Takao Tsuda
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takao Tsuda has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Kinji Ohno
Graduate School of Nutritional Sciences, Nagoya University of Arts and Sciences
3 shared publications Makoto Tsunoda
Graduate School of Pharmaceutical Sciences, University of Tokyo
3 shared publications- Masaaki Hirayama
Department of Occupational Therapy, Chubu University College of Life and Health Sciences, Kasugai, Japan
3 shared publications Hiroshi Ito
1 shared publicationJun-Ichi Takeda
Division of Neurogenetics, Center for Neurological Diseases and Cancer, Nagoya University Graduate School of Medicine
1 shared publicationKatsumi Hirai
1 shared publication
Latest Publications
- Open Access
- 20 October 2019
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 40 (3) , 149-155
Application of Skin Gas GC/MS Analysis for Prediction of the Severity Scale of Parkinson’s Disease
Parkinson’s disease (PD) is diagnosed by neurological examinations, as well as by scintigraphy for the dopamine transporter and metaiodobenzylguanidine (MIBG). We studied possible application of the skin gas in diagnosis of PD. We analyzed chemical substances emanated from the skin by gas chromatograph/mass spectrometer (GC/MS) after on-line-pre-concentrator. We analyzed the skin gas in 61 PD patients and 61 controls. The GC/MS chromatograms were sectionalized every 30 sec. The retention time drift was shifted every 5 sec, and a similarity coefficient (Z score) between a reference chromatogram and each shifted chromatogram was calculated. Chromatograms with high Z scores were excluded from our analysis. Models were made with partial least square (PLS), support vector machine (SVM), and support vector regression (SVR) analyses. PLS modeling to predict the Unified Parkinson’s Disease Rating Scale part 3 (UPDRS3), representing motor deficits in PD, with all the detected mass numbers yielded 50 mass numbers with high PLS coefficients. Among the 50 mass numbers, nine mass numbers (m/e 48, 63, 67, 70, 81, 93, 96, 104, and 105) had dependable signal-to-noise ratios. We then generated an SVM model to differentiate PD and controls. Our SVM model had a sensitivity of 90.2% and a specificity of 85.2% by leave-one-out cross-validation (LOOCV) analysis. We next generated an SVR model to predict UPDRS3 with the nine mass numbers, and obtained a Pearson’s correlation coefficient of 0.834. LOOCV analysis of our SVR model similarly gave rise to a correlation coefficient of 0.710. We propose that chemical substances in the skin gas potentially serve as biomarkers for PD.
- 20 October 2019
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 40 (3) , 149-155
Open AccessApplication of Skin Gas GC/MS Analysis for Prediction of the Severity Scale of Parkinson’s Disease
Parkinson’s disease (PD) is diagnosed by neurological examinations, as well as by scintigraphy for the dopamine transporter and metaiodobenzylguanidine (MIBG). We studied possible application of the skin gas in diagnosis of PD. We analyzed chemical substances emanated from the skin by gas chromatograph/mass spectrometer (GC/MS) after on-line-pre-concentrator. We analyzed the skin gas in 61 PD patients and 61 controls. The GC/MS chromatograms were sectionalized every 30 sec. The retention time drift was shifted every 5 sec, and a similarity coefficient (Z score) between a reference chromatogram and each shifted chromatogram was calculated. Chromatograms with high Z scores were excluded from our analysis. Models were made with partial least square (PLS), support vector machine (SVM), and support vector regression (SVR) analyses. PLS modeling to predict the Unified Parkinson’s Disease Rating Scale part 3 (UPDRS3), representing motor deficits in PD, with all the detected mass numbers yielded 50 mass numbers with high PLS coefficients. Among the 50 mass numbers, nine mass numbers (m/e 48, 63, 67, 70, 81, 93, 96, 104, and 105) had dependable signal-to-noise ratios. We then generated an SVM model to differentiate PD and controls. Our SVM model had a sensitivity of 90.2% and a specificity of 85.2% by leave-one-out cross-validation (LOOCV) analysis. We next generated an SVR model to predict UPDRS3 with the nine mass numbers, and obtained a Pearson’s correlation coefficient of 0.834. LOOCV analysis of our SVR model similarly gave rise to a correlation coefficient of 0.710. We propose that chemical substances in the skin gas potentially serve as biomarkers for PD.
