Paul A. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Paul A. Anderson has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Cathy S. Carlson
2 shared publicationsJeffrey P. Rouleau
2 shared publications- Alexander Richard Vaccaro
Rothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, USA
1 shared publication Ashish L. Oza
1 shared publicationJan Goffin
1 shared publication- Jeffrey C. Wang
Department of Orthopaedic Surgery, University of California at Los Angeles, Los Angeles, USA
1 shared publication
Latest Publications
- 1 April 2006
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (7) , 755-761
Biomechanics of Occipitocervical Fixation
A human cadaveric biomechanical study comparing occipital fixation techniques. To compare ranges of motion between midline and lateral occipital fixation and between rigid and nonrigid occipital fixation of an unstable craniocervical spine. New fixation techniques using rods and screws increase surgical choice on where fixation is placed onto the occiput. Lateral fixation theoretically gives improved resistance to deformation because of its increased effective moment arm and bilateral purchase. Midline fixation allows significantly longer screw purchase. This study compares these two fixation location. Cadaveric occipital cervical spine specimens were tested biomechanically intact and under six different fixation techniques. Range of motion between the skull and C2 at 1.5 N-m and 2 N-m bending moments was measured in flexion-extension, lateral bending, and axial rotation. Mechanical testing of different rod diameters and a reconstruction plate was performed and compared with biomechanical testing. Results were compared between the intact condition and all fixations, between the medial and lateral fixations, and between the rigid and nonrigid fixations by analysis of variance. The range of motion of all constructs was significantly reduced compared with intact. Significant differences between groups were only seen in lateral bending in fixation placed laterally. Mechanical testing demonstrated that construct stiffness was predicted by area moment of inertia of the rod and plate to a greater degree than variation in placement of occipital screws or locking of the implant. The choice of location of occipital fixation should be based more on the ease of use and instability pattern. The decreased stiffness of the newer small rod systems should be considered.
- 1 April 2006
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (7) , 755-761
Biomechanics of Occipitocervical Fixation
A human cadaveric biomechanical study comparing occipital fixation techniques. To compare ranges of motion between midline and lateral occipital fixation and between rigid and nonrigid occipital fixation of an unstable craniocervical spine. New fixation techniques using rods and screws increase surgical choice on where fixation is placed onto the occiput. Lateral fixation theoretically gives improved resistance to deformation because of its increased effective moment arm and bilateral purchase. Midline fixation allows significantly longer screw purchase. This study compares these two fixation location. Cadaveric occipital cervical spine specimens were tested biomechanically intact and under six different fixation techniques. Range of motion between the skull and C2 at 1.5 N-m and 2 N-m bending moments was measured in flexion-extension, lateral bending, and axial rotation. Mechanical testing of different rod diameters and a reconstruction plate was performed and compared with biomechanical testing. Results were compared between the intact condition and all fixations, between the medial and lateral fixations, and between the rigid and nonrigid fixations by analysis of variance. The range of motion of all constructs was significantly reduced compared with intact. Significant differences between groups were only seen in lateral bending in fixation placed laterally. Mechanical testing demonstrated that construct stiffness was predicted by area moment of inertia of the rod and plate to a greater degree than variation in placement of occipital screws or locking of the implant. The choice of location of occipital fixation should be based more on the ease of use and instability pattern. The decreased stiffness of the newer small rod systems should be considered.
- 1 August 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (8) , 1892-1901
What's New in Spine Surgery
An increasing number of prospective studies have established the efficacy of many cervical spine procedures. At the same time, complications and morbidity have been critically analyzed. Several of these studies regarding anterior fusion and laminoplasty will be reviewed. ### Outcomes Long-term follow-up with use of validated instruments and strict radiographic criteria are effective for evaluating surgical results. The Cervical Spine Research Society prospectively followed 181 patients for two years to assess the influence of plates on outcomes. In patients with single-level fusions, the use of a plate was associated with a significantly higher rate of successful fusion (94% compared with 73%). Rigid and translational plates were associated with better results than plates that only allowed the toggle of screw heads. Other studies of intervertebral fusion devices have demonstrated conflicting results. Carbon fiber-reinforced spacers used as stand-alone devices had results similar to allografts, whereas tantalum mesh implants had poor results that necessitated the discontinuation of a randomized study. Pulsed electromagnetic field stimulation has been shown to induce fusion in the lumbar spine and the healing of extremity nonunions. In a prospective, randomized study, pulsed electromagnetic field stimulation was associated with higher rates of successful cervical fusion (84% compared with 69%), although no significant differences in functional outcomes were noted. Interestingly, successful fusion, either with or without pulsed electromagnetic field stimulation, was significantly correlated with good clinical outcomes. Controversies still remain with regard to the approach (i.e., anterior or posterior) for treatment of cervical spondylotic myelopathy. In a randomized study comparing corpectomy and autograft fusion with laminoplasty, no differences were noted with regard to the rate of neurologic recovery or the range of motion of the neck. However, both groups had significant improvement in neurologic function. Axial pain was greater in the laminoplasty group. Complications in the anterior treatment group included dysphagia and pseudarthrosis, …
