SMShigehiro Morikawa

Shigehiro Morikawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shigehiro Morikawa has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 January 2016
      • Vol. 220, 215-8

    Active and Passive Haptic Training Approaches in VR Laparoscopic Surgery Training.

    by Takafumi Marutani, Toma Kato, Kazuyoshi Tagawa, Hiromi T Tanaka, Masaru Komori, Yoshimasa Kurumi, Shigehiro Morikawa

    Laparoscopic surgery has become a widely performed surgery as it is one of the most common minimally invasive surgeries. Doctors perform the surgery by manipulating thin and long surgical instruments precisely with the assistance of laparoscopic video with limited field of view. The power control of the instruments' tip is especially very important, because excessive power may damage internal organs. The training of this surgical technique is mainly supervised by an expert in hands-on coaching program. However, it is difficult for the experts to spend sufficient time for coaching. Therefore, we aim to teach the expert's hand movements in laparoscopic surgery to trainees using VR-based simulator, which is equipped with a guidance force display device. To realize the system, we propose two haptic training approaches for transferring the expert's hand movements to the trainee. One is active training, and the other is passive training. The former approach shows the expert's movements only when the trainee makes large errors while the latter shows the expert's movements continuously. In this study, we validate the applicability of these approaches through tasks in VR laparoscopic surgery training simulator, and identify the differences between these approaches.


    • 1 January 2016
      • Vol. 220, 403-6

    Evaluation of Network-Based Minimally Invasive VR Surgery Simulator.

    by Kazuyoshi Tagawa, Hiromi T Tanaka, Yoshimasa Kurumi, Masaru Komori, Shigehiro Morikawa

    In this paper, we report a result of an experiment of a field trial of our network-based minimally invasive surgery simulator. In our previous paper, we proposed a network-based visuohaptic surgery training system for laparoscopic surgery. In addition, we proposed a volume-based haptic communication approach, which allows participants at remote sites on the network to simultaneously interact with the same target object in virtual environments presented by multi-level computer performance systems, by only exchanging a small set of manipulation parameters for the target object and additional packet for synchronization of status of binary tree and deformation of shared volume model. We implemented the approach into our network-based surgery simulator, and field trial of the simulator at three locations was performed.

    • 1 January 2014
      • Vol. 196, 192-6

    Evaluation of haptic teaching approaches for laparoscopic surgery training.

    by Toma Kato, Kazuyoshi Tagawa, Takafumi Marutani, Hiromi Tanaka, Masaru Komori, Yoshimasa Kurumi, Shigehiro Morikawa

    Laparoscopic surgery, one type of minimally invasive surgery (MIS) is a very important surgery technique which requires advanced surgical technique. At present, expert one-on-one teaching mainly supports the training of these advanced surgical techniques. However, time constraints prevent experts spending the amount of time desired for this training. Therefore, we aim to support training using a VR-based laparoscopic surgery simulator equipped with a guidance force display. This increases the amount of training a trainee can avail of while at the same time allow the expert and the trainee to increase the quality of the limited one-to-one time together. The first step of our research is to investigate approaches that displays the guidance force to teach experts hand movements. In this study, we used two guidance force-display approaches: Instrument-guiding approach and Hand-guiding approach. Through evaluative experiments, we found that the Hand-guiding approach is more suitable for skill transfer than the Instrument-guiding approach in particular tasks. The results are described below.

    • 1 January 2013
      • Vol. 184, 431-5

    Laparoscopic surgery simulator using first person view and guidance force.

    by Kazuyoshi Tagawa, Hiromi T Tanaka, Yoshimasa Kurumi, Masaru Komori, Shigehiro Morikawa

    In general, minimally invasive surgery is seen as the most difficult surgery because there is limited field of view with an endoscope and force sensation from surgical instruments such as forceps is poor. Especially in early clinical education for medical students, a virtual reality surgical simulator would be an effective tool. In this paper, we propose a visuohaptic surgery training system for laparoscopical techniques. We recorded a video from a first person point of view of the instructor (expert). And we also recorded operation information (i.e. trajectory) of surgical instruments of the instructor. Then, we displayed the recorded video and the guidance force to trainees. We constructed a prototype surgery training system and the effectiveness of our approach was confirmed.


