J. Daures
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
J. Daures has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Marc Bordy
CEA, LIST, DM21, Laboratoire National Henri Becquerel LNE/LNHB, F-91191 Gif sur Yvette, France
10 shared publications J. Gouriou
4 shared publicationsA. Ostrowsky
3 shared publications- Filip Vanhavere
European committee for standardization
3 shared publications - L. Donadille
Institute for Radiological Protection and Nuclear Safety (IRSN), BP 17, F-92262 Fontenay-aux-Roses, France
3 shared publications M. Denozière
3 shared publications
Latest Publications
- 10 December 2014
- Published by EDP Sciences in Revue française de métrologie
- No. 35,p. 15-23
Établissement de références en dose absorbée dans l’eau par calorimétrie dans l’eau au LNE-LNHB pour les rayons X de moyenne énergie.
- 10 December 2014
- Published by EDP Sciences in Revue française de métrologie
- No. 35,p. 15-23
Établissement de références en dose absorbée dans l’eau par calorimétrie dans l’eau au LNE-LNHB pour les rayons X de moyenne énergie.
- 1 December 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e136
Establishment of dosimetric references in small fields thanks to a new quantity of interest
- 1 December 2014
- Published by Elsevier in Physica Medica
- Vol. 30, e136
Establishment of dosimetric references in small fields thanks to a new quantity of interest
- 8 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (9) , 2787-2806
Comparison between absorbed dose to water standards established by water calorimetry at the LNE-LNHB and by application of international air-kerma based protocols for kilovoltage medium energy x-rays
Nowadays, the absorbed dose to water for kilovoltage x-ray beams is determined from standards in terms of air-kerma by application of international dosimetry protocols. New standards in terms of absorbed dose to water has just been established for these beams at the LNE-LNHB, using water calorimetry, at a depth of 2 cm in water in accordance with protocols. The aim of this study is to compare these new standards in terms of absorbed dose to water, to the dose values calculated from the application of four international protocols based on air-kerma standards (IAEA TRS-277, AAPM TG-61, IPEMB and NCS-10). The acceleration potentials of the six beams studied are between 80 and 300 kV with half-value layers between 3.01 mm of aluminum and 3.40 mm of copper. A difference between the two methods smaller than 2.1% was reported. The standard uncertainty of water calorimetry being below 0.8%, and the one associated with the values from protocols being around 2.5%, the results are in good agreement. The calibration coefficients of some ionization chambers in terms of absorbed dose to water, established by application of calorimetry and air-kerma based dosimetry protocols, were also compared. The best agreement with the calibration coefficients established by water calorimetry was found for those established with the AAPM TG-61 protocol.
- 8 April 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (9) , 2787-2806
Comparison between absorbed dose to water standards established by water calorimetry at the LNE-LNHB and by application of international air-kerma based protocols for kilovoltage medium energy x-rays
Nowadays, the absorbed dose to water for kilovoltage x-ray beams is determined from standards in terms of air-kerma by application of international dosimetry protocols. New standards in terms of absorbed dose to water has just been established for these beams at the LNE-LNHB, using water calorimetry, at a depth of 2 cm in water in accordance with protocols. The aim of this study is to compare these new standards in terms of absorbed dose to water, to the dose values calculated from the application of four international protocols based on air-kerma standards (IAEA TRS-277, AAPM TG-61, IPEMB and NCS-10). The acceleration potentials of the six beams studied are between 80 and 300 kV with half-value layers between 3.01 mm of aluminum and 3.40 mm of copper. A difference between the two methods smaller than 2.1% was reported. The standard uncertainty of water calorimetry being below 0.8%, and the one associated with the values from protocols being around 2.5%, the results are in good agreement. The calibration coefficients of some ionization chambers in terms of absorbed dose to water, established by application of calorimetry and air-kerma based dosimetry protocols, were also compared. The best agreement with the calibration coefficients established by water calorimetry was found for those established with the AAPM TG-61 protocol.
