GCG. Cacho

G. Cacho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


G. Cacho has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy

    by G. Cacho, J. L. Pérez-Calle, A. Barbado, J. L. Lledó, R. Ojea, C. M. Fernández-Rodríguez

    Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide. We aimed at prospectively examining the advantages of capnography over the standard pulse oximetry monitoring during sedated colonoscopies. Fifty patients undergoing colonoscopy were simultaneously monitored with pulse oximetry and capnography by using two different devices in each patient. Several sedation regimens were administered. Episodes of apnea or hypoventilation detected by capnography were compared with the occurrence of hypoxemia. Twenty-nine episodes of disordered respiration occurred in 16 patients (mean duration 54.4 seconds). Only 38% of apnea or hypoventilation episodes were detected by pulse oximetry. A mean delay of 38.6 seconds was observed in the events detected by pulse oximetry (two episodes of disturbed ventilation were simultaneously detected by capnography and pulse oximetry). Apnea or hypoventilation commonly occurs during colonoscopy with sedation. Capnography is more reliable than pulse oximetry in early detection of respiratory depression in this setting.


  • Open Access

    Diagnostic yield of brush cytology for biliary stenosis during ERCP

    by R. Temiño López-Jurado, G. Cacho Acosta, M. Argüelles Pintos, G. Rodríguez Caravaca, J. L. Lledó Navarro, C. Fernández Rodríguez

    To evaluate the diagnostic yield of brush cytology for biliary strictures detected on ERCP when a systematic approach is used. Data on 62 consecutive patients with a biliary stricture on ERCP were collected. Cytological samples were processed immediately after brushing in the endoscopy room, and all were analyzed by the same pathologist. For the statistical analysis specimens were classified as positive, negative, suspicious for malignancy (presence of atypias), and unsatisfactory for evaluation. Final diagnosis was based on either histopathologic (surgery or biopsies by other techniques) or clinical/radiographic diagnosis. A total of 71 cytological specimens were included. Definite diagnosis was malignancy in 49 samples, and benign stricture in 22. Three samples were excluded because of insufficient material or processing artifacts. The sensitivity of biliary brushing was 62% (95% CI 0.47-0.77), specificity was 100%, positive predictive value was 100%, and negative predictive value was 58% (95% CI 0.43-0.75). When suspicious samples were included as malignant, sensitivity was 67% (95% CI 0.54-0.81) without changes in the remaining parameters. Eight patients underwent more than one ERCP. Repeated brush cytology exams in these patients yielded a definitive diagnosis in every case. Brush cytology has intermediate sensitivity with a high specificity. A systematic approach with a dedicated pathologist and the inclusion of significant atypias as malignant results improves sensitivity. Due to its simplicity brush cytology should be performed in all cases of biliary strictures detected on ERCP, and in case of repeated ERCPs additional cytology brushings are recommended.


  • Disturbance of the GH-IGF-I-IGFBPs axis and renal function changes incirrhosis

    by C.M. Fernández-Rodriguez, J.I.R. Prada, M. Moreiras, A. Andrade, R. Aller, J.L. Lledó, J.A. González, G. Cacho, J. Quiroga, J. Prieto

    • 1 November 2000
      • Vol. 23  (9) , 407-11

    [Viability of colonoscopy without analgesia and conscious sedation].

    by G Cacho, C Dueñas, J Pérez De Las Vacas, P Robledo, J L Rosado

    To study the need for analgesia and sedation before colonoscopy. Fifty consecutive outpatients were randomly assigned to receive meperidine (0.7 mg/kg) or midazolam (0-035 mg/kg) intravenously (n = 25) or to receive no medication (n = 25) before colonoscopy. Oxygen saturation (SaO2) and heart rate were monitored. Mean blood pressure (MBP) was recorded before and after endoscopy. Patients in the group receiving no medication who experienced marked abdominal pain received sedation and analgesia similar to the premedicated group. Twenty-four hours after the procedure, the patients evaluated the degree of abdominal pain experienced during colonoscopy on a scale from 0 to 9. Complete colonoscopy was performed in 92% of the patients. No significant changes in heart rate were registered in either group. However, in the premedicated group mean blood pressure fell significantly (97.6 +/- 2.6 vs. 89.5 +/- 2.7 mmHg) before and after colonoscopy, respectively (p < 0.05). Nine patients experienced clinically relevant oxygen desaturation (SaO2 > 90%). Of these, five were from the premedicated group and four were from the group receiving no medication. In two patients, both from the premedicated group, the decrease in SaO2 was severe (SaO2 < 85%). The degree of abdominal pain was similar in both groups: 3.64_0.47 (premedicated) vs. 3.92 +/- 0.5 (non-medicated). In the non-medicated group, two patients required analgesia and sedation to complete the colonoscopy and 20 (80%) preferred not to receive sedation in future colonoscopies. Colonoscopy may be well tolerated without systematic administration of sedation and analgesia, which could be administered selectively.