Denis Jordan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Denis Jordan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Eberhard F. Kochs
Klinik für Anaesthesiologie, Technische Universität München, Klinikum rechts der Isar, Ismaninger Str. 22, 81675, München, Germany
2 shared publications- Gerhard Schneider
Department of Anesthesiology and Intensive Care, School of Medicine and Health, Technical University of Munich, Munich, Germany
2 shared publications Alexander Kretschmer
Klinik für Anaesthesiologie, Technische Universität München, Klinikum rechts der Isar, Ismaninger Str. 22, 81675, München, Germany
1 shared publicationAndreas Hock
1 shared publicationChristopher Kramer
Klinik für Anaesthesiologie, Technische Universität München, Klinikum rechts der Isar, Ismaninger Str. 22, 81675, München, Germany
1 shared publication- Eberhard F. Kochs
Klinik für Anaesthesiologie, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 22 December 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (12) , e115754
Electromyographic Permutation Entropy Quantifies Diaphragmatic Denervation and Reinnervation
Spontaneous reinnervation after diaphragmatic paralysis due to trauma, surgery, tumors and spinal cord injuries is frequently observed. A possible explanation could be collateral reinnervation, since the diaphragm is commonly double-innervated by the (accessory) phrenic nerve. Permutation entropy (PeEn), a complexity measure for time series, may reflect a functional state of neuromuscular transmission by quantifying the complexity of interactions across neural and muscular networks. In an established rat model, electromyographic signals of the diaphragm after phrenicotomy were analyzed using PeEn quantifying denervation and reinnervation. Thirty-three anesthetized rats were unilaterally phrenicotomized. After 1, 3, 9, 27 and 81 days, diaphragmatic electromyographic PeEn was analyzed in vivo from sternal, mid-costal and crural areas of both hemidiaphragms. After euthanasia of the animals, both hemidiaphragms were dissected for fiber type evaluation. The electromyographic incidence of an accessory phrenic nerve was 76%. At day 1 after phrenicotomy, PeEn (normalized values) was significantly diminished in the sternal (median: 0.69; interquartile range: 0.66–0.75) and mid-costal area (0.68; 0.66–0.72) compared to the non-denervated side (0.84; 0.78–0.90) at threshold p<0.05. In the crural area, innervated by the accessory phrenic nerve, PeEn remained unchanged (0.79; 0.72–0.86). During reinnervation over 81 days, PeEn normalized in the mid-costal area (0.84; 0.77–0.86), whereas it remained reduced in the sternal area (0.77; 0.70–0.81). Fiber type grouping, a histological sign for reinnervation, was found in the mid-costal area in 20% after 27 days and in 80% after 81 days. Collateral reinnervation can restore diaphragm activity after phrenicotomy. Electromyographic PeEn represents a new, distinctive assessment characterizing intramuscular function following denervation and reinnervation.
- 22 December 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (12) , e115754
Open AccessElectromyographic Permutation Entropy Quantifies Diaphragmatic Denervation and Reinnervation
Spontaneous reinnervation after diaphragmatic paralysis due to trauma, surgery, tumors and spinal cord injuries is frequently observed. A possible explanation could be collateral reinnervation, since the diaphragm is commonly double-innervated by the (accessory) phrenic nerve. Permutation entropy (PeEn), a complexity measure for time series, may reflect a functional state of neuromuscular transmission by quantifying the complexity of interactions across neural and muscular networks. In an established rat model, electromyographic signals of the diaphragm after phrenicotomy were analyzed using PeEn quantifying denervation and reinnervation. Thirty-three anesthetized rats were unilaterally phrenicotomized. After 1, 3, 9, 27 and 81 days, diaphragmatic electromyographic PeEn was analyzed in vivo from sternal, mid-costal and crural areas of both hemidiaphragms. After euthanasia of the animals, both hemidiaphragms were dissected for fiber type evaluation. The electromyographic incidence of an accessory phrenic nerve was 76%. At day 1 after phrenicotomy, PeEn (normalized values) was significantly diminished in the sternal (median: 0.69; interquartile range: 0.66–0.75) and mid-costal area (0.68; 0.66–0.72) compared to the non-denervated side (0.84; 0.78–0.90) at threshold p<0.05. In the crural area, innervated by the accessory phrenic nerve, PeEn remained unchanged (0.79; 0.72–0.86). During reinnervation over 81 days, PeEn normalized in the mid-costal area (0.84; 0.77–0.86), whereas it remained reduced in the sternal area (0.77; 0.70–0.81). Fiber type grouping, a histological sign for reinnervation, was found in the mid-costal area in 20% after 27 days and in 80% after 81 days. Collateral reinnervation can restore diaphragm activity after phrenicotomy. Electromyographic PeEn represents a new, distinctive assessment characterizing intramuscular function following denervation and reinnervation.
