Chai H. Yoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chai H. Yoo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Kyungsik Kim
GS Engineering and Construction, Yeoksam-Dong, Gangnam-Gu, Seoul 135-985, Korea
4 shared publicationsSung C. Lee
3 shared publications- Sung C. Lee
Professor, Dept. of Civil and Environmental Engineering, Dongguk Univ., Seoul 100-715, Korea
3 shared publications Byung H. Choi
Post-Doctoral Researcher, Dept. of Civil Engineering, Auburn Univ., Auburn, AL 36849-5337
2 shared publications- Doo S. Lee
Professor, Dept. of Civil and Environmental Engineering, Dongguk Univ., Seoul 100-715, Korea
2 shared publications Frazier Parker
Department of Civil Engineering, Auburn University, Auburn, AL 36849-5337, U.S.A.
2 shared publications
Latest Publications
- 1 January 2011
- Published by Elsevier
- p. 155-198
Beam-Columns
- 1 January 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (1) , 3-10
Further Insights into Postbuckling of Web Panels. I: Review of Flange Anchoring Mechanism
This study revisits the anchoring mechanism believed to be the source of the postbuckling strength of plate girder web panels. In classical tension field theories, it has been implicitly assumed that a tension field cannot develop in the web panel without recourse to the anchoring mechanism of the flanges and/or adjacent panels. The contribution of the flange anchoring mechanism in practical plate girders differs from theory to theory. It has been found during this study that the anchoring mechanism hardly develops, no matter how heavy the flanges are, without transverse stiffeners that have sufficient axial stiffness necessary to keep the flanges from moving the web panel inwards during the anchoring action. In practical plate girders, the contribution of the flange anchoring mechanism to the postbuckling strength is negligibly small not because the flanges are too flexible to function as anchors but because the transverse stiffeners are axially too flexible to support the flanges. Taking advantage of the flange anchoring mechanism in practical designs is beyond the realm of possibility because it requires an inconceivably high axial stiffness of the transverse stiffeners.
- 1 January 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (1) , 3-10
Further Insights into Postbuckling of Web Panels. I: Review of Flange Anchoring Mechanism
This study revisits the anchoring mechanism believed to be the source of the postbuckling strength of plate girder web panels. In classical tension field theories, it has been implicitly assumed that a tension field cannot develop in the web panel without recourse to the anchoring mechanism of the flanges and/or adjacent panels. The contribution of the flange anchoring mechanism in practical plate girders differs from theory to theory. It has been found during this study that the anchoring mechanism hardly develops, no matter how heavy the flanges are, without transverse stiffeners that have sufficient axial stiffness necessary to keep the flanges from moving the web panel inwards during the anchoring action. In practical plate girders, the contribution of the flange anchoring mechanism to the postbuckling strength is negligibly small not because the flanges are too flexible to function as anchors but because the transverse stiffeners are axially too flexible to support the flanges. Taking advantage of the flange anchoring mechanism in practical designs is beyond the realm of possibility because it requires an inconceivably high axial stiffness of the transverse stiffeners.
- 1 January 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (1) , 11-18
Further Insights into Postbuckling of Web Panels. II: Experiments and Verification of New Theory
This study brings light to the source of plastic hinge-like failure modes often observed in tests. It is found that such failure modes, accompanied by severe flange deformations, are not due to the anchoring action of the flanges, but are due to direct shear force acting on the flange cross sections. This study also examines why the horizontal anchoring mechanism cannot develop in interior panels or in end panels with a heavy end stiffener. The results obtained in this study, along with the findings reported in the companion paper (Part I), reveal that the anchoring mechanism is virtually nonexistent in normal plate girders. That is to say, the postbuckling strength of the web panel in normal plate girders is mostly attributable to the postbuckling mechanism developed by means of lateral supports provided by the flanges and the transverse stiffeners. It is also found that a tension field can develop in the end panel and it is recommended, therefore, that any restriction contrary to this observation found in current design codes be repealed.