  • Development of a novel 19F MRI probe for detecting amyloid deposition in Alzheimer's disease

    by Daijiro Yanagisawa, Shigehiro Morikawa, Hiroyasu Taguchi, Akihiko Shiino, Toshiro Inubushi, Ikuo Tooyama

    • 1 July 2006
      • Vol. 33  (7) , 951-7

    [Plasma platinum concentration and anti-tumor effects after intra-arterial infusion of lipiodol-CDDP suspension evaluation with VX 2 rabbit liver cancer model and 7.0 Tesla MRI system].

    by Akinaga Sonoda, Norihisa Nitta, Shinichi Ohta, Ryuta Itoh, Masashi Takahashi, Kiyoshi Murata, Shigehiro Morikawa, Toshiro Inubushi, Yoshihiro Miyagawa, Michie Takamori, et al.

    To evaluate the usefulness of combination chemotherapy with cisplatin powder, which was newly designed for intra-arterial infusion (IA CALL) and lipiodol, for the VX 2 liver cancer model of the rabbit, sequential change of the plasma platinum concentration within the first 24 hours, as well as the tissue platinum concentration at 24 hours was measured after intra-arterial infusion of IA CALL. The infused materials were either IA CALL alone (C) or the combination of lipiodol+IA CALL (CL). In addition,the reduction rate of the VX 2 tumor was calculated among four therapeutic groups (C, CL, lipiodol alone (L), and saline alone (S)) after one week of intra-arterial infusion on the basis of 7.0 Tesla MR images. Total plasma platinum concentrations within the first 24 hours were kept low in group CL. No increase in the tissue platinum concentration in group CL was observed. On the other hand, the tumor reduction rate tended to be higher in group CL (group CL>group L=group C>group S). These results suggested that the intra-arterial infusion of IA CALL with lipiodol is more effective than that of IA CALL alone.


    • 1 October 2003
      • Vol. 107  (10) , 571-7

    [Localization of glucose and sorbitol in incubated bovine lenses using chemical shift imaging].

    by Jiro Nakamura, Tomoko Sawada, Yasuhiro Nishida, Kazutaka Kani, Ryohei Okamoto, Shigehiro Morikawa, Toshiro Inubushi

    To use chemical shift imaging (CSI) to measure the metabolic changes in glucose metabolites in bovine lenses incubated in tissue culture medium 199(TCM 199) with a high concentration of glucose and to evaluate the viability of this method. We detected an accumulation of 13C-labeled glucose and sorbitol in the bovine lenses incubated in TCM 199 containing 50 mM glucose-1-13C for 1, 2, 4, or 6 days using a 2 T CSI Omega system. 1H-13C gradient-selected heteronuclear multiple-quantum coherence (GH-HMQC) in nuclear magnetic resonance (NMR), an indirect method of detecting nuclei in low sensitivity by 1H NMR, was used to observe 13C-enriched metabolites in the bovine lens in vivo. We found an accumulation of 13C-labeled glucose and sorbitol using the 2 T CSI Omega system. The level of glucose increased rapidly in the posterior segment of the lens as well as the anterior segment at one day after the beginning of incubation. Then it diminished gradually, and could no longer be detected on the 6th day after the start of incubation possibly because of the breakdown of the cell membrane. The levels of sorbitol increased in the anterior area and the equator of the lens one day after the beginning of incubation, and remained unchanged for 6 days. We encountered many problems especially with the imaging resolution (consequently the time for measurement was prolonged), but this approach may be useful for non-invasive monitoring of 13C-labeled compounds. We believe this method will be especially useful for detecting various metabolites in vivo.


  • Offset-Type Assistive Devices for Image Plane Navigation in Real-Time MR Image Guided Surgery

    by Shigehiro Morikawa, Toshiro Inubushi, Yoshimasa Kurumi, Shigeyuki Naka, Koichiro Sato, Nobuhiko Hata, Viswanathan Seshan, Hasnine A Haque

  • Integration of Customized Navigation Software for Real-Time MR Image-Guided Surgery

    by Shigehiro Morikawa, Toshiro Inubushi, Yoshimasa Kurumi, Shigeyuki Naka, Koichiro Sato, Akihiko Shiino, Nobuhiko Hata, Viswanathan Seshan, Hasnine A Haque