WMWilliam D. Middleton

William D. Middleton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


William D. Middleton has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ultrasound-guided Chest Biopsies

    by William D. Middleton, Sharlene A. Teefey, Nirvikar Dahiya

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.


  • Development of Nonobstructive Intraarterial Thrombi After Injection of Thrombin into Pseudoaneurysms

    by Anil K. Dasyam, William D. Middleton, Sharlene A. Teefey

    OBJECTIVE. Our objective was to describe the development of nonobstructive, localized intraarterial thrombi after percutaneous injection of thrombin into femoral pseudoaneurysms. CONCLUSION. Partial extension of thrombi into the arterial lumen may occur after injection of thrombin into small pseudoaneurysms with short necks. In our experience, this is an asymptomatic and self-limited complication of the procedure.


    • 1 April 2004
      • Vol. 86  (4) , 708-16

    Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases.

    by Sharlene A Teefey, David A Rubin, William D Middleton, Charles F Hildebolt, Robert A Leibold, Ken Yamaguchi

    Although many investigators have evaluated the accuracy of ultrasonography and magnetic resonance imaging for the detection of full and partial-thickness rotator cuff tears, few have directly compared the two tests. The purpose of our study was to compare the accuracy of the two tests for detection and measurement of the size of rotator cuff tears, with arthroscopic findings used as the standard. One hundred and twenty-four consecutive patients with shoulder pain were prospectively studied with ultrasonography and magnetic resonance imaging. Seventy-one had subsequent arthroscopy, and they formed the study group. The arthroscopic diagnosis was a full-thickness tear in forty-six patients, a partial-thickness tear in nineteen, and no tear in six. The presence or absence of a full or partial-thickness tear and the tear size as demonstrated by each imaging test and at the time of arthroscopy were recorded. The findings of the imaging tests and arthroscopy were then compared for each parameter. Ultrasonography correctly identified forty-five of the forty-six full-thickness tears and magnetic resonance imaging, all forty-six. Ultrasonography correctly identified thirteen of the nineteen partial-thickness rotator cuff tears and magnetic resonance imaging, twelve of the nineteen. The overall accuracy for both imaging tests was 87%. Ultrasonography correctly predicted the degree of retraction of 73% of the full-thickness tears and the length of 85% of the partial-thickness tears, and magnetic resonance imaging correctly predicted the retraction and length of 63% and 75%, respectively. Ultrasonography correctly predicted the width of 87% of the full-thickness tears and 54% of the partial-thickness tears, and magnetic resonance imaging correctly predicted the width of 80% and 75%, respectively. No significant differences between ultrasonography and magnetic resonance imaging were demonstrated (p > 0.05). Ultrasonography and magnetic resonance imaging had comparable accuracy for identifying and measuring the size of full-thickness and partial-thickness rotator cuff tears. When an investigator has comparable experience with both imaging tests, the decision regarding which test to perform for rotator cuff assessment does not need to be based on accuracy concerns. The choice can be based on other factors, such as the importance of ancillary clinical information (regarding lesions of the glenoid labrum, joint capsule, or surrounding muscle or bone), the presence of an implanted device, patient tolerance, and cost.


  • An Overview of Ultrasonography of the Shoulder

    by Christine O. M.D. Menias, William D. M.D. Middleton, Sharlene A. M.D. Teefey

    Summary: Because of its low-cost, easy accessibility, and great flexibility, ultrasonography was introduced as an alternative noninvasive means for detection of shoulder pathology, in particular, for detection of rotator cuff abnormalities. This review concentrates on the relevant musculoskeletal anatomy, examination technique, normal sonographic anatomy, and the sonographic findings of rotator cuff tears and biceps tendon pathology.