- 1 January 2009
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 135 (1) , 11-18
Further Insights into Postbuckling of Web Panels. II: Experiments and Verification of New Theory
This study brings light to the source of plastic hinge-like failure modes often observed in tests. It is found that such failure modes, accompanied by severe flange deformations, are not due to the anchoring action of the flanges, but are due to direct shear force acting on the flange cross sections. This study also examines why the horizontal anchoring mechanism cannot develop in interior panels or in end panels with a heavy end stiffener. The results obtained in this study, along with the findings reported in the companion paper (Part I), reveal that the anchoring mechanism is virtually nonexistent in normal plate girders. That is to say, the postbuckling strength of the web panel in normal plate girders is mostly attributable to the postbuckling mechanism developed by means of lateral supports provided by the flanges and the transverse stiffeners. It is also found that a tension field can develop in the end panel and it is recommended, therefore, that any restriction contrary to this observation found in current design codes be repealed.
- 16 May 2007
- Published by Wiley in International Journal for Numerical and Analytical Methods in Geomechanics
- Vol. 32 (3) , 289-306
Effects of frictional forces acting on sidewalls of buried box culverts
The effects of frictional forces acting on the sidewalls of buried box culverts are presented as determined with finite element method (FEM) and detailed soil modelling. The possibility of reducing earth pressure on deeply buried concrete box culverts by the imperfect trench installation (ITI) method has been contemplated during the last several decades. There have been limited research results published primarily regarding the qualitative aspect of load reduction in ITIs. It was found during the course of this study that significant frictional forces develop along the sidewalls of box culverts and adjacent sidefills in ITIs. Current American Association of State Highway and Transportation Officials provisions do not consider these frictional forces, but they cannot be neglected in ITIs, as their effect is dominant. An optimum geometry for the soft zone in ITIs is presented to maximize earth load reductions. The soil–structure interaction at the box culvert–soil interface was found to have a significant effect on total earth pressure acting on the bottom slab. Predictor equations for earth load reduction rates were formulated for ITIs incorporating the optimum soft zone geometry based on the FEM. Copyright © 2007 John Wiley & Sons, Ltd.
- 16 May 2007
- Published by Wiley in International Journal for Numerical and Analytical Methods in Geomechanics
- Vol. 32 (3) , 289-306
Effects of frictional forces acting on sidewalls of buried box culverts
The effects of frictional forces acting on the sidewalls of buried box culverts are presented as determined with finite element method (FEM) and detailed soil modelling. The possibility of reducing earth pressure on deeply buried concrete box culverts by the imperfect trench installation (ITI) method has been contemplated during the last several decades. There have been limited research results published primarily regarding the qualitative aspect of load reduction in ITIs. It was found during the course of this study that significant frictional forces develop along the sidewalls of box culverts and adjacent sidefills in ITIs. Current American Association of State Highway and Transportation Officials provisions do not consider these frictional forces, but they cannot be neglected in ITIs, as their effect is dominant. An optimum geometry for the soft zone in ITIs is presented to maximize earth load reductions. The soil–structure interaction at the box culvert–soil interface was found to have a significant effect on total earth pressure acting on the bottom slab. Predictor equations for earth load reduction rates were formulated for ITIs incorporating the optimum soft zone geometry based on the FEM. Copyright © 2007 John Wiley & Sons, Ltd.
- 1 March 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 133 (3) , 277-285
Soil-Structure Interaction and Imperfect Trench Installations for Deeply Buried Concrete Pipes
The imperfect trench installation method is used to reduce earth pressure on buried concrete pipes. Few quantitative refinements to the imperfect trench installation method, however, have been added since the fundamental mechanics of the reverse arching action were proposed by Marston and Spangler. There have been limited research results published regarding, primarily, qualitative aspects of earth load reduction for imperfect trench conditions. This paper identifies variables that significantly affect earth loads, as well as the effects of bedding and sidefill treatments. An optimum geometry for imperfect trench installations with regard to a soft material zone is presented to maximize the earth load reduction effects. The optimization process was based on parametric studies of the geometry and location of the soft zone, bedding, and sidefill treatments to reduce earth pressures. Predictor equations for earth load reduction rates were formulated incorporating the optimum geometry for the soft zone and be...