- 2 April 2016
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 6 (2) , 423-431
Serum Tyrosine-to-Phenylalanine Ratio is Low in Parkinson’s Disease
Background: Noninvasive biomarkers for Parkinson’s disease (PD) are currently unavailable. Objective: To search for a biomarker unique to PD in sweat and serum. Methods: Sweat samples in 42 PD patients and 16 controls were analyzed using liquid chromatography/mass spectrometry (LC/MS). The principal component analysis (PCA) and the orthogonal projections to latent structures (OPLS) analysis were employed. Serum Phe and Tyr levels were determined using the HPLC-fluorescence detection system in 28 de novo PD patients, 52 L-Dopa-treated PD patients, and 27 controls. Results: PCA and OPLS analyses of LC/MS of sweat samples revealed that Tyr, Phe, Leu (Ile), and Asp have high effect sizes to differentiate PD and controls. As Phe and Tyr are precursors of dopamine, we quantified the serum Phe and Tyr levels in de novo and treated PD patients, as well as in controls. Phe was high in de novo patients, but not in treated patients. In contrast, Tyr tended to be low in treated patients, but not in de novo patients. Tyr/Phe ratios were lower in both de novo and treated patients than in controls. The Tyr/Phe ratios were all higher than 0.82 in controls, whereas 49% of the de novo and treated patients had Tyr/Phe ratios less than 0.82. The low Tyr/Phe ratios were associated with male patients and low doses of entacapone. However, Tyr/Phe ratios were not different between male and female patients, and between patients with and without entacapone. Conclusions: The low serum Tyr/Phe ratio differentiates PD from controls with sensitivity = 0.49, specificity = 1.00, positive predictive value = 1.00, and negative predictive value = 0.40.
- 2 April 2016
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 6 (2) , 423-431
Serum Tyrosine-to-Phenylalanine Ratio is Low in Parkinson’s Disease
Background: Noninvasive biomarkers for Parkinson’s disease (PD) are currently unavailable. Objective: To search for a biomarker unique to PD in sweat and serum. Methods: Sweat samples in 42 PD patients and 16 controls were analyzed using liquid chromatography/mass spectrometry (LC/MS). The principal component analysis (PCA) and the orthogonal projections to latent structures (OPLS) analysis were employed. Serum Phe and Tyr levels were determined using the HPLC-fluorescence detection system in 28 de novo PD patients, 52 L-Dopa-treated PD patients, and 27 controls. Results: PCA and OPLS analyses of LC/MS of sweat samples revealed that Tyr, Phe, Leu (Ile), and Asp have high effect sizes to differentiate PD and controls. As Phe and Tyr are precursors of dopamine, we quantified the serum Phe and Tyr levels in de novo and treated PD patients, as well as in controls. Phe was high in de novo patients, but not in treated patients. In contrast, Tyr tended to be low in treated patients, but not in de novo patients. Tyr/Phe ratios were lower in both de novo and treated patients than in controls. The Tyr/Phe ratios were all higher than 0.82 in controls, whereas 49% of the de novo and treated patients had Tyr/Phe ratios less than 0.82. The low Tyr/Phe ratios were associated with male patients and low doses of entacapone. However, Tyr/Phe ratios were not different between male and female patients, and between patients with and without entacapone. Conclusions: The low serum Tyr/Phe ratio differentiates PD from controls with sensitivity = 0.49, specificity = 1.00, positive predictive value = 1.00, and negative predictive value = 0.40.
- 1 March 2015
- Published by Elsevier in Clinica Chimica Acta
- Vol. 442, 52-55
Noninvasive monitoring of plasma l-dopa concentrations using sweat samples in Parkinson's disease
- 1 March 2015
- Published by Elsevier in Clinica Chimica Acta
- Vol. 442, 52-55
Noninvasive monitoring of plasma l-dopa concentrations using sweat samples in Parkinson's disease
- Open Access
- 1 January 2015
- Published by Alkhaer Publications in International Journal of Sciences
- Vol. 1 (8) , 37-44
Acetone and 6-Methyl-5-Hepten-2-One in Skin Gas Increase during Hand-Grip Exercise
The present study investigated the effect of dynamic handgrip exercise on acetone, 6-methyl-5-hepten-2-one, acetaldehyde, and hexanal levels in skin gas. Participants in this experiment consisted of six healthy males. Skin gas was collected two times. First, skin gas during rest (i.e., before the exercise) was collected for 3 min into the sampling bag. Next, the exercise using a handgrip exercise instrument was performed. The hand performed a dynamic handgrip exercise for 3 min inside the sampling bag, exerting one 30 kg contraction per second. The blood flow at the end of the handgrip exercise increased by about 1.4 times that before exercise and then decreased to basal levels immediately thereafter. Acetone and 6-methyl-5-hepten-2-one concentrations after exercise significantly increased relative to basal levels. Significant differences were not observed in acetaldehyde and hexanal concentrations between at rest and after handgrip exercise. The amount of acetone and 6-methyl-5-hepten-2-one released from forearm skin increased during dynamic handgrip exercise. Acetaldehyde and hexanal levels did not increase during exercise compared with levels at rest.
