    Validation of Simplified Renal Dosimetry Protocols for 177Lu-DOTATATE Therapy Using the IDAC-dose Software

    by Anji Yokouchi, Takayuki Shibutani, Takahiro Konishi, Hiroto Yoneyama, Hajime Ichikawa, Hiroshi Wakabayashi

    Validation of Simplified Renal Dosimetry Protocols for 177Lu-DOTATATE Therapy Using the IDAC-dose Software - Molecular Imaging and Radionuclide Therapy


  • Open Access

    Ability of artificial intelligence to diagnose coronary artery stenosis using hybrid images of coronary computed tomography angiography and myocardial perfusion SPECT

    by Hiroto Yoneyama, Kenichi Nakajima, Junichi Taki, Hiroshi Wakabayashi, Shinro Matsuo, Takahiro Konishi, Koichi Okuda, Takayuki Shibutani, Masahisa Onoguchi, Seigo Kinuya

    Detecting culprit coronary arteries in patients with ischemia using only myocardial perfusion single-photon emission computed tomography (SPECT) can be challenging. This study aimed to improve the detection of culprit regions using an artificial neural network (ANN) to analyze hybrid images of coronary computed tomography angiography (CCTA) and myocardial perfusion SPECT. This study enrolled 59 patients with stable coronary artery disease (CAD) who had been assessed by coronary angiography within 60 days of myocardial perfusion SPECT. Two nuclear medicine physicians interpreted the myocardial perfusion SPECT and hybrid images with four grades of confidence, then drew regions on polar maps to identify culprit coronary arteries. The gold standard was determined by the consensus of two other nuclear cardiology specialist based on coronary angiography findings and clinical information. The ability to detect culprit coronary arteries was compared among experienced nuclear cardiologists and the ANN. Receiver operating characteristics (ROC) curves were analyzed and areas under the ROC curves (AUC) were determined. Using hybrid images, observer A detected CAD in the right (RCA), left anterior descending (LAD), and left circumflex (LCX) coronary arteries with 83.6%, 89.3%, and 94.4% accuracy, respectively and observer B did so with 72.9%, 84.2%, and 89.3%, respectively. The ANN was 79.1%, 89.8%, and 89.3% accurate for each coronary artery. Diagnostic accuracy was comparable between the ANN and experienced nuclear medicine physicians. The AUC was significantly improved using hybrid images in the RCA region (observer A: from 0.715 to 0.835, p = 0.0031; observer B: from 0.771 to 0.843, p = 0.042). To detect culprit coronary arteries in perfusion defects of the inferior wall without using hybrid images was problematic because the perfused areas of the LCX and RCA varied among individuals. Hybrid images of CCTA and myocardial perfusion SPECT are useful for detecting culprit coronary arteries. Diagnoses using artificial intelligence are comparable to that by nuclear medicine physicians.


  • Characteristics of iodine-123 IQ-SPECT/CT imaging compared with conventional SPECT/CT

    by Takayuki Shibutani, Masahisa Onoguchi, Hiroto Yoneyama, Takahiro Konishi, Shinro Matsuo, Kenichi Nakajima

    Although the utility of IQ-SPECT imaging using 99mTc and 201Tl myocardial perfusion SPECT has been reported, 123I-labeled myocardial SPECT has not been fully evaluated. We determined the characteristics and utility of 123I IQ-SPECT imaging compared with conventional SPECT (C-SPECT).


  • Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography

    by Hiroto Yoneyama, Kenichi Nakajima, Koichi Okuda, Shinro Matsuo, Masahisa Onoguchi, Seigo Kinuya, Lars Edenbrandt


  • Validation of Left Ventricular Ejection Fraction with the IQ•SPECT System in Small-Heart Patients

    by Hiroto Yoneyama, Takayuki Shibutani, Takahiro Konishi, Asuka Mizutani, Ryosuke Hashimoto, Masahisa Onoguchi, Koichi Okuda, Shinro Matsuo, Kenichi Nakajima, Seigo Kinuya