- 1 March 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Geotechnical and Geoenvironmental Engineering
- Vol. 133 (3) , 277-285
Soil-Structure Interaction and Imperfect Trench Installations for Deeply Buried Concrete Pipes
The imperfect trench installation method is used to reduce earth pressure on buried concrete pipes. Few quantitative refinements to the imperfect trench installation method, however, have been added since the fundamental mechanics of the reverse arching action were proposed by Marston and Spangler. There have been limited research results published regarding, primarily, qualitative aspects of earth load reduction for imperfect trench conditions. This paper identifies variables that significantly affect earth loads, as well as the effects of bedding and sidefill treatments. An optimum geometry for imperfect trench installations with regard to a soft material zone is presented to maximize the earth load reduction effects. The optimization process was based on parametric studies of the geometry and location of the soft zone, bedding, and sidefill treatments to reduce earth pressures. Predictor equations for earth load reduction rates were formulated incorporating the optimum geometry for the soft zone and be...
- 1 October 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (10) , 1611-1620
Interaction of Top Lateral and Internal Bracing Systems in Tub Girders
A lateral bracing system is installed at the top flange level of a steel tub girder to form a quasi-closed box, thereby increasing torsional resistance and retaining the original box shape. A single diagonal (SD) type or crossed diagonal type is typically adopted along with intermediate internal bracing systems (also called internal cross frames) that are placed at either even or odd numbered spacing. A significant coupling action between SD bracing members and internal cross-frame members has been found to occur in the case of a SD lateral bracing system and internal cross frames placed at odd numbered panel spacing. The member forces developed in lateral bracing are 25–30% higher than those in structures with internal cross frames installed at even numbered panel spacing. Matrix equations were formulated to compute the brace forces developed in both SD lateral bracing and K-shaped internal cross-frame members subjected to bending action. Member forces computed from the new equations were compared with t...
- 1 October 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (10) , 1611-1620
Interaction of Top Lateral and Internal Bracing Systems in Tub Girders
A lateral bracing system is installed at the top flange level of a steel tub girder to form a quasi-closed box, thereby increasing torsional resistance and retaining the original box shape. A single diagonal (SD) type or crossed diagonal type is typically adopted along with intermediate internal bracing systems (also called internal cross frames) that are placed at either even or odd numbered spacing. A significant coupling action between SD bracing members and internal cross-frame members has been found to occur in the case of a SD lateral bracing system and internal cross frames placed at odd numbered panel spacing. The member forces developed in lateral bracing are 25–30% higher than those in structures with internal cross frames installed at even numbered panel spacing. Matrix equations were formulated to compute the brace forces developed in both SD lateral bracing and K-shaped internal cross-frame members subjected to bending action. Member forces computed from the new equations were compared with t...
- 1 October 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (10) , 1580-1589
Mechanics of Web Panel Postbuckling Behavior in Shear
This paper revisits a fundamental assumption used in most classical failure theories for postbuckled web plates under shear, namely that the compressive stresses that develop in the direction perpendicular to the tension diagonal do not increase any further once elastic buckling has taken place. This assumption naturally led to a well-known theory that tension field action in plate girders with transverse stiffeners must be anchored by flanges and stiffeners in order for the webs to develop their full postbuckling strength. However, a careful examination of the results of the nonlinear finite-element analyses carried out for this study reveals that the diagonal compression continuously increases in close proximity to the edges after buckling, thereby producing in the web panel a self-equilibrating force system that does not depend on the flanges and stiffeners. These findings provide a fuller understanding of the actual mechanics of tension field action.
- 1 October 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (10) , 1580-1589
Mechanics of Web Panel Postbuckling Behavior in Shear
This paper revisits a fundamental assumption used in most classical failure theories for postbuckled web plates under shear, namely that the compressive stresses that develop in the direction perpendicular to the tension diagonal do not increase any further once elastic buckling has taken place. This assumption naturally led to a well-known theory that tension field action in plate girders with transverse stiffeners must be anchored by flanges and stiffeners in order for the webs to develop their full postbuckling strength. However, a careful examination of the results of the nonlinear finite-element analyses carried out for this study reveals that the diagonal compression continuously increases in close proximity to the edges after buckling, thereby producing in the web panel a self-equilibrating force system that does not depend on the flanges and stiffeners. These findings provide a fuller understanding of the actual mechanics of tension field action.