- 1 January 2015
- Published by Alkhaer Publications in International Journal of Sciences
- Vol. 1 (8) , 37-44
Open AccessAcetone and 6-Methyl-5-Hepten-2-One in Skin Gas Increase during Hand-Grip Exercise
The present study investigated the effect of dynamic handgrip exercise on acetone, 6-methyl-5-hepten-2-one, acetaldehyde, and hexanal levels in skin gas. Participants in this experiment consisted of six healthy males. Skin gas was collected two times. First, skin gas during rest (i.e., before the exercise) was collected for 3 min into the sampling bag. Next, the exercise using a handgrip exercise instrument was performed. The hand performed a dynamic handgrip exercise for 3 min inside the sampling bag, exerting one 30 kg contraction per second. The blood flow at the end of the handgrip exercise increased by about 1.4 times that before exercise and then decreased to basal levels immediately thereafter. Acetone and 6-methyl-5-hepten-2-one concentrations after exercise significantly increased relative to basal levels. Significant differences were not observed in acetaldehyde and hexanal concentrations between at rest and after handgrip exercise. The amount of acetone and 6-methyl-5-hepten-2-one released from forearm skin increased during dynamic handgrip exercise. Acetaldehyde and hexanal levels did not increase during exercise compared with levels at rest.
- Open Access
- 15 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (19) , 5161-5164
A simple analytical method involving the use of a monolithic silica disk-packed spin column and HPLC-ECD for determination of l-DOPA in plasma of patients with Parkinson's disease
L-DOPA ( L-3,4-dihydroxyphenylalanine) is commonly used in the treatment of Parkinson's disease. Monitoring the concentration of L-DOPA in human plasma will enable dose optimization, but is rarely performed because current quantification methods are tedious and time-consuming. In this study, a simple method for the determination of L-DOPA in the plasma of patients with Parkinson's disease was developed. A monolithic silica disk-packed spin column with a phenylboronate moiety, which forms stable anionic complexes with the cis-hydroxyl groups of L-DOPA, was used to extract L-DOPA from plasma with extraction recoveries exceeding 90%. The extracted L-DOPA was then separated on a reversed-phase column and detected electrochemically with a boron-doped diamond electrode. The method, which has a limit of detection of 10 fmol, was then successfully applied for the determination of L-DOPA in the plasma of healthy volunteers and patients with Parkinson's disease.
- 15 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (19) , 5161-5164
Open AccessA simple analytical method involving the use of a monolithic silica disk-packed spin column and HPLC-ECD for determination of l-DOPA in plasma of patients with Parkinson's disease
L-DOPA ( L-3,4-dihydroxyphenylalanine) is commonly used in the treatment of Parkinson's disease. Monitoring the concentration of L-DOPA in human plasma will enable dose optimization, but is rarely performed because current quantification methods are tedious and time-consuming. In this study, a simple method for the determination of L-DOPA in the plasma of patients with Parkinson's disease was developed. A monolithic silica disk-packed spin column with a phenylboronate moiety, which forms stable anionic complexes with the cis-hydroxyl groups of L-DOPA, was used to extract L-DOPA from plasma with extraction recoveries exceeding 90%. The extracted L-DOPA was then separated on a reversed-phase column and detected electrochemically with a boron-doped diamond electrode. The method, which has a limit of detection of 10 fmol, was then successfully applied for the determination of L-DOPA in the plasma of healthy volunteers and patients with Parkinson's disease.
- Open Access
- 12 March 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (3) , 479-481
Instrumentation of High Temperature and Pressure Reaction System with Continuous Flow and Its Hyphenation to a Liquid Chromatograph
A continuous flow-type hydrothermal reaction system, in which both temperature and pressure were rapidly and dynamically controlled, was constructed. It is called a real time high temperature and pressure reaction system (RT-HighTP). The RT-HighTP was hyphenated with liquid chromatograph (RT-HighTP-LC) to achieve prompt analysis of the reaction products. The RT-HighTP system produced stable pressure under the supercritical and subcritical phases (%RSD < 3%). The RT-HighTP-LC was able to change the hydrothermal condition rapidly. The hydrothermal products under four conditions were analyzed within 70 min. Further, the hydrothermal products of lignin was easily taken out using the sample collecting loop and analyzed by an external instrument of GC/MS.
- 12 March 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (3) , 479-481
Open AccessInstrumentation of High Temperature and Pressure Reaction System with Continuous Flow and Its Hyphenation to a Liquid Chromatograph
A continuous flow-type hydrothermal reaction system, in which both temperature and pressure were rapidly and dynamically controlled, was constructed. It is called a real time high temperature and pressure reaction system (RT-HighTP). The RT-HighTP was hyphenated with liquid chromatograph (RT-HighTP-LC) to achieve prompt analysis of the reaction products. The RT-HighTP system produced stable pressure under the supercritical and subcritical phases (%RSD < 3%). The RT-HighTP-LC was able to change the hydrothermal condition rapidly. The hydrothermal products under four conditions were analyzed within 70 min. Further, the hydrothermal products of lignin was easily taken out using the sample collecting loop and analyzed by an external instrument of GC/MS.