RJRahula Janiš

Rahula Janiš

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rahula Janiš has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • A. Zapletalova

    Department of Fat, Surfactant and Cosmetics Technology, Tomas Bata University in Zlin, Zlin, Czech Republic

    1 shared publication
  • Andrea Zapletalová

    Department of Fat, Surfactant and Cosmetics Technology, Tomas Bata University in Zlín, Vavrečkova 275, 76272 Zlin, Czech Republic

    1 shared publication
  • Antonín Klásek

    Department of Chemistry, Faculty of Technology, Tomas Bata University, CZ-762 72 Zlín

    1 shared publication
  • Jana Bobálová

    Faculty of Technology Tomas Bata University in Zlin Nám. TGM‐275, CZ‐762 72 Zlín, Czech Republic

    1 shared publication
  • Jana Pavlačková

    Department of Lipids, Detergents and Cosmetics Technology, Faculty of Technology, Tomas Bata University in Zlín, Vavrečkova 5669, 760 01 Zlín, Czech Republic

    1 shared publication
  • K. Kejlova

    National Institute of Public Health, Centre of Toxicology and Health Safety, Prague, Czech Republic

    1 shared publication

Latest Publications

  • Comparison of metrological techniques for evaluation of the impact of a cosmetic product containing hyaluronic acid on the properties of skin surface

    by Rahula Janiš, Vladimír Pata, Pavlína Egner, Jana Pavlačková, Andrea Zapletalová, Kristina Kejlová

    The aim of this research was to evaluate mutual interchangeability of four principally different biometric instrumental techniques designed for objective measurement of changes in the physical, mechanical, and topographical properties of the skin surface treated with commercial antiaging cosmetic products with hyaluronic acid. The following instrumental devices were used: Visioscope PC 35, Corneometer Multiprobe Adapter MPA 6, Reviscometer RVM 600, and 3D scanner Talysurf CLI 500. The comparison of the individual methods was performed using cluster analysis. The study involved 25 female volunteers aged 40–65. Measurements were taken before and after 30 daily in vivo applications of an antiaging preparation to the skin surface in the periorbital area. A slight reduction in skin surface roughness was recorded in 55% of the volunteers. On the contrary, a worsening from their initial states was detected in 25% of the subjects, while for 20%, no significant change was reported. Cluster analysis confirmed that the mentioned methodologies can be divided into two basic clusters, namely, a cluster of methods recording the changes in skin relief by means of optical techniques, and a cluster of methods investigating changes in hydration and anisotropy. In practice, the techniques in different clusters are not interchangeable and should be assessed separately.


  • Objective measurements of skin surface roughness after microdermabrasion treatment

    by A. Zapletalova, V. Pata, R. Janis, K. Kejlova, P. Stoklasek

    Background: The aim of this article is to present a new methodology for assessment of skin topology using a three‐dimensional image (3D).Methods: The measurement of the skin surface roughness is based on 3D scanning of silicone replicas by chromatic aberration length technique in a contactless manner, i.e. by a polychromatic light beam. Analysis of the skin surface reprints was performed using Talymap, Gold version. Results were analysed by fractal geometry, which allows to evaluate changes of the skin surface before and after application of cosmetics and instrumental cosmetological techniques. The methodology was applied for objective assessment of the effects of diamond microdermabrasion on the skin surface roughness. Measurements were performed on 23 volunteers in the age group of 31–67 years.Results: Based on the results of skin surface scanning after the treatment with diamond microdermabrasion it may be concluded that inequalities of the skin surface are reduced immediately after exfoliation. However, this effect mostly diminishes within 14 days after treatment. The entire study ultimately suggests that the instrumental method used only leads to improvement of the skin surface immediately after its application. Thermo vision images of the skin surface temperature were obtained during the application of the abrasive method. The experimental results showed that the skin is rather cooled than heated by the treatment.Conclusion: This study is focused on the development of a methodology for objective measurement of changes in treated skin relief using 3D scanning. The results are evaluated using fractal dimension. The output may also include also an enlarged model of the skin surface made by 3D printer, which can serve for illustrative communication with the client.