- 18 January 2014
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (6) , 573-580
Non-stationarity of EEG during wakefulness and anaesthesia: advantages of EEG permutation entropy monitoring
Monitors evaluating the electroencephalogram (EEG) to determine depth of anaesthesia use spectral analysis approaches for analysis windows up to 61.5 s as well as additional smoothing algorithms. Stationary EEG is required to reliably apply the index algorithms. Because of rapid physiological changes, artefacts, etc., the EEG may not always fulfil this requirement. EEG analysis using permutation entropy (PeEn) may overcome this issue, since PeEn can also be applied to practically nonstationary EEG. One objective was to determine the duration of EEG sequences that can be considered stationary at different anaesthetic levels. The second, more important objective was to test the reliability of PeEn to reflect the anaesthetic levels for short EEG segments. EEG was recorded from 15 volunteers undergoing sevoflurane and propofol anaesthesia at different anaesthetic levels and for each group 10 data sets were included. EEG stationarity was evaluated for EEG sample lengths from 4 to 116 s for each level. PeEn was calculated for these sequences using different parameter settings and analysis windows from 2 to 60 s. During wakefulness EEG can only be considered stationary for sequences up to 12 s. With increasing anaesthetic level the probability and duration of stationary EEG increases. PeEn is able to reliably separate consciousness from unconsciousness for EEG segments as short as 2 s. Especially during wakefulness a conflict between stationary EEG sequence durations and methods used for monitoring may exist. PeEn does not require stationarity and functions for EEG sequences as short as 2 s. These promising results seem to support the application of non-linear parameters, such as PeEn, to depth of anaesthesia monitoring.
- 18 January 2014
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (6) , 573-580
Non-stationarity of EEG during wakefulness and anaesthesia: advantages of EEG permutation entropy monitoring
Monitors evaluating the electroencephalogram (EEG) to determine depth of anaesthesia use spectral analysis approaches for analysis windows up to 61.5 s as well as additional smoothing algorithms. Stationary EEG is required to reliably apply the index algorithms. Because of rapid physiological changes, artefacts, etc., the EEG may not always fulfil this requirement. EEG analysis using permutation entropy (PeEn) may overcome this issue, since PeEn can also be applied to practically nonstationary EEG. One objective was to determine the duration of EEG sequences that can be considered stationary at different anaesthetic levels. The second, more important objective was to test the reliability of PeEn to reflect the anaesthetic levels for short EEG segments. EEG was recorded from 15 volunteers undergoing sevoflurane and propofol anaesthesia at different anaesthetic levels and for each group 10 data sets were included. EEG stationarity was evaluated for EEG sample lengths from 4 to 116 s for each level. PeEn was calculated for these sequences using different parameter settings and analysis windows from 2 to 60 s. During wakefulness EEG can only be considered stationary for sequences up to 12 s. With increasing anaesthetic level the probability and duration of stationary EEG increases. PeEn is able to reliably separate consciousness from unconsciousness for EEG segments as short as 2 s. Especially during wakefulness a conflict between stationary EEG sequence durations and methods used for monitoring may exist. PeEn does not require stationarity and functions for EEG sequences as short as 2 s. These promising results seem to support the application of non-linear parameters, such as PeEn, to depth of anaesthesia monitoring.
- 1 July 2006
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 51 (2) , 89-94
EEG parameters and their combination as indicators of depth of anaesthesia / EEG-Parameter und deren Kombination für das Narkosemonitoring
EEG parameters for assessment of depth of anaesthesia are typically based on different signal processing methods, such as spectral and complexity analysis. In the present study, the parameters investigated (WSMF, qWSMF, approximate entropy and Lempel-Ziv complexity) do not correlate monotonically to depth of anaesthesia. To obtain this correlation, parameters are combined based on fuzzy inference, whereby each parameter only operates in a specific range. Fuzzy inference seems to be a suitable approach, as the indicator designed separates wakefulness from unconsciousness as well as the best single parameter does and correlates to the depth of anaesthesia.
- 1 July 2006
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 51 (2) , 89-94
EEG parameters and their combination as indicators of depth of anaesthesia / EEG-Parameter und deren Kombination für das Narkosemonitoring
EEG parameters for assessment of depth of anaesthesia are typically based on different signal processing methods, such as spectral and complexity analysis. In the present study, the parameters investigated (WSMF, qWSMF, approximate entropy and Lempel-Ziv complexity) do not correlate monotonically to depth of anaesthesia. To obtain this correlation, parameters are combined based on fuzzy inference, whereby each parameter only operates in a specific range. Fuzzy inference seems to be a suitable approach, as the indicator designed separates wakefulness from unconsciousness as well as the best single parameter does and correlates to the depth of anaesthesia.