Søren Torp-Pedersen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Søren Torp-Pedersen has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Henning Bliddal
The Parker Institute, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark
5 shared publications - Robin Christensen
The Parker Institute: MSU, Copenhagen University Hospital, Frederiksberg, Copenhagen, Denmark
4 shared publications Bente Danneskiold-Samsøe
3 shared publications- Jens Erik Wilhjelm
Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark
3 shared publications E. M. Bartels
The Parker Institute, Frederiksberg Hospital
2 shared publicationsKirstine Amris
The Parker Institute, Frederiksberg Hospital, Copenhagen, Denmark
2 shared publications
Latest Publications
- 21 May 2013
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 35 (02) , 137-141
Validity and Reliability of 3D US for the Detection of Erosions in Patients with Rheumatoid Arthritis Using MRI as the Gold Standard
Purpose: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. Materials and Methods: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were estimated according to a semi-quantitative score (SQS) (0 – 3) and a quantitative score (QS) (mm2). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman’s rho (rs). The sensitivity and specificity were also calculated. Results: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS. The ICC for the intra-observer reliability in the QS was 0.75 and 0.48 for the metacarpal bone and phalangeal bone, respectively, and 0.83 and 0.60, respectively, in the SQS. The correlation with MRI for the metacarpal bone was significant, with values of 0.73 (p = 0.0001) (SQ) and 0.74 (p = 0.0001) (SQS). For the phalangeal bone, bad correlation was found: 0.28 (p = 0.145) (SQ) and 0.26 (p = 0.57) (SQS). The sensitivity and specificity for the metacarpal bone were 86 % and 85 % respectively. For the phalangeal bone they were 60 % and 97 %, respectively. Conclusion: Good inter- and intra-observer reliability and correlation with MRI were seen in the assessment of erosions with 3D US in the metacarpal bone, while the results were low and insignificant for the phalangeal bone, indicating that 3D US still has room for improvement. Ziel: Bestimmung der Verlässlichkeit und Aussagekraft der 3-D-US-Erosionsskala bei RA unter Verwendung von MRI als Goldstandard. Material und Methoden: RA-Patienten wurden mittels 3-D-US und 3T-MRT über dem 2. und 3. Metakarpophalangealgelenk untersucht. Die 3-D-Blöcke wurden von 2 Untersuchern bewertet. Die Erosionen wurden nach dem semiquantitativen Score (SQS) (0 – 3) und dem quantitativen Score (QS) (mm2) bewertet. Die MRT wurde mittels RAMRIS-Score beurteilt. Für die Bewertung der Verlässlichkeit wurden Intraklasse-Korrelationskoeffizienten (ICC) benutzt. Die Aussagekraft wurde mittels Spearmans Rho (rs) bestimmt. Die Sensitivität und Spezifität wurde ebenfalls bestimmt. Ergebnisse: Es wurden 28 Patienten mit RA eingeschlossen. Die ICCs der Interobserver-Reliabitität beim QS betrugen für den metakarpalen Knochen 0,41 und für den phalangealen Knochen 0,13. Beim SQS betrugen diese 0,86 für den metakarpalen und 0,16 für den phalangealen Knochen. Die ICCs der Intraobserver-Reliabitität beim QS betrugen für den metakarpalen Knochen 0,75 und für den phalangealen Knochen 0,48. Beim SQS betrugen diese 0,83 für den metakarpalen und 0,60 für den phalangealen Knochen. Die Übereinstimmung mit der MRT für den metakarpalen Knochen war signifikant mit Werten von 0,73 (p = 0,0001) für den SQ und 0,74 (p = 0,0001) für den SQS. Beim phalangealen Knochen konnte mit 0,28 (p = 0,145) für den SQ und 0,26 (p = 0,57) für den SQS keine Übereinstimmung gefunden werden. Beim metakarpalen Knochen betrug die Sensitivität 86 % und die Spezifität 85 %. Beim phalangealen Knochen betrug die Sensitivität 60 % und die Spezifität 97 %. Schlussfolgerung: Bei der Bewertung der Erosionen des metakarpalen Knochens mittels 3-D-US wurden eine gute Inter- und Intraobserver-Reliabilität sowie eine gute Übereinstimmung mit der MRT beobachtet. Gleichzeitig waren die Ergebnisse für den phalangealen Knochen schlecht und nicht signifikant, was darauf hinweist, dass der 3-D-US noch verbesserungsfähig ist.
