Tetsuya Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tetsuya Watanabe has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Hirohisa Hara
National Astronomical Observatory of Japan
7 shared publications - Daiji Kato
National Institute for Fusion Science
5 shared publications - Izumi Murakami
National Institute for Fusion Science, National Institutes of Natural Sciences
4 shared publications - Hiroyuki A. Sakaue
National Institute for Fusion Science, National Institutes of Natural Sciences, Toki, Gifu 509-5292, Japan
3 shared publications - Nobuyuki Nakamura
University of Electro Communications
3 shared publications - Peter R. Young
Northumbria University
3 shared publications
Latest Publications
- 28 March 2018
- Published by Springer Nature
- p. 53-62
Solar Extreme Ultraviolet Spectroscopy: zur NachEISzeit
- 28 March 2018
- Published by Springer Nature
- p. 53-62
Solar Extreme Ultraviolet Spectroscopy: zur NachEISzeit
- 1 October 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 408, 191-193
Resonant excitation of Fe 14+ observed with a compact electron beam ion trap
- 1 October 2017
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 408, 191-193
Resonant excitation of Fe 14+ observed with a compact electron beam ion trap
- Open Access
- 7 June 2017
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 842 (1) , 12
Neon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode/EUV Imaging Spectrometer (EIS)
Line intensities emerging from the Ne-sequence iron ion (Fe xvii) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe xvii λ 204.6/λ 254.8 are derived in the laboratory by unblending the contributions of the Fe xiii and xii line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.
- 7 June 2017
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 842 (1) , 12
Open AccessNeon-like Iron Ion Lines Measured in NIFS/Large Helical Device (LHD) and Hinode/EUV Imaging Spectrometer (EIS)
Line intensities emerging from the Ne-sequence iron ion (Fe xvii) are measured in the laboratory, by the Large Helical Device at the National Institute for Fusion Science, and in the solar corona by the EUV Imaging Spectrometer (EIS) on board the Hinode mission. The intensity ratios of Fe xvii λ 204.6/λ 254.8 are derived in the laboratory by unblending the contributions of the Fe xiii and xii line intensities. They are consistent with theoretical predictions and solar observations, the latter of which endorses the in-flight radiometric calibrations of the EIS instrument. The still remaining temperature-dependent behavior of the line ratio suggests the contamination of lower-temperature iron lines that are blended with the λ 204.6 line.
- 1 June 2015
- Vol. 61 (1) , 43-52
Pentraxin-3 as a Biomarker for Febrile Neutropenia in Patients with Lung Cancer.
Pentraxin-3 (PTX3) is a newly discovered biomarker for various inflammatory conditions. We measured plasma PTX3 levels in patients with febrile neutropenic lung cancer and examined the utility of PTX3 levels as a biomarker for febrile neutropenia. Fourteen patients with febrile neutropenic lung cancer were enrolled in the study. In addition, 10 untreated lung cancer patients and 12 healthy adults were enrolled as a disease control group and a healthy control group, respectively. On the day of onset of febrile neutropenia (day 1) and days 3 and 7, PTX3 and C-reactive protein (CRP) levels were measured. In the control groups, PTX3 and CRP levels were measured once. On day 1, plasma CRP levels in febrile neutropenia during chemotherapy or chemoradiotherapy for lung cancer (FN/LC) patients (8.11 ± 6.42 mg/dL) were significantly higher than those in healthy controls (HC) and chemotherapy/chemoradiotherapy-naïve lung cancer (CN/LC) patients (p < 0.05). However, CRP levels of the CN/LC group (0.33 ± 0.02 mg/dL) were also significantly higher than those of the HC group (0.07 ± 0.09 mg/dL) (p < 0.05). In contrast, plasma PTX3 levels of the FN/LC group (6.14 ± 5.28 ng/mL) were significantly higher than those of the HC and CN/LC groups on day 1 (p < 0.05), but PTX3 levels of the CN/LC group (1.60 ± 0.64 ng/mL) were not significantly higher than those of the HC group (1.05 ± 0.25 ng/mL). In the FN/LC group, PTX3 levels peaked immediately on day 1. PTX3 may be a useful biomarker for diagnosis of FN in patients with LC.
- 1 June 2015
- Vol. 61 (1) , 43-52
Pentraxin-3 as a Biomarker for Febrile Neutropenia in Patients with Lung Cancer.