- 1 August 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (8) , 1892-1901
What's New in Spine Surgery
An increasing number of prospective studies have established the efficacy of many cervical spine procedures. At the same time, complications and morbidity have been critically analyzed. Several of these studies regarding anterior fusion and laminoplasty will be reviewed. ### Outcomes Long-term follow-up with use of validated instruments and strict radiographic criteria are effective for evaluating surgical results. The Cervical Spine Research Society prospectively followed 181 patients for two years to assess the influence of plates on outcomes. In patients with single-level fusions, the use of a plate was associated with a significantly higher rate of successful fusion (94% compared with 73%). Rigid and translational plates were associated with better results than plates that only allowed the toggle of screw heads. Other studies of intervertebral fusion devices have demonstrated conflicting results. Carbon fiber-reinforced spacers used as stand-alone devices had results similar to allografts, whereas tantalum mesh implants had poor results that necessitated the discontinuation of a randomized study. Pulsed electromagnetic field stimulation has been shown to induce fusion in the lumbar spine and the healing of extremity nonunions. In a prospective, randomized study, pulsed electromagnetic field stimulation was associated with higher rates of successful cervical fusion (84% compared with 69%), although no significant differences in functional outcomes were noted. Interestingly, successful fusion, either with or without pulsed electromagnetic field stimulation, was significantly correlated with good clinical outcomes. Controversies still remain with regard to the approach (i.e., anterior or posterior) for treatment of cervical spondylotic myelopathy. In a randomized study comparing corpectomy and autograft fusion with laminoplasty, no differences were noted with regard to the rate of neurologic recovery or the range of motion of the neck. However, both groups had significant improvement in neurologic function. Axial pain was greater in the laminoplasty group. Complications in the anterior treatment group included dysphagia and pseudarthrosis, …
- 1 November 2004
- Published by Elsevier in The Spine Journal
- Vol. 4 (6) , S303-S309
The Bryan Cervical Disc: wear properties and early clinical results
- 1 November 2004
- Published by Elsevier in The Spine Journal
- Vol. 4 (6) , S303-S309
The Bryan Cervical Disc: wear properties and early clinical results
- 1 October 2003
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (Supplement) , S186-S194
Wear Analysis of the Bryan Cervical Disc Prosthesis
In vitro wear testing of the Bryan® Cervical Disc prosthesis was performed in a cervical spine simulator. The biologic response was assessed in chimpanzee and goat animal models. Determine the wear characteristics of the Bryan disc. Large joint arthroplasties fail most commonly by wear and consequent formation of particulate material, which induces an inflammatory response. Therefore, measuring the wear characteristics of the new spinal disc replacements is important. Six prosthetic assembles were tested to 10 or 40 million cycles by load and motion and 3 additional assemblies were tested by load only in a cervical spine simulator. Any debris was examined using ASTM standards. The local biologic response to the prosthesis was examined in two chimpanzees. Nine goats were used to assess the biologic response in both local and distant tissues. Arthrodesis was performed on three additional control goats that received an allograft and an anterior cervical plate. Wear results: cervical spine simulators that applied the loads and motions associated with activities of daily living produced wear particulate at a rate of 1.2 mg per million cycles. Device height decreased 0.02 mm per million cycles with approximately 77% of this decrease due to gradual creep of the nucleus under the constant compressive load. Particles generated were granular in shape with a mean feret diameter of 3.9 μm. All animals tolerated placement of the Bryan disc. Wear debris was present in the periprosthetic and epidural spaces in some animals. However, no significant inflammatory response was observed. No wear material was found distant from the implant in draining lymph tissue, the liver, or the spleen. The Bryan disc has satisfactory wear characteristics and does not produce a significant inflammatory response.
- 1 October 2003
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (Supplement) , S186-S194
Wear Analysis of the Bryan Cervical Disc Prosthesis
In vitro wear testing of the Bryan® Cervical Disc prosthesis was performed in a cervical spine simulator. The biologic response was assessed in chimpanzee and goat animal models. Determine the wear characteristics of the Bryan disc. Large joint arthroplasties fail most commonly by wear and consequent formation of particulate material, which induces an inflammatory response. Therefore, measuring the wear characteristics of the new spinal disc replacements is important. Six prosthetic assembles were tested to 10 or 40 million cycles by load and motion and 3 additional assemblies were tested by load only in a cervical spine simulator. Any debris was examined using ASTM standards. The local biologic response to the prosthesis was examined in two chimpanzees. Nine goats were used to assess the biologic response in both local and distant tissues. Arthrodesis was performed on three additional control goats that received an allograft and an anterior cervical plate. Wear results: cervical spine simulators that applied the loads and motions associated with activities of daily living produced wear particulate at a rate of 1.2 mg per million cycles. Device height decreased 0.02 mm per million cycles with approximately 77% of this decrease due to gradual creep of the nucleus under the constant compressive load. Particles generated were granular in shape with a mean feret diameter of 3.9 μm. All animals tolerated placement of the Bryan disc. Wear debris was present in the periprosthetic and epidural spaces in some animals. However, no significant inflammatory response was observed. No wear material was found distant from the implant in draining lymph tissue, the liver, or the spleen. The Bryan disc has satisfactory wear characteristics and does not produce a significant inflammatory response.