- 21 May 2013
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 35 (02) , 137-141
Validity and Reliability of 3D US for the Detection of Erosions in Patients with Rheumatoid Arthritis Using MRI as the Gold Standard
Purpose: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. Materials and Methods: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were estimated according to a semi-quantitative score (SQS) (0 – 3) and a quantitative score (QS) (mm2). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman’s rho (rs). The sensitivity and specificity were also calculated. Results: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS. The ICC for the intra-observer reliability in the QS was 0.75 and 0.48 for the metacarpal bone and phalangeal bone, respectively, and 0.83 and 0.60, respectively, in the SQS. The correlation with MRI for the metacarpal bone was significant, with values of 0.73 (p = 0.0001) (SQ) and 0.74 (p = 0.0001) (SQS). For the phalangeal bone, bad correlation was found: 0.28 (p = 0.145) (SQ) and 0.26 (p = 0.57) (SQS). The sensitivity and specificity for the metacarpal bone were 86 % and 85 % respectively. For the phalangeal bone they were 60 % and 97 %, respectively. Conclusion: Good inter- and intra-observer reliability and correlation with MRI were seen in the assessment of erosions with 3D US in the metacarpal bone, while the results were low and insignificant for the phalangeal bone, indicating that 3D US still has room for improvement. Ziel: Bestimmung der Verlässlichkeit und Aussagekraft der 3-D-US-Erosionsskala bei RA unter Verwendung von MRI als Goldstandard. Material und Methoden: RA-Patienten wurden mittels 3-D-US und 3T-MRT über dem 2. und 3. Metakarpophalangealgelenk untersucht. Die 3-D-Blöcke wurden von 2 Untersuchern bewertet. Die Erosionen wurden nach dem semiquantitativen Score (SQS) (0 – 3) und dem quantitativen Score (QS) (mm2) bewertet. Die MRT wurde mittels RAMRIS-Score beurteilt. Für die Bewertung der Verlässlichkeit wurden Intraklasse-Korrelationskoeffizienten (ICC) benutzt. Die Aussagekraft wurde mittels Spearmans Rho (rs) bestimmt. Die Sensitivität und Spezifität wurde ebenfalls bestimmt. Ergebnisse: Es wurden 28 Patienten mit RA eingeschlossen. Die ICCs der Interobserver-Reliabitität beim QS betrugen für den metakarpalen Knochen 0,41 und für den phalangealen Knochen 0,13. Beim SQS betrugen diese 0,86 für den metakarpalen und 0,16 für den phalangealen Knochen. Die ICCs der Intraobserver-Reliabitität beim QS betrugen für den metakarpalen Knochen 0,75 und für den phalangealen Knochen 0,48. Beim SQS betrugen diese 0,83 für den metakarpalen und 0,60 für den phalangealen Knochen. Die Übereinstimmung mit der MRT für den metakarpalen Knochen war signifikant mit Werten von 0,73 (p = 0,0001) für den SQ und 0,74 (p = 0,0001) für den SQS. Beim phalangealen Knochen konnte mit 0,28 (p = 0,145) für den SQ und 0,26 (p = 0,57) für den SQS keine Übereinstimmung gefunden werden. Beim metakarpalen Knochen betrug die Sensitivität 86 % und die Spezifität 85 %. Beim phalangealen Knochen betrug die Sensitivität 60 % und die Spezifität 97 %. Schlussfolgerung: Bei der Bewertung der Erosionen des metakarpalen Knochens mittels 3-D-US wurden eine gute Inter- und Intraobserver-Reliabilität sowie eine gute Übereinstimmung mit der MRT beobachtet. Gleichzeitig waren die Ergebnisse für den phalangealen Knochen schlecht und nicht signifikant, was darauf hinweist, dass der 3-D-US noch verbesserungsfähig ist.