Pentraxin-3 (PTX3) is a newly discovered biomarker for various inflammatory conditions. We measured plasma PTX3 levels in patients with febrile neutropenic lung cancer and examined the utility of PTX3 levels as a biomarker for febrile neutropenia. Fourteen patients with febrile neutropenic lung cancer were enrolled in the study. In addition, 10 untreated lung cancer patients and 12 healthy adults were enrolled as a disease control group and a healthy control group, respectively. On the day of onset of febrile neutropenia (day 1) and days 3 and 7, PTX3 and C-reactive protein (CRP) levels were measured. In the control groups, PTX3 and CRP levels were measured once. On day 1, plasma CRP levels in febrile neutropenia during chemotherapy or chemoradiotherapy for lung cancer (FN/LC) patients (8.11 ± 6.42 mg/dL) were significantly higher than those in healthy controls (HC) and chemotherapy/chemoradiotherapy-naïve lung cancer (CN/LC) patients (p < 0.05). However, CRP levels of the CN/LC group (0.33 ± 0.02 mg/dL) were also significantly higher than those of the HC group (0.07 ± 0.09 mg/dL) (p < 0.05). In contrast, plasma PTX3 levels of the FN/LC group (6.14 ± 5.28 ng/mL) were significantly higher than those of the HC and CN/LC groups on day 1 (p < 0.05), but PTX3 levels of the CN/LC group (1.60 ± 0.64 ng/mL) were not significantly higher than those of the HC group (1.05 ± 0.25 ng/mL). In the FN/LC group, PTX3 levels peaked immediately on day 1. PTX3 may be a useful biomarker for diagnosis of FN in patients with LC.
- 1 October 2014
- Published by Elsevier in Annals of Oncology
- Vol. 25, v68
Short Hydration Versus Continuous Hydration in Chemotherapy Containing Intermediate- to High-Dose Cisplatin
Background and aims: The efficacy of the short hydration regimen was reported in chemotherapy containing intermediate- to high-dose cisplatin, and the use of outpatient chemotherapy containing cisplatin with short hydration has been widespread in recent years. We have provided outpatient chemotherapy containing cisplatin with the short hydration regimen since July 2012. The aim of this study was to evaluate the safety and efficacy of the short hydration regimen. Methods: We compared patients with gastric cancer, lung cancer, and urothelial cancer who received outpatient chemotherapy containing cisplatin (≥ 60 mg/m2/cycle) with the short hydration regimen since July 2012 (n = 13) with those who received hospital chemotherapy with continuous hydration between April 2011 and June 2012 (n = 17) in our hospital. To assess the incidence of cisplatin nephrotoxicity and the effect of the treatment, serum creatinine and creatinine clearance levels were monitored and relative dose intensity (RDI) was calculated. Results: There was no difference between the 2 groups with respect to the background factors. Grade 2 or higher acute kidney injury occurred in 2 patients in the continuous hydration group and in no patient in the short hydration group; 1 patient discontinued treatment on account of nephrotoxicity. There was no difference between the 2 groups in the average value of maximum creatinine increment (0.14 mg/dl vs. 0.32 mg/dl; p = 0.43) and maximum clearance decrement (10.9 ml/min vs. 18.3 ml/min; p = 0.28). RDI in the short hydration group was higher than that in the continuous hydration group (89.5% vs. 80.3%; p < 0.01). Conclusions: The short hydration regimen in outpatient chemotherapy containing intermediate- to high-dose cisplatin is as safe as the continuous hydration regimen, and increases the efficacy with the convenience of chemotherapy scheduling.
- 1 October 2014
- Published by Elsevier in Annals of Oncology
- Vol. 25, v68
Short Hydration Versus Continuous Hydration in Chemotherapy Containing Intermediate- to High-Dose Cisplatin
Background and aims: The efficacy of the short hydration regimen was reported in chemotherapy containing intermediate- to high-dose cisplatin, and the use of outpatient chemotherapy containing cisplatin with short hydration has been widespread in recent years. We have provided outpatient chemotherapy containing cisplatin with the short hydration regimen since July 2012. The aim of this study was to evaluate the safety and efficacy of the short hydration regimen. Methods: We compared patients with gastric cancer, lung cancer, and urothelial cancer who received outpatient chemotherapy containing cisplatin (≥ 60 mg/m2/cycle) with the short hydration regimen since July 2012 (n = 13) with those who received hospital chemotherapy with continuous hydration between April 2011 and June 2012 (n = 17) in our hospital. To assess the incidence of cisplatin nephrotoxicity and the effect of the treatment, serum creatinine and creatinine clearance levels were monitored and relative dose intensity (RDI) was calculated. Results: There was no difference between the 2 groups with respect to the background factors. Grade 2 or higher acute kidney injury occurred in 2 patients in the continuous hydration group and in no patient in the short hydration group; 1 patient discontinued treatment on account of nephrotoxicity. There was no difference between the 2 groups in the average value of maximum creatinine increment (0.14 mg/dl vs. 0.32 mg/dl; p = 0.43) and maximum clearance decrement (10.9 ml/min vs. 18.3 ml/min; p = 0.28). RDI in the short hydration group was higher than that in the continuous hydration group (89.5% vs. 80.3%; p < 0.01). Conclusions: The short hydration regimen in outpatient chemotherapy containing intermediate- to high-dose cisplatin is as safe as the continuous hydration regimen, and increases the efficacy with the convenience of chemotherapy scheduling.
