Petra S. Dittrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petra S. Dittrich has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Manz
KIST Europe, 66123 Saarbrücken, Germany
4 shared publications Barbara Müller
Experimental Biophysics Group, Max-Planck-Institute for Biophysical Chemistry, Am Fassberg 11, Göttingen, Germany
1 shared publicationMartin Heule
Microsystems Laboratory, Ecole Polytechnique Federale de Lausanne, EPFL-STI-LMIS, CH-1015 Lausanne, Switzerland
1 shared publicationMichael Jahnz
Institute of Biophysics, Bio Tec, TU Dresden, Tatzberg 47–51, 01307 Dresden, Germany, Fax: (+49) 351-46340-342
1 shared publication- Petra Schwille
Department of Biophysics, Biotechnologisches Zentrum, Technische Universität Dresden, Tatzberg 47‐49, Dresden 01307 (Germany), Fax: (+49) 351‐46340342
1 shared publication - Petra Schwille
Technische Universität Dresden
1 shared publication
Latest Publications
- 2 April 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 137 (2) , 781-788
Microfluidic imaging: A novel concept for pixelation of chemical and biological samples
- 2 April 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 137 (2) , 781-788
Microfluidic imaging: A novel concept for pixelation of chemical and biological samples
- 2 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (4) , 488-493
On-chip extrusion of lipid vesicles and tubes through microsized apertures
In this work we present the formation of micrometre-sized lipid vesicles and tubes with perfectly homogeneous diameter and extraordinary length. The method is a novel approach for unconventional fabrication of soft-matter microstructured devices based on the combination of top-down and bottom-up fabrication processes. Photolithography techniques are applied to fabricate microsized apertures that provide the requirements to form lipid structures with predictable size and to align and guide the vesicles and tubes in microstructured channels. The formation is facilitated by self-assembly of polar lipids to a lipid membrane that is afterwards forced to undergo a shape transformation by extrusion through a microsized aperture. Both the geometrical restriction by the small aperture and the pressure difference between the top and bottom sides of the aperture determine the form and length of the vesicles and tubes. A strong pressure difference favors the formation of lipid tubes, while a low pressure difference results in the formation of vesicle bunches with spherical and cylindrical shapes. Potential applications for the formed lipid structures could be as microreactors and transport channels as well as in the construction of flexible microfluidic networks.
- 2 March 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (4) , 488-493
On-chip extrusion of lipid vesicles and tubes through microsized apertures
In this work we present the formation of micrometre-sized lipid vesicles and tubes with perfectly homogeneous diameter and extraordinary length. The method is a novel approach for unconventional fabrication of soft-matter microstructured devices based on the combination of top-down and bottom-up fabrication processes. Photolithography techniques are applied to fabricate microsized apertures that provide the requirements to form lipid structures with predictable size and to align and guide the vesicles and tubes in microstructured channels. The formation is facilitated by self-assembly of polar lipids to a lipid membrane that is afterwards forced to undergo a shape transformation by extrusion through a microsized aperture. Both the geometrical restriction by the small aperture and the pressure difference between the top and bottom sides of the aperture determine the form and length of the vesicles and tubes. A strong pressure difference favors the formation of lipid tubes, while a low pressure difference results in the formation of vesicle bunches with spherical and cylindrical shapes. Potential applications for the formed lipid structures could be as microreactors and transport channels as well as in the construction of flexible microfluidic networks.
- Top Cited Papers
- 1 March 2006
- Published by Springer Nature in Nature Reviews Drug Discovery
- Vol. 5 (3) , 210-218
Lab-on-a-chip: microfluidics in drug discovery
Miniaturization can expand the capability of existing bioassays, separation technologies and chemical synthesis techniques. Although a reduction in size to the micrometre scale will usually not change the nature of molecular reactions, laws of scale for surface per volume, molecular diffusion and heat transport enable dramatic increases in throughput. Besides the many microwell-plate- or bead-based methods, microfluidic chips have been widely used to provide small volumes and fluid connections and could eventually outperform conventionally used robotic fluid handling. Moreover, completely novel applications without a macroscopic equivalent have recently been developed. This article reviews current and future applications of microfluidics and highlights the potential of 'lab-on-a-chip' technology for drug discovery.
- 1 March 2006
- Published by Springer Nature in Nature Reviews Drug Discovery
- Vol. 5 (3) , 210-218
Top Cited PapersLab-on-a-chip: microfluidics in drug discovery
Miniaturization can expand the capability of existing bioassays, separation technologies and chemical synthesis techniques. Although a reduction in size to the micrometre scale will usually not change the nature of molecular reactions, laws of scale for surface per volume, molecular diffusion and heat transport enable dramatic increases in throughput. Besides the many microwell-plate- or bead-based methods, microfluidic chips have been widely used to provide small volumes and fluid connections and could eventually outperform conventionally used robotic fluid handling. Moreover, completely novel applications without a macroscopic equivalent have recently been developed. This article reviews current and future applications of microfluidics and highlights the potential of 'lab-on-a-chip' technology for drug discovery.