- Open Access
- 12 March 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 1-9
Feasibility of a standardized ultrasound examination in patients with rheumatoid arthritis: a quality improvement among rheumatologists cohort
Quality improvement is important to facilitate valid patient outcomes. Standardized examination procedures may improve the validity of US. The aim of this study was to investigate the learning progress for rheumatologists during training of US examination of the hand in patients with rheumatoid arthritis (RA). Rheumatologists with varying degrees of experience in US were instructed by skilled tutors. The program consisted of two days with hands-on training followed by personal US examinations performed in their individual clinics. Examinations were sent to the tutors for quality control. The US examinations were evaluated according to a scoring sheet containing 144 items. An acceptable examination was defined as > 80% correct scores. Thirteen rheumatologists participated in the study. They included a total of 104 patients with RA. Only few of the initial examinations were scored below 80%, and as experience increased, the scores improved (p = 0.0004). A few participants displayed decreasing scores. The mean time spent performing the standardized examination procedure decreased from 34 min to less than 10 minutes (p = 0.0001). With systematic hands-on training, a rheumatologist can achieve a high level of proficiency in the conduction of US examinations of the joints of the hand in patients with RA. With experience, examination time decreases, while the level of correctness is maintained. The results indicate that US may be applied as a valid measurement tool suitable for clinical practice and in both single- and multi-centre trials.
- 12 March 2012
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 13 (1) , 1-9
Open AccessFeasibility of a standardized ultrasound examination in patients with rheumatoid arthritis: a quality improvement among rheumatologists cohort
Quality improvement is important to facilitate valid patient outcomes. Standardized examination procedures may improve the validity of US. The aim of this study was to investigate the learning progress for rheumatologists during training of US examination of the hand in patients with rheumatoid arthritis (RA). Rheumatologists with varying degrees of experience in US were instructed by skilled tutors. The program consisted of two days with hands-on training followed by personal US examinations performed in their individual clinics. Examinations were sent to the tutors for quality control. The US examinations were evaluated according to a scoring sheet containing 144 items. An acceptable examination was defined as > 80% correct scores. Thirteen rheumatologists participated in the study. They included a total of 104 patients with RA. Only few of the initial examinations were scored below 80%, and as experience increased, the scores improved (p = 0.0004). A few participants displayed decreasing scores. The mean time spent performing the standardized examination procedure decreased from 34 min to less than 10 minutes (p = 0.0001). With systematic hands-on training, a rheumatologist can achieve a high level of proficiency in the conduction of US examinations of the joints of the hand in patients with RA. With experience, examination time decreases, while the level of correctness is maintained. The results indicate that US may be applied as a valid measurement tool suitable for clinical practice and in both single- and multi-centre trials.
- 30 July 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (01) , E1
Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation
Erratum: Torp-Pedersen S, Bartels EM, Wilhjelm J, Bliddal H. Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation. Ultraschall in Med 2010: DOI 10.1055/s-0029-1245386 In the fourth paragraph of the introduction the wording needed to be corrected. The correct sentence is: “In addition to the above, it is well known in other areas of medical US, where accurate measurements are important, that the transducer-near end of a white band is reliable while the transducer-far end cannot be trusted.” The publisher apologizes for this mistake.
- 30 July 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (01) , E1
Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation
Erratum: Torp-Pedersen S, Bartels EM, Wilhjelm J, Bliddal H. Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation. Ultraschall in Med 2010: DOI 10.1055/s-0029-1245386 In the fourth paragraph of the introduction the wording needed to be corrected. The correct sentence is: “In addition to the above, it is well known in other areas of medical US, where accurate measurements are important, that the transducer-near end of a white band is reliable while the transducer-far end cannot be trusted.” The publisher apologizes for this mistake.