    The IQ-SPECT system equipped with a multifocal (SMARTZOOM) collimator using an ordered subset conjugate gradient minimization (OSCGM) algorithm reduces the acquisition time of myocardial perfusion imaging (MPI) compared to conventional gamma cameras equipped with low-energy high-resolution (LEHR) collimators. We compared IQ-SPECT with a conventional single-photon emission computed tomography (SPECT) system for estimating the left ventricular ejection fraction (LVEF) in small-heart patients. Methods: The study group consisted of 98 consecutive patients who underwent a 1-day stress-rest MPI study with a 99mTc-labeled agent for preoperative risk assessment. Data were reconstructed using a filtered back projection (FBP) method for conventional SPECT, and an OSCGM algorithm for IQ-SPECT. End-systolic volume (ESV), end-diastolic volume (EDV), and LVEF were evaluated using quantitative software for gated perfusion SPECT (QGS) and cardioREPO (cREPO). We compared the LVEF of gated myocardial perfusion SPECT to echocardiographic measurements (Echo). Results: The EDV, ESV, and LVEF calculated by conventional SPECT, IQ-SPECT, and Echo showed good to excellent correlation using both QGS and cREPO. While LVEF calculated using QGS significantly differed between conventional SPECT (65.4 ± 13.8%) and IQ-SPECT (68.4 ± 15.2%; P = 0.0002), no significant difference was observed between IQ-SPECT (69.5 ± 11.0%) and conventional SPECT (69.5 ± 10.6%) for LVEF calculated using cREPO. In small-heart patients (ESV < 20 mL), a significant difference was observed between the LVEF calculated using the QGS of conventional SPECT (75.0 ± 9.6) and IQ-SPECT (79.5 ± 8.3) (P = 0.0005). No significant difference was observed between the LVEF calculated using the cREPO of conventional SPECT (72.3 ± 9.0%) and IQ-SPECT (74.3 ± 8.3%). Conclusion: The difference in calculated LVEF between IQ-SPECT and conventional SPECT was less with cREPO than with QGS in small-heart patients.


  • Open Access

    Comparison of diagnostic performance of four software packages for phase dyssynchrony analysis in gated myocardial perfusion SPECT

    by Koichi Okuda, Kenichi Nakajima, Shinro Matsuo, Soichiro Kashiwaya, Hiroto Yoneyama, Takayuki Shibutani, Masahisa Onoguchi, Mitsumasa Hashimoto, Seigo Kinuya

    Phase analysis of gated myocardial perfusion single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) dyssynchrony was investigated using the following dedicated software packages: Corridor4DM (4DM), cardioREPO (cREPO), Emory Cardiac Toolbox (ECTb), and quantitative gated SPECT (QGS). The purpose of this study was to evaluate the normal values of 95% histogram bandwidth, phase standard deviation (SD), and entropy and to compare the diagnostic performance of the four software packages. A total of 122 patients with normal myocardial perfusion and cardiac function (58.9 ± 12.3 years, 60 women, ejection fraction (EF) 74.3 ± 5.7%, and end-diastolic volume (EDV) 83.5 ± 3.6 mL) and 34 patients with suspected LV dyssynchrony (64.1 ± 12.2 years, 9 women, EF 52.0 ± 18.0%, and EDV 145.0 ± 6.8 mL) who underwent Tc-99m methoxy-isobutyl-isonitrile/tetrofosmin gated SPECT were retrospectively evaluated. Dyssynchrony indices of the 95% histogram bandwidth, phase SD, and entropy were computed with the four software programs. Diagnostic performance of LV phase dyssynchrony assessments was determined by receiver operator characteristic (ROC) analysis. The area under the ROC curve (AUC) was used to compare the software programs. The optimal cutoff point was determined by ROC curve based on the Youden index. The average of normal bandwidth significantly differed among the four software programs except in the comparison of 4DM and ECTb. Moreover, the normal phase SD significantly differed among the four software programs except in the comparison of cREPO and ECTb. The software programs showed high correlation levels for bandwidth, phase SD, and entropy (r ≥ 0.73, p < 0.001). ROC AUCs of bandwidth, phase SD, and entropy were ≥0.850, ≥0.858, and ≥0.900, respectively. Moreover, the ROC AUCs of bandwidth, phase SD, and entropy did not significantly differ among the four software programs. Optimal cutoff points for phase parameters were 24°–42° for bandwidth, 8.6°–15.3° for phase SD, and 31–48% for entropy. Although the optimal cutoff value for determining LV phase dyssynchrony by ROC analysis varied depending on the use of the different software programs, all software programs can be used reliably for phase dyssynchrony analysis.


  • Open Access

    Optimization of attenuation and scatter corrections in sentinel lymph node scintigraphy using SPECT/CT systems

    by Hiroto Yoneyama, Hiroyuki Tsushima, Masahisa Onoguchi, Takahiro Konishi, Kenichi Nakajima, Shinro Matsuo, Daiki Kayano, Hiroshi Wakabayashi, Anri Inaki, Seigo Kinuya

    Although SPECT/CT systems have been used for sentinel lymph node (SLN) imaging, few studies have focused on optimization of attenuation correction (AC) and scatter correction (SC). While SLNs could be detected in conventional planar images, they sometimes do not appear in SPECT/CT images. The purpose of this study was to investigate the optimal AC and SC and to improve the detectability of SLNs in examinations using SPECT/CT systems. The study group consisted of 56 female patients with breast cancer. In SPECT/CT imaging, four kinds of images were created with and without AC and SC; namely, AC−SC−, AC+SC−, AC−SC+ and AC+SC+. Five nuclear medicine physicians interpreted the planar and SPECT/CT images with five grades of confidence levