Akram Mohammadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akram Mohammadi has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Sakae Kinase
Japan Atomic Energy Agency
2 shared publications Kimiaki Saito
Medical Radioisotope Application Group, Japan Atomic Energy Agency (JAEA), 2–4 Shirakata, Shirane, Tokai-mura, Naka-gun, Ibaraki 319-1195 , Japan
1 shared publication
Latest Publications
- 14 December 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 150 (3) , 283-291
Evaluation of absorbed doses in voxel-based and simplified models for small animals
Internal dosimetry in non-human biota is desirable from the viewpoint of radiation protection of the environment. The International Commission on Radiological Protection (ICRP) proposed Reference Animals and Plants using simplified models, such as ellipsoids and spheres and calculated absorbed fractions (AFs) for whole bodies. In this study, photon and electron AFs in whole bodies of voxel-based rat and frog models have been calculated and compared with AFs in the reference models. It was found that the voxel-based and the reference frog (or rat) models can be consistent for the whole-body AFs within a discrepancy of 25 %, as the source was uniformly distributed in the whole body. The specific absorbed fractions (SAFs) and S values were also evaluated in whole bodies and all organs of the voxel-based frog and rat models as the source was distributed in the whole body or skeleton. The results demonstrated that the whole-body SAFs reflect SAFs of all individual organs as the source was uniformly distributed per mass within the whole body by about 30 % uncertainties with exceptions for body contour (up to −40 %) for both electrons and photons due to enhanced radiation leakages, and for the skeleton for photons only (up to +185 %) due to differences in the mass attenuation coefficients. For nuclides such as 90Y and 90Sr, which were concentrated in the skeleton, there were large differences between S values in the whole body and those in individual organs, however the whole-body S values for the reference models with the whole body as the source were remarkably similar to those for the voxel-based models with the skeleton as the source, within about 4 and 0.3 %, respectively. It can be stated that whole-body SAFs or S values in simplified models without internal organs are not sufficient for accurate internal dosimetry because they do not reflect SAFs or S values of all individual organs as the source was not distributed uniformly in whole body. Thus, voxel-based models would be good candidates for dosimetry in non-human biota if further accuracy in environmental dosimetry is desired.
- 14 December 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 150 (3) , 283-291
Evaluation of absorbed doses in voxel-based and simplified models for small animals
Internal dosimetry in non-human biota is desirable from the viewpoint of radiation protection of the environment. The International Commission on Radiological Protection (ICRP) proposed Reference Animals and Plants using simplified models, such as ellipsoids and spheres and calculated absorbed fractions (AFs) for whole bodies. In this study, photon and electron AFs in whole bodies of voxel-based rat and frog models have been calculated and compared with AFs in the reference models. It was found that the voxel-based and the reference frog (or rat) models can be consistent for the whole-body AFs within a discrepancy of 25 %, as the source was uniformly distributed in the whole body. The specific absorbed fractions (SAFs) and S values were also evaluated in whole bodies and all organs of the voxel-based frog and rat models as the source was distributed in the whole body or skeleton. The results demonstrated that the whole-body SAFs reflect SAFs of all individual organs as the source was uniformly distributed per mass within the whole body by about 30 % uncertainties with exceptions for body contour (up to −40 %) for both electrons and photons due to enhanced radiation leakages, and for the skeleton for photons only (up to +185 %) due to differences in the mass attenuation coefficients. For nuclides such as 90Y and 90Sr, which were concentrated in the skeleton, there were large differences between S values in the whole body and those in individual organs, however the whole-body S values for the reference models with the whole body as the source were remarkably similar to those for the voxel-based models with the skeleton as the source, within about 4 and 0.3 %, respectively. It can be stated that whole-body SAFs or S values in simplified models without internal organs are not sufficient for accurate internal dosimetry because they do not reflect SAFs or S values of all individual organs as the source was not distributed uniformly in whole body. Thus, voxel-based models would be good candidates for dosimetry in non-human biota if further accuracy in environmental dosimetry is desired.
- Open Access
- 30 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 258-263
Influence of voxel size on specific absorbed fractions and S-values in a mouse voxel phantom
Photon and electron specific absorbed fractions (SAFs) and S-values have been evaluated using mouse voxel phantoms. In voxel phantoms, it is important to choose the voxel size carefully since it affects the accuracy of results. In this study, two mouse voxel phantoms were constructed, with cubic voxels, one with 0.1-mm sides and the other with 0.4-mm sides. The sources were considered to be distributed uniformly in the main organs and the radiation transport was simulated using the Monte Carlo code EGS4. It was found that the effect of voxel size on SAFs for self-irradiation was not high (S-values for some beta emitters such as 131I, 153Sm, 188Re and 90Y.
- 30 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 258-263
Open AccessInfluence of voxel size on specific absorbed fractions and S-values in a mouse voxel phantom
Photon and electron specific absorbed fractions (SAFs) and S-values have been evaluated using mouse voxel phantoms. In voxel phantoms, it is important to choose the voxel size carefully since it affects the accuracy of results. In this study, two mouse voxel phantoms were constructed, with cubic voxels, one with 0.1-mm sides and the other with 0.4-mm sides. The sources were considered to be distributed uniformly in the main organs and the radiation transport was simulated using the Monte Carlo code EGS4. It was found that the effect of voxel size on SAFs for self-irradiation was not high (S-values for some beta emitters such as 131I, 153Sm, 188Re and 90Y.