- 28 May 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (01) , 54-61
Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation
Hintergrund: Theoretisch sollte der Ultraschall dank seiner hohen räumlichen Auflösung sehr geeignet sein, um Veränderungen der artikulären Knorpeldicke bei Osteoarthritis im Krankheitsverlauf darzustellen. Voraussetzung hierfür ist allerdings, dass die Knorpelgrenzen gut identifizierbar sind und dass der Knorpel in orthogonaler Schnittführung untersucht wird. Wenn US-gestützte Messungen mit anderen Untersuchungstechniken verglichen werden, sollte der höheren Ultraschallgeschwindigkeit im Knorpel Rechnung getragen werden. Ziel: Geprüft werden sollte, ob die Untersucher den artikulären Knorpel korrekt identifizierten, ob in orthogonaler Schnittführung untersucht wurde und ob eine Korrektur für die Schallgeschwindigkeit durchgeführt wurde. Material und Methoden: Zeitlich auf die vergangenen 10 Jahre begrenzte Literaturrecherche zum Thema „US zur Messung der Knorpeldicke”. Ergebnisse: 15 Studien zur Messung der Knorpeldicke wurden identifiziert, diese wiederum verwiesen auf 8 weitere Studien. 11 der 15 Studien identifizierten die oberflächliche Knorpelgrenze nicht korrekt, in 6 Arbeiten wurde mittels schräger Schnittführung untersucht. In 2 der 15 Studien wurde eine Korrektur für die Schallgeschwindigkeit durchgeführt. In den weiteren 8 Studien wurde in einer die Messung der oberflächlichen Knorpelgrenze vermutlich adäquat durchgeführt, bei 4 Studien wurde in schräger Schnittführung untersucht, und in keiner Arbeit wurde eine Korrektur für die Schallgeschwindigkeit durchgeführt. Schlussfolgerung: Wir konnten zeigen, dass in der Mehrzahl der Studien, die in den letzten 10 Jahren zum Thema US-gestützte Knorpeldicke-Messung publiziert wurden, die Knorpeldicke systematisch unterschätzt wurde, da die zum Knorpel gehörende Grenzschicht nicht mitgemessen wurde. Da der Knorpel relativ dünn ist, ist dieser Fehler beträchtlich. Einige Autoren überschätzten die Knorpeldicke, indem sie mit schrägen Schnittführungen arbeiteten. Bei vielen Untersuchern kommt es durch fehlende Korrektur für die hohe Schallgeschwindigkeit im Knorpel zu einer systematischen Unterschätzung der Knorpeldicke. Background: Theoretically, the high spatial resolution of US makes it well suited to monitor the decrease in articular cartilage thickness in osteoarthritis. A requirement is, however, that the borders of the cartilage are correctly identified and that the cartilage is measured under orthogonal insonation. If US measurements are compared to measurements with other techniques, they should be corrected for the higher sound speed in cartilage. Purpose: To study whether investigators correctly identify the articular cartilage, whether they insonate orthogonally, and whether they correct for sound speed. Materials and Methods: A literature search limited to the last 10 years of studies applying US to measure cartilage thickness. Results: 15 studies were identified and they referred to another 8 studies describing methods of thickness measurement. 11 of the 15 studies identified the superficial cartilage border incorrectly, and 6 applied oblique insonation. 2 of the 15 studies corrected for sound speed. Of the further 8 studies, one might correctly identify the superficial cartilage border, 4 applied oblique insonation, and none corrected for sound speed. Conclusion: We found that the majority of studies over the last 10 years, evaluating articular cartilage thickness with US, underestimated the cartilage thickness by not including the leading interface as part of the cartilage. Since the cartilage is relatively thin, this error is substantial. Some investigators also overestimated cartilage thickness by using oblique insonation of the cartilage. By not correcting for the high sound speed in cartilage, most investigators underestimated the cartilage thickness.