- 1 October 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (5) , 707-718
Ultimate Strength Interaction of Bending and Torsion of Steel/Concrete Composite Trapezoidal Box Girders in Positive Bending
In the case of horizontally curved highway bridges, girders are subjected to the combined action of vertical bending and torsion due to the offset. Although steel/concrete composite sections are proportioned to avoid abrupt brittle failure, the ultimate strengths of composite box girders subjected to bending and torsion may be limited by the diagonal tensile stress in the deck concrete induced by the St. Venant torsion. Concurrent compressive stresses in the concrete deck improve the shear resisting capacity of concrete, thereby resulting in increased torsional resistance of the composite box girder in positive bending. Three-dimensional finite element analyses and classical strength of materials investigations were conducted in this study to determine the ultimate strengths of composite box girders in bending and torsion and their interaction. An advanced material model including the concrete tension mechanism was incorporated in the incremental nonlinear analyses. The ultimate strengths from numerical data were compared with theoretically derived values. The proposed interaction equation is very simple, yet it provides a rational lower bound for the determination of the ultimate strengths of concrete/steel composite box girders.
- 1 October 2006
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 9 (5) , 707-718
Ultimate Strength Interaction of Bending and Torsion of Steel/Concrete Composite Trapezoidal Box Girders in Positive Bending
In the case of horizontally curved highway bridges, girders are subjected to the combined action of vertical bending and torsion due to the offset. Although steel/concrete composite sections are proportioned to avoid abrupt brittle failure, the ultimate strengths of composite box girders subjected to bending and torsion may be limited by the diagonal tensile stress in the deck concrete induced by the St. Venant torsion. Concurrent compressive stresses in the concrete deck improve the shear resisting capacity of concrete, thereby resulting in increased torsional resistance of the composite box girder in positive bending. Three-dimensional finite element analyses and classical strength of materials investigations were conducted in this study to determine the ultimate strengths of composite box girders in bending and torsion and their interaction. An advanced material model including the concrete tension mechanism was incorporated in the incremental nonlinear analyses. The ultimate strengths from numerical data were compared with theoretically derived values. The proposed interaction equation is very simple, yet it provides a rational lower bound for the determination of the ultimate strengths of concrete/steel composite box girders.
- 1 August 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (8) , 1212-1222
Brace Forces in Steel Box Girders with Single Diagonal Lateral Bracing Systems
Trapezoidal steel box girders (also known as tub girders) may be at their critical stage during construction because the noncomposite steel section must support both the wet concrete and the entire construction load. A lateral bracing system is usually installed at the top flange level to form a quasi-closed box, thereby increasing the torsional stiffness during construction. Typical lateral bracing includes a single-diagonal type (SD type) and a crossed-diagonal type (XD type). The brace forces in box girders with XD type lateral bracing systems can now be estimated with good accuracy. In some horizontally curved box girders with SD-type systems, substantial axial forces, possibly up to 35% of the total force, are developed in struts due to induced torsion and distortion, which are neglected in previous studies. In this study, analytical equations were formulated to compute the brace forces developed in bracing members by taking into account bending and torsional actions of tub girders with SD-type later...
- 1 August 2006
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 132 (8) , 1212-1222
Brace Forces in Steel Box Girders with Single Diagonal Lateral Bracing Systems
Trapezoidal steel box girders (also known as tub girders) may be at their critical stage during construction because the noncomposite steel section must support both the wet concrete and the entire construction load. A lateral bracing system is usually installed at the top flange level to form a quasi-closed box, thereby increasing the torsional stiffness during construction. Typical lateral bracing includes a single-diagonal type (SD type) and a crossed-diagonal type (XD type). The brace forces in box girders with XD type lateral bracing systems can now be estimated with good accuracy. In some horizontally curved box girders with SD-type systems, substantial axial forces, possibly up to 35% of the total force, are developed in struts due to induced torsion and distortion, which are neglected in previous studies. In this study, analytical equations were formulated to compute the brace forces developed in bracing members by taking into account bending and torsional actions of tub girders with SD-type later...