NPNick Pfeiffer

Nick Pfeiffer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nick Pfeiffer has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Successive order, multiple scattering of two-term Henyey-Greenstein phase functions

    by Nick Pfeiffer, Glenn H. Chapman

    An analytic solution to the problem of determining photon direction after successive scatterings in an infinite, homogeneous, isotropic medium, where each scattering event is in accordance with a two-term Henyey-Greenstein phase function, is presented and compared against Monte Carlo simulation results. The photon direction is described by a probability density function of the dot product of the initial direction and the direction after multiple scattering events, and it is found that such a probability density function can be represented as a weighted series of one-term Henyey-Greenstein phase functions.


  • Enhanced angular domain optical imaging by background scattered light subtraction from a deviated laser source

    by Fartash Vasefi, Glenn H. Chapman, Paulman Chan, Bozena Kaminska, Nick Pfeiffer

    Imaging structures within a turbid medium using Angular Domain Imaging (ADI) employs angular filter array aligned to a laser source to separate ballistic and quasi-ballistic photons from the highly scattered light by means of angular filtration. The angular filter consists of a high aspect ratio linear array of silicon micromachined tunnels, 51 micron wide by 10mm long with a 0.29 degree acceptance angle. At heavy scattering ratios of >1E7 image detectability declines due to the non-uniform scattered background light fraction still within the acceptance angle. This scattered signal can be separated out by introducing a wedge prism to deviate the laser source where it enters the medium by an angle slightly larger than the acceptance angle. This creates a second image consisting of pure scattering photons with the filtration characteristics of the angular filter, and a pixel by pixel correspondence to the fully scattered illumination emitted from the medium. Experiments used an 808 nm laser diode, collimated to an 8×1 mm line of light, entering a 5cm thick medium with a scattering ratio of > 1E6, with a wedge prism creating a 0.44 degree deviation. Digitally subtracting the deviated scattered signal from the original image significantly reduced the scattered background and enhanced image contrast. We can have about images at least 40 times more of our previous scattering limits. Depending on test phantom object location, the contrast level can be increased from 4% of the total dynamic range to over 50% which results in higher definition and visibility of our micro-scale test structures in the turbid medium.


  • Angular domain imaging of phantom objects within highly scattering mediums

    by Nick Pfeiffer, Bob Wai, Glenn H. Chapman

    Most optical tomography work within highly scattering media has employed coherence domain and time domain methodologies, both detecting the shortest path photons over the dominant randomly scattered background. Angular domain imaging instead uses micromachined collimators to observe only those photons within a small angle of the aligned laser light source, which simulations show are the shortest path photons, while rejecting heavily scattered light. These angular filters consist of micromachined silicon collimator channels 51 micron wide by 10 mm or 20 mm long on 102 micron spacing giving acceptance angles of 0.29 to 0.15 degrees on a CCD detector. Phantom test objects were observed in mediums ranging from 1 to 5 cm thick at scattered to ballistic ratios of 500,000:1 to 10,000,000:1 depending on the illumination pattern. Object detection was retained at the same scattering levels for either 1 cm or 5cm thick mediums, demonstrating little dependence on medium thickness. Detection was also independent of the object size: phantoms ranging from thin structures of 100 micron wide lines and spaces to 4 mm spheres were detected at approximately the same scattering ratios. Minimum size resolution depends on CCD pixel size, not the collimator characteristics. Furthermore, detection was a function of the scattering ratio produced after the phantom's position, not of the whole medium’s scattering ratio. This means objects nearer the detector are much more observable. Longer collimators significantly increase the scattered light rejection. Monte-Carlo simulations with angular tracking demonstrate the object size independence and are undertaken to verify the other behaviors.