- 28 May 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (01) , 54-61
Articular Cartilage Thickness Measured with US is Not as Easy as It Appears: A Systematic Review of Measurement Techniques and Image Interpretation
Hintergrund: Theoretisch sollte der Ultraschall dank seiner hohen räumlichen Auflösung sehr geeignet sein, um Veränderungen der artikulären Knorpeldicke bei Osteoarthritis im Krankheitsverlauf darzustellen. Voraussetzung hierfür ist allerdings, dass die Knorpelgrenzen gut identifizierbar sind und dass der Knorpel in orthogonaler Schnittführung untersucht wird. Wenn US-gestützte Messungen mit anderen Untersuchungstechniken verglichen werden, sollte der höheren Ultraschallgeschwindigkeit im Knorpel Rechnung getragen werden. Ziel: Geprüft werden sollte, ob die Untersucher den artikulären Knorpel korrekt identifizierten, ob in orthogonaler Schnittführung untersucht wurde und ob eine Korrektur für die Schallgeschwindigkeit durchgeführt wurde. Material und Methoden: Zeitlich auf die vergangenen 10 Jahre begrenzte Literaturrecherche zum Thema „US zur Messung der Knorpeldicke”. Ergebnisse: 15 Studien zur Messung der Knorpeldicke wurden identifiziert, diese wiederum verwiesen auf 8 weitere Studien. 11 der 15 Studien identifizierten die oberflächliche Knorpelgrenze nicht korrekt, in 6 Arbeiten wurde mittels schräger Schnittführung untersucht. In 2 der 15 Studien wurde eine Korrektur für die Schallgeschwindigkeit durchgeführt. In den weiteren 8 Studien wurde in einer die Messung der oberflächlichen Knorpelgrenze vermutlich adäquat durchgeführt, bei 4 Studien wurde in schräger Schnittführung untersucht, und in keiner Arbeit wurde eine Korrektur für die Schallgeschwindigkeit durchgeführt. Schlussfolgerung: Wir konnten zeigen, dass in der Mehrzahl der Studien, die in den letzten 10 Jahren zum Thema US-gestützte Knorpeldicke-Messung publiziert wurden, die Knorpeldicke systematisch unterschätzt wurde, da die zum Knorpel gehörende Grenzschicht nicht mitgemessen wurde. Da der Knorpel relativ dünn ist, ist dieser Fehler beträchtlich. Einige Autoren überschätzten die Knorpeldicke, indem sie mit schrägen Schnittführungen arbeiteten. Bei vielen Untersuchern kommt es durch fehlende Korrektur für die hohe Schallgeschwindigkeit im Knorpel zu einer systematischen Unterschätzung der Knorpeldicke. Background: Theoretically, the high spatial resolution of US makes it well suited to monitor the decrease in articular cartilage thickness in osteoarthritis. A requirement is, however, that the borders of the cartilage are correctly identified and that the cartilage is measured under orthogonal insonation. If US measurements are compared to measurements with other techniques, they should be corrected for the higher sound speed in cartilage. Purpose: To study whether investigators correctly identify the articular cartilage, whether they insonate orthogonally, and whether they correct for sound speed. Materials and Methods: A literature search limited to the last 10 years of studies applying US to measure cartilage thickness. Results: 15 studies were identified and they referred to another 8 studies describing methods of thickness measurement. 11 of the 15 studies identified the superficial cartilage border incorrectly, and 6 applied oblique insonation. 2 of the 15 studies corrected for sound speed. Of the further 8 studies, one might correctly identify the superficial cartilage border, 4 applied oblique insonation, and none corrected for sound speed. Conclusion: We found that the majority of studies over the last 10 years, evaluating articular cartilage thickness with US, underestimated the cartilage thickness by not including the leading interface as part of the cartilage. Since the cartilage is relatively thin, this error is substantial. Some investigators also overestimated cartilage thickness by using oblique insonation of the cartilage. By not correcting for the high sound speed in cartilage, most investigators underestimated the cartilage thickness.
