JRJ. E. Rotunda

J. E. Rotunda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. E. Rotunda has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • A. Romanyukha

    Department of Radiation Medicine , Georgetown University Medical Center , 3970 Reservoir Road NW, Washington, DC 20057 , USA

    1 shared publication
  • F. Hull

    Department of Radiation Medicine , Georgetown University Medical Center , 3970 Reservoir Road NW, Washington, DC 20057 , USA

    1 shared publication
  • I. Nita

    Thermo Fisher Scientific , One Thermo Fisher Way , Oakwood Village, OH 44146 , USA

    1 shared publication
  • K. J. Velbeck

    Thermo Fisher Scientific , One Thermo Fisher Way , Oakwood Village, OH 44146 , USA

    1 shared publication
  • L. Benevides

    The US Naval Dosimetry Center , Bethesda, MD 20889 , USA

    1 shared publication
  • M. Duffy

    Department of Radiation Medicine , Georgetown University Medical Center , 3970 Reservoir Road NW, Washington, DC 20057 , USA

    1 shared publication

Latest Publications

  • The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material

    by M. Moscovitch, L. Benevides, A. Romanyukha, F. Hull, M. Duffy, S. Voss, K. J. Velbeck, I. Nita, J. E. Rotunda

    The phototransferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼6 % in the dose range of 0.2 mGy–1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated.


  • Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P)

    by M. Ramlo, M. Moscovitch, J. E. Rotunda

    This paper describes further investigations and results in the reduction of residual signal in Harshaw TLD-100H, 600H and 700H (LiF:Mg,Cu,P). TLD-100H is an advanced, relatively new dosimetric material with near tissue-equivalence, flat energy response, and the ability to measure beta, photon and, more importantly, neutrons all from the same base material. The simple glow curve structure provides insignificant fade over extended dosimetric periods of up to 1 y. A criticism of the material has been the residual as compared with TLD-100 (LiF:Mg,Ti). We will show how high-temperature peaks cause the residual signal. We will also show how the various parameters and conditions of the residual measurement technique as well as the configuration of the sample affect the residual measurements. A brief description of the experimental paths taken during our investigation will be presented. We will show how we have reduced the high-temperature peaks of LiF:Mg,Cu,P in our manufacturing process while not affecting other dosimetric properties of this material. The improvements and material properties that need to be shown have been incorporated into our production processes. LiF:Mg,Cu,P stands as a premier choice for personal dosimetry and has been integrated into personal, environmental and extremity configurations of the Harshaw TLD family-line of products.