- 1 July 2014
- Vol. 41 (7) , 889-91
[A patient with paclitaxel hypersensitivity treated with nab-paclitaxel].
A 63-year-old man with multiple liver metastases from gastric cancer was treated with S-1 plus cisplatin; however, the number of multiple liver metastases increased. The patient received paclitaxel(PTX)treatment, but a hypersensitivity reaction occurred after administering the second dose; therefore, he received docetaxel treatment. A hypersensitivity reaction occurred after administering the first dose of docetaxel; therefore, he received irinotecan treatment. However, irinotecan administration was stopped because of severe diarrhea and weight reduction. Subsequently, at the patient's request, nab-PTX treatment was initiated by administering a premedication regimen of dexamethasone(8mg)and chlorpheniramine(10mg); no hypersensitivity reactions were reported thereafter. Nab-PTX is a contraindication; however, it might be possible to use nab-PTX for treating patients with PTX hypersensitivity.
- 1 July 2014
- Vol. 41 (7) , 889-91
[A patient with paclitaxel hypersensitivity treated with nab-paclitaxel].
A 63-year-old man with multiple liver metastases from gastric cancer was treated with S-1 plus cisplatin; however, the number of multiple liver metastases increased. The patient received paclitaxel(PTX)treatment, but a hypersensitivity reaction occurred after administering the second dose; therefore, he received docetaxel treatment. A hypersensitivity reaction occurred after administering the first dose of docetaxel; therefore, he received irinotecan treatment. However, irinotecan administration was stopped because of severe diarrhea and weight reduction. Subsequently, at the patient's request, nab-PTX treatment was initiated by administering a premedication regimen of dexamethasone(8mg)and chlorpheniramine(10mg); no hypersensitivity reactions were reported thereafter. Nab-PTX is a contraindication; however, it might be possible to use nab-PTX for treating patients with PTX hypersensitivity.
- 11 July 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1545 (1) , 62
EBIT spectroscopy of highly charged heavy ions relevant to hot plasmas
We present spectra of highly charged iron, gadolinium, and tungsten ions obtained with electron beam ion traps. Spectroscopic studies of these ions are important to diagnose and control hot plasmas in several areas. For iron ions, the electron density dependence of the line intensity ratio in extreme ultraviolet spectra is investigated for testing the model calculation used in solar corona diagnostics. Soft x-ray spectra of gadolinium are studied to obtain atomic data required in light source development for future lithography. Tungsten is considered to be the main impurity in the ITER plasma, and thus visible and soft x-ray spectra of tungsten have been observed to explore the emission lines useful for the spectroscopic diagnostics of the ITER plasma.
- 11 July 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1545 (1) , 62
EBIT spectroscopy of highly charged heavy ions relevant to hot plasmas
We present spectra of highly charged iron, gadolinium, and tungsten ions obtained with electron beam ion traps. Spectroscopic studies of these ions are important to diagnose and control hot plasmas in several areas. For iron ions, the electron density dependence of the line intensity ratio in extreme ultraviolet spectra is investigated for testing the model calculation used in solar corona diagnostics. Soft x-ray spectra of gadolinium are studied to obtain atomic data required in light source development for future lithography. Tungsten is considered to be the main impurity in the ITER plasma, and thus visible and soft x-ray spectra of tungsten have been observed to explore the emission lines useful for the spectroscopic diagnostics of the ITER plasma.
