 155-159
Is semen quality affected by male body fat distribution?
The aim of this study was to examine the relationship of semen parameters, sexual function-related hormones and waist/hip ratio. Eighty-one selected patients presenting with infertility were examined. Weight, height, waist circumference and hip circumference were measured, and reproduction-related hormone levels were determined. Semen was analysed by conventional methods. Semen volume, sperm concentration, motility, total sperm count, total motile sperm cell number, rapid progressive motile sperm count and reproduction-related hormone levels [follicle-stimulating hormone, luteinizing hormone, prolactin, testosterone, 17β-oestradiol and sexual hormone-binding globulin (SHBG)]. Significant correlations were found: (i) weight, waist circumference and hip circumference versus testosterone level, SHBG level, and testosterone/17β-oestradiol ratio; (ii) hip circumference versus sperm concentration; (iii) waist circumference and hip circumference versus sperm count, total motile sperm cell number and rapid progressive motile sperm count; (iv) weight versus total sperm count and total motile sperm cell number; (v) waist circumference and hip circumference versus prolactin level (positively) and SHBG (negatively); (vi) waist circumference and waist/hip ratio versus semen volume. It can be concluded that the waist/hip ratio is correlated with the reproductive hormone levels. Although both the waist circumference and hip circumference correlated with the semen characteristics, the waist/hip ratio did not.
- 1 January 2005
- Published by Taylor & Francis in Archives of Andrology
- Vol. 51 (5) , 385-393
IS THERE A RELATIONSHIP BETWEEN CELL PHONE USE AND SEMEN QUALITY?
This study was conducted to determine a possible relationship between regular cell phone use and different human semen attributes. The history-taking of men in our university clinic was supplemented with questions concerning cell phone use habits, including possession, daily standby position and daily transmission times. Semen analyses were performed by conventional methods. Statistics were calculated with SPSS statistical software. A total of 371 were included in the study. The duration of possession and the daily transmission time correlated negatively with the proportion of rapid progressive motile sperm (r = -0.12 and r = -0.19, respectively), and positively with the proportion of slow progressive motile sperm (r = 0.12 and r = 0.28, respectively). The low and high transmitter groups also differed in the proportion of rapid progressive motile sperm (48.7% vs. 40.6%). The prolonged use of cell phones may have negative effects on the sperm motility characteristics.
- 1 January 2005
- Published by Taylor & Francis in Archives of Andrology
- Vol. 51 (5) , 385-393
IS THERE A RELATIONSHIP BETWEEN CELL PHONE USE AND SEMEN QUALITY?
This study was conducted to determine a possible relationship between regular cell phone use and different human semen attributes. The history-taking of men in our university clinic was supplemented with questions concerning cell phone use habits, including possession, daily standby position and daily transmission times. Semen analyses were performed by conventional methods. Statistics were calculated with SPSS statistical software. A total of 371 were included in the study. The duration of possession and the daily transmission time correlated negatively with the proportion of rapid progressive motile sperm (r = -0.12 and r = -0.19, respectively), and positively with the proportion of slow progressive motile sperm (r = 0.12 and r = 0.28, respectively). The low and high transmitter groups also differed in the proportion of rapid progressive motile sperm (48.7% vs. 40.6%). The prolonged use of cell phones may have negative effects on the sperm motility characteristics.
- 1 June 2003
- Vol. 16 (2) , 131-6
Magnesium-orotate supplementation for idiopathic infertile male patients: a randomized, placebo-controlled clinical pilot study.
A randomized, placebo-controlled clinical pilot study was performed in order to examine the effect of magnesium-orotate in male idiopathic infertility. Ten males were treated daily for 90 consecutive days with 3000 mg magnesium-orotate (Magnerot) tablets (Group M). As a control, ten other males were treated in the same way with placebo (Group P). Conventional microscopic sperm characteristics (sperm concentration, motility ratio, total number of motile sperm cells, normal morphology ratio), plus total and ionized magnesium levels in seminal plasma and blood serum were evaluated both prior to treatment and on day 90, at the conclusion of the study. No significant changes in sperm characteristics, blood ionized or total Mg, or ejaculate total Mg levels were detected. However, ejaculate ionized Mg levels increased in Group M from 0.18 +/- 0.05 to 0.30 +/- 0.05 (mmol/l; mean +/- SD, p < 0.05). Within the observation period of 3 months, one pregnancy occurred in the partner of a male from Group M. In conclusion, magnesium-orotate treatment at a dose of 3000 mg/day leads neither to a significant improvement of sperm variables nor does it increase the pregnancy rates of female partners of treated males as compared to those of controls. Thus, magnesium-orotate treatment was not shown to be effective therapy for idiopathic male infertility.
- 1 June 2003
- Vol. 16 (2) , 131-6
Magnesium-orotate supplementation for idiopathic infertile male patients: a randomized, placebo-controlled clinical pilot study.
A randomized, placebo-controlled clinical pilot study was performed in order to examine the effect of magnesium-orotate in male idiopathic infertility. Ten males were treated daily for 90 consecutive days with 3000 mg magnesium-orotate (Magnerot) tablets (Group M). As a control, ten other males were treated in the same way with placebo (Group P). Conventional microscopic sperm characteristics (sperm concentration, motility ratio, total number of motile sperm cells, normal morphology ratio), plus total and ionized magnesium levels in seminal plasma and blood serum were evaluated both prior to treatment and on day 90, at the conclusion of the study. No significant changes in sperm characteristics, blood ionized or total Mg, or ejaculate total Mg levels were detected. However, ejaculate ionized Mg levels increased in Group M from 0.18 +/- 0.05 to 0.30 +/- 0.05 (mmol/l; mean +/- SD, p < 0.05). Within the observation period of 3 months, one pregnancy occurred in the partner of a male from Group M. In conclusion, magnesium-orotate treatment at a dose of 3000 mg/day leads neither to a significant improvement of sperm variables nor does it increase the pregnancy rates of female partners of treated males as compared to those of controls. Thus, magnesium-orotate treatment was not shown to be effective therapy for idiopathic male infertility.