- 30 March 2010
- Vol. 28 (1) , 103-13
Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy.
This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given in relevant sections. Ultrasound guided treatments where the Doppler result is used as a guide are mentioned and discussed.
- 30 March 2010
- Vol. 28 (1) , 103-13
Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy.
This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given in relevant sections. Ultrasound guided treatments where the Doppler result is used as a guide are mentioned and discussed.
- 31 January 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 69 (1) , 93-101
Signal intensity of normal breast tissue at MR mammography on midfield: Applying a random coefficient model evaluating the effect of doubling the contrast dose
- 31 January 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 69 (1) , 93-101
Signal intensity of normal breast tissue at MR mammography on midfield: Applying a random coefficient model evaluating the effect of doubling the contrast dose
- 1 January 2009
- Vol. 19 (1) , 12-8
Vascular response to ischemia in the feet of falanga torture victims and normal controls--color and spectral Doppler findings.
To investigate whether signs of chronic compartment syndrome could be found in plantar muscles of falanga torture victims with painful feet and impaired gait. The hypothesis was that the muscular vascular response to two minutes ischemia would be decreased in torture victims compared to controls. On color Doppler this would be seen as less color after ischemia and on spectral Doppler as elevated resistive index (RI). Ten male torture victims from the Middle East and nine age, sex and ethnically matched controls underwent Doppler examination of the abductor hallucis and flexor digitorum brevis muscles before and after two minutes ischemia induced with a pressure cuff over the malleoli. The color Doppler findings were quantified with the color fraction (CF) before and after ischemia. On spectral Doppler the resistive index was measured once before and three consecutive times after ischemia. Both torture victims and controls responded to ischemia with an increased CF. There was no difference between torture victims and controls. With spectral Doppler all subjects had an RI of 1.0 before ischemia. After ischemia, in nearly all subjects and all muscles the first RI was lowest, the second was higher and the third was highest indicating that the response to ischemia was disappearing as measurements were made. There was a trend that the first RI was higher in torture victims than in controls. The study was not able to confirm the presence of chronic compartment syndrome. However, the trend in RI still supports the hypothesis. The negative findings may be due to inadequate design where the CF and RI were measured in one setting, perhaps resulting in both methods being applied imperfectly. The response to ischemia seems short-lived and we suggest that the Doppler methods may be re-evaluated with separate ischemic phases for CF and RI.
- 1 January 2009
- Vol. 19 (1) , 12-8
Vascular response to ischemia in the feet of falanga torture victims and normal controls--color and spectral Doppler findings.
To investigate whether signs of chronic compartment syndrome could be found in plantar muscles of falanga torture victims with painful feet and impaired gait. The hypothesis was that the muscular vascular response to two minutes ischemia would be decreased in torture victims compared to controls. On color Doppler this would be seen as less color after ischemia and on spectral Doppler as elevated resistive index (RI). Ten male torture victims from the Middle East and nine age, sex and ethnically matched controls underwent Doppler examination of the abductor hallucis and flexor digitorum brevis muscles before and after two minutes ischemia induced with a pressure cuff over the malleoli. The color Doppler findings were quantified with the color fraction (CF) before and after ischemia. On spectral Doppler the resistive index was measured once before and three consecutive times after ischemia. Both torture victims and controls responded to ischemia with an increased CF. There was no difference between torture victims and controls. With spectral Doppler all subjects had an RI of 1.0 before ischemia. After ischemia, in nearly all subjects and all muscles the first RI was lowest, the second was higher and the third was highest indicating that the response to ischemia was disappearing as measurements were made. There was a trend that the first RI was higher in torture victims than in controls. The study was not able to confirm the presence of chronic compartment syndrome. However, the trend in RI still supports the hypothesis. The negative findings may be due to inadequate design where the CF and RI were measured in one setting, perhaps resulting in both methods being applied imperfectly. The response to ischemia seems short-lived and we suggest that the Doppler methods may be re-evaluated with separate ischemic phases for CF and RI.