- 9 August 2012
- Published by Springer Nature in Solar Physics
- Vol. 281 (1) , 87-99
Production of High-Temperature Plasmas During the Early Phases of a C9.7 Flare. II. Bi-directional Flows Suggestive of Reconnection in a Pre-flare Brightening Region
- 9 August 2012
- Published by Springer Nature in Solar Physics
- Vol. 281 (1) , 87-99
Production of High-Temperature Plasmas During the Early Phases of a C9.7 Flare. II. Bi-directional Flows Suggestive of Reconnection in a Pre-flare Brightening Region
- 19 May 2011
- Published by AIP Publishing
- Vol. 1344 (1) , 96
Database and Related Activities in Japan
We have constructed and made available atomic and molecular (AM) numerical databases on collision processes such as electron‐impact excitation and ionization, recombination and charge transfer of atoms and molecules relevant for plasma physics, fusion research, astrophysics, applied‐science plasma, and other related areas. The retrievable data is freely accessible via the internet. We also work on atomic data evaluation and constructing collisional‐radiative models for spectroscopic plasma diagnostics. Recently we have worked on Fe ions and W ions theoretically and experimentally. The atomic data and collisional‐radiative models for these ions are examined and applied to laboratory plasmas. A visible M1 transition of ion is identified at 389.41 nm by EBIT experiments and theoretical calculations. We have small non‐retrievable databases in addition to our main database. Recently we evaluated photo‐absorption cross sections for 9 atoms and 23 molecules and we present them as a new database. We established a new association “Forum of Atomic and Molecular Data and Their Applications” to exchange information among AM data producers, data providers and data users in Japan and we hope this will help to encourage AM data activities in Japan.- 19 May 2011
- Published by AIP Publishing
- Vol. 1344 (1) , 96
Database and Related Activities in Japan
We have constructed and made available atomic and molecular (AM) numerical databases on collision processes such as electron‐impact excitation and ionization, recombination and charge transfer of atoms and molecules relevant for plasma physics, fusion research, astrophysics, applied‐science plasma, and other related areas. The retrievable data is freely accessible via the internet. We also work on atomic data evaluation and constructing collisional‐radiative models for spectroscopic plasma diagnostics. Recently we have worked on Fe ions and W ions theoretically and experimentally. The atomic data and collisional‐radiative models for these ions are examined and applied to laboratory plasmas. A visible M1 transition of ion is identified at 389.41 nm by EBIT experiments and theoretical calculations. We have small non‐retrievable databases in addition to our main database. Recently we evaluated photo‐absorption cross sections for 9 atoms and 23 molecules and we present them as a new database. We established a new association “Forum of Atomic and Molecular Data and Their Applications” to exchange information among AM data producers, data providers and data users in Japan and we hope this will help to encourage AM data activities in Japan.- 1 April 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 163 (1) , 012002
Spectroscopy of highly charged ions in Solar and astrophysical plasmas
Spectroscopic observation of EUV emission lines in the transition-region and corona provide unique information on physical conditions in these outer atmospheres of the Sun. The EUV Imaging Spectrometer (the EIS) on board the Hinode mission is capable of observing, for the first time in Solar EUV observations, spectra and monochromatic images of possibly non-ionization-equilibrium plasmas in the solar transition-region and corona at two-wavelength bands of 170 - 210Å and 250 - 290Å, with typical time-resolutions of 1 -10 seconds. Dynamic plasma acceleration and heating are found to take place in the solar atmospheres, and they are confined in tiny structures. A time-dependent collisional-radiative model for the iron plasmas is developed to diagnose temperatures and densities in the outer atmospheres of the Sun; no systematic models yet exist for iron ions at the ionization stages of L- and M-shells, which are very important for coronal plasma diagnostics. Adopting the best available theoretical calculations of atomic parameters of these iron ions, as well as generating the experimental data by a compact electron beam ion trap (EBIT), is essential to one of the aims of our research that the mechanism of coronal heating is explored via accurate diagnostics information obtained by the EIS instrument.
- 1 April 2009
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 163 (1) , 012002
Spectroscopy of highly charged ions in Solar and astrophysical plasmas
Spectroscopic observation of EUV emission lines in the transition-region and corona provide unique information on physical conditions in these outer atmospheres of the Sun. The EUV Imaging Spectrometer (the EIS) on board the Hinode mission is capable of observing, for the first time in Solar EUV observations, spectra and monochromatic images of possibly non-ionization-equilibrium plasmas in the solar transition-region and corona at two-wavelength bands of 170 - 210Å and 250 - 290Å, with typical time-resolutions of 1 -10 seconds. Dynamic plasma acceleration and heating are found to take place in the solar atmospheres, and they are confined in tiny structures. A time-dependent collisional-radiative model for the iron plasmas is developed to diagnose temperatures and densities in the outer atmospheres of the Sun; no systematic models yet exist for iron ions at the ionization stages of L- and M-shells, which are very important for coronal plasma diagnostics. Adopting the best available theoretical calculations of atomic parameters of these iron ions, as well as generating the experimental data by a compact electron beam ion trap (EBIT), is essential to one of the aims of our research that the mechanism of coronal heating is explored via accurate diagnostics information obtained by the EIS instrument.