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1235-1238
Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
- 30 November 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (11) , 1235-1238
Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
- 30 June 2011
- Published by Elsevier in Physica Medica
- Vol. 27, S22
Establishment of references in terms of absorbed dose to water in MV X-ray beams for small radiation fields
- 30 June 2011
- Published by Elsevier in Physica Medica
- Vol. 27, S22
Establishment of references in terms of absorbed dose to water in MV X-ray beams for small radiation fields
- 17 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 37-42
Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulations
This work has been performed within the frame of the European Union ORAMED project (Optimisation of RAdiation protection for MEDical staff). The main goal of the project is to improve standards of protection for medical staff for procedures resulting in potentially high exposures and to develop methodologies for better assessing and for reducing, exposures to medical staff. The Work Package WP2 is involved in the development of practical eye-lens dosimetry in interventional radiology. This study is complementary of the part of the ENEA report concerning the calculations with the MCNP-4C code of the conversion factors related to the operational quantity Hp(3). In this study, a set of energy- and angular-dependent conversion coefficients (Hp(3)/Ka), in the newly proposed square cylindrical phantom made of ICRU tissue, have been calculated with the Monte-Carlo code PENELOPE and MCNP5. The Hp(3) values have been determined in terms of absorbed dose, according to the definition of this quantity, and also with the kerma approximation as formerly reported in ICRU reports. At a low-photon energy (up to 1 MeV), the two results obtained with the two methods are consistent. Nevertheless, large differences are showed at a higher energy. This is mainly due to the lack of electronic equilibrium, especially for small angle incidences. The values of the conversion coefficients obtained with the MCNP-4C code published by ENEA quite agree with the kerma approximation calculations obtained with PENELOPE. We also performed the same calculations with the code MCNP5 with two types of tallies: F6 for kerma approximation and *F8 for estimating the absorbed dose that is, as known, due to secondary electrons. PENELOPE and MCNP5 results agree for the kerma approximation and for the absorbed dose calculation of Hp(3) and prove that, for photon energies larger than 1 MeV, the transport of the secondary electrons has to be taken into account.
- 17 January 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 37-42
Monte Carlo determination of the conversion coefficients Hp(3)/Ka in a right cylinder phantom with 'PENELOPE' code. Comparison with 'MCNP' simulations
This work has been performed within the frame of the European Union ORAMED project (Optimisation of RAdiation protection for MEDical staff). The main goal of the project is to improve standards of protection for medical staff for procedures resulting in potentially high exposures and to develop methodologies for better assessing and for reducing, exposures to medical staff. The Work Package WP2 is involved in the development of practical eye-lens dosimetry in interventional radiology. This study is complementary of the part of the ENEA report concerning the calculations with the MCNP-4C code of the conversion factors related to the operational quantity Hp(3). In this study, a set of energy- and angular-dependent conversion coefficients (Hp(3)/Ka), in the newly proposed square cylindrical phantom made of ICRU tissue, have been calculated with the Monte-Carlo code PENELOPE and MCNP5. The Hp(3) values have been determined in terms of absorbed dose, according to the definition of this quantity, and also with the kerma approximation as formerly reported in ICRU reports. At a low-photon energy (up to 1 MeV), the two results obtained with the two methods are consistent. Nevertheless, large differences are showed at a higher energy. This is mainly due to the lack of electronic equilibrium, especially for small angle incidences. The values of the conversion coefficients obtained with the MCNP-4C code published by ENEA quite agree with the kerma approximation calculations obtained with PENELOPE. We also performed the same calculations with the code MCNP5 with two types of tallies: F6 for kerma approximation and *F8 for estimating the absorbed dose that is, as known, due to secondary electrons. PENELOPE and MCNP5 results agree for the kerma approximation and for the absorbed dose calculation of Hp(3) and prove that, for photon energies larger than 1 MeV, the transport of the secondary electrons has to be taken into account.
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 132-135
Use of Active Personal Dosemeters in Interventional Radiology: A Systematic Study in Laboratory Conditions
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 132-135
Use of Active Personal Dosemeters in Interventional Radiology: A Systematic Study in Laboratory Conditions
- 7 August 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 131 (1) , 87-92
Evaluation of the calibration procedure of active personal dosemeters for interventional radiology
An overview of the use of active personal dosemeters (APD) in interventional radiology is presented. It is based on the work done by the working package 7 of the CONRAD coordinated action supported by the EC within the frame of the 6th FP. This study was done in collaboration with the working package 4 of CONRAD to deal with the calculations required for studying the new calibration facility. The main requirements of the standard for the APD and the difficulties caused by the use of pulsed radiations are presented through the results of an intercomparison organised in a realistic calibration facility similar to the workplace situation in interventional radiology. The main characteristics of this facility are presented.
- 7 August 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 131 (1) , 87-92
Evaluation of the calibration procedure of active personal dosemeters for interventional radiology
An overview of the use of active personal dosemeters (APD) in interventional radiology is presented. It is based on the work done by the working package 7 of the CONRAD coordinated action supported by the EC within the frame of the 6th FP. This study was done in collaboration with the working package 4 of CONRAD to deal with the calculations required for studying the new calibration facility. The main requirements of the standard for the APD and the difficulties caused by the use of pulsed radiations are presented through the results of an intercomparison organised in a realistic calibration facility similar to the workplace situation in interventional radiology. The main characteristics of this facility are presented.
- 1 February 2008
- Published by Elsevier in Radiation Measurements
- Vol. 43 (2-6) , 565-570
Intercomparison on measurements of the quantity personal dose equivalent, (0.07), by extremity ring dosimeters in medical fields
- 1 February 2008
- Published by Elsevier in Radiation Measurements
- Vol. 43 (2-6) , 565-570
Intercomparison on measurements of the quantity personal dose equivalent, (0.07), by extremity ring dosimeters in medical fields