- 1 January 2009
- Vol. 19 (1) , 19-26
Clinical performance diagnosing alleged exposure to falanga--a phantom study.
Falanga torture involves repetitive blunt trauma to the soles of the feet and typically leaves few detectable changes. Reduced elasticity in the heel pads has been reported as characteristic sequelae and palpatory testing of heel pad elasticity is therefore part of medicolegal assessment of alleged torture victims. The goal was to test the accuracy of two experienced investigators in determining whether a heel pad model was soft, medium or hard. The skin-to-bone distance in the models varied within the human range. Two blinded investigators independently palpated nine different heel pad models with three different elasticities combined with three different skin-to-bone distances in five consecutive trials and categorized the models as soft, medium or hard. Two experienced investigators were able to identify three known elasticities correctly in approximately two thirds of the cases. The skin-to-bone distance affected the accuracy. The use of clinical examination in documenting alleged exposure to torture warrants a high diagnostic accuracy of the applied tests. The study implies that palpatory testing of the human heel pad may not meet this demand. It is therefore recommended that a device able to perform an accurate measurement of the viscous-elastic properties of the heel pad be developed.
- 1 January 2009
- Vol. 19 (1) , 19-26
Clinical performance diagnosing alleged exposure to falanga--a phantom study.
Falanga torture involves repetitive blunt trauma to the soles of the feet and typically leaves few detectable changes. Reduced elasticity in the heel pads has been reported as characteristic sequelae and palpatory testing of heel pad elasticity is therefore part of medicolegal assessment of alleged torture victims. The goal was to test the accuracy of two experienced investigators in determining whether a heel pad model was soft, medium or hard. The skin-to-bone distance in the models varied within the human range. Two blinded investigators independently palpated nine different heel pad models with three different elasticities combined with three different skin-to-bone distances in five consecutive trials and categorized the models as soft, medium or hard. Two experienced investigators were able to identify three known elasticities correctly in approximately two thirds of the cases. The skin-to-bone distance affected the accuracy. The use of clinical examination in documenting alleged exposure to torture warrants a high diagnostic accuracy of the applied tests. The study implies that palpatory testing of the human heel pad may not meet this demand. It is therefore recommended that a device able to perform an accurate measurement of the viscous-elastic properties of the heel pad be developed.
- 1 January 2009
- Vol. 19 (1) , 33-40
Long-term consequences of falanga torture--what do we know and what do we need to know?
The long-term consequences of falanga are probably the best described consequences of exposure to specific forms of physical torture. Theories about casual lesions in the peripheral tissues of the feet have been put forward based on clinical observations along with international guidelines for the clinical assessment, but still knowledge is needed in several areas. A review of the literature on falanga is presented, mainly focusing on the clinical aspects and possible lesions caused by this specific form of torture that may influence the overall management of the condition. Finally, the article closes with a call for future research, which is needed in order to advance a knowledge-based development of the applied clinical practice.
- 1 January 2009
- Vol. 19 (1) , 33-40
Long-term consequences of falanga torture--what do we know and what do we need to know?
The long-term consequences of falanga are probably the best described consequences of exposure to specific forms of physical torture. Theories about casual lesions in the peripheral tissues of the feet have been put forward based on clinical observations along with international guidelines for the clinical assessment, but still knowledge is needed in several areas. A review of the literature on falanga is presented, mainly focusing on the clinical aspects and possible lesions caused by this specific form of torture that may influence the overall management of the condition. Finally, the article closes with a call for future research, which is needed in order to advance a knowledge-based development of the applied clinical practice.
- 1 October 2008
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 15 (7) , 437-442
Diagnostic accuracy of heel pad palpation – A phantom study
- 1 October 2008
- Published by Elsevier in Journal of Forensic and Legal Medicine
- Vol. 15 (7) , 437-442
Diagnostic accuracy of heel pad palpation – A phantom study