- 17 June 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (8) , 1771-1782
Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS?
Both single-molecule detection (SMD) methods and miniaturization technologies have developed very rapidly over the last ten years. By merging these two techniques, it may be possible to achieve the optimal requirements for the analysis and manipulation of samples on a single molecule scale. While miniaturized structures and channels provide the interface required to handle small particles and molecules, SMD permits the discovery, localization, counting and identification of compounds. Widespread applications, across various bioscience/analytical science fields, such as DNA-analysis, cytometry and drug screening, are envisaged. In this review, the unique benefits of single fluorescent molecule detection in microfluidic channels are presented. Recent and possible future applications are discussed.
- 17 June 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (8) , 1771-1782
Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS?
Both single-molecule detection (SMD) methods and miniaturization technologies have developed very rapidly over the last ten years. By merging these two techniques, it may be possible to achieve the optimal requirements for the analysis and manipulation of samples on a single molecule scale. While miniaturized structures and channels provide the interface required to handle small particles and molecules, SMD permits the discovery, localization, counting and identification of compounds. Widespread applications, across various bioscience/analytical science fields, such as DNA-analysis, cytometry and drug screening, are envisaged. In this review, the unique benefits of single fluorescent molecule detection in microfluidic channels are presented. Recent and possible future applications are discussed.
- 22 April 2005
- Published by Wiley in ChemBioChem
- Vol. 6 (5) , 811-814
A New Embedded Process for Compartmentalized Cell‐Free Protein Expression and On‐line Detection in Microfluidic Devices
- 22 April 2005
- Published by Wiley in ChemBioChem
- Vol. 6 (5) , 811-814
A New Embedded Process for Compartmentalized Cell‐Free Protein Expression and On‐line Detection in Microfluidic Devices
- 14 July 2004
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 6 (18) , 4416-4420
Studying reaction kinetics by simultaneous FRET and cross-correlation analysis in a miniaturized continuous flow reactor
In this study we present a refined optical detection technique for investigation of fast reactions based on confocal fluorescence spectroscopy in a miniaturized continuous flow (μCF) reactor. The special setup allows for simultaneous observation of the reaction on the basis of fluorescent resonance energy transfer (FRET) as an indicator of the reaction progress. Determination of the flow velocity via spatial fluorescence cross-correlation enables the conversion of spatial information, i.e. the position of the detection point, into the respective temporal information. To overcome the disadvantage of conventional continuous flow reactors of high sample consumption, we used a microfluidic chip allowing an economical expenditure of sample solution at low concentration, while the silicon/glass chip is perfectly adaptable to the confocal setup. Inside these channels, rapid, diffusion-based mixing under laminar flow conditions is performed at the crossing of three channels by squeezing the solutions into thin layers. Using this μCF device, we investigated the irreversible cleavage reaction of a double stranded DNA oligomer by the enzyme exonuclease III. The complementary DNA strands are stained with TAMRA and Cy 5 dye molecules, respectively, undergoing an energy transfer if both strands are annealed. The reduction of the Cy 5 fluorescence directly corresponds to the progress of the cleavage reaction.
- 14 July 2004
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 6 (18) , 4416-4420
Studying reaction kinetics by simultaneous FRET and cross-correlation analysis in a miniaturized continuous flow reactor
In this study we present a refined optical detection technique for investigation of fast reactions based on confocal fluorescence spectroscopy in a miniaturized continuous flow (μCF) reactor. The special setup allows for simultaneous observation of the reaction on the basis of fluorescent resonance energy transfer (FRET) as an indicator of the reaction progress. Determination of the flow velocity via spatial fluorescence cross-correlation enables the conversion of spatial information, i.e. the position of the detection point, into the respective temporal information. To overcome the disadvantage of conventional continuous flow reactors of high sample consumption, we used a microfluidic chip allowing an economical expenditure of sample solution at low concentration, while the silicon/glass chip is perfectly adaptable to the confocal setup. Inside these channels, rapid, diffusion-based mixing under laminar flow conditions is performed at the crossing of three channels by squeezing the solutions into thin layers. Using this μCF device, we investigated the irreversible cleavage reaction of a double stranded DNA oligomer by the enzyme exonuclease III. The complementary DNA strands are stained with TAMRA and Cy 5 dye molecules, respectively, undergoing an energy transfer if both strands are annealed. The reduction of the Cy 5 fluorescence directly corresponds to the progress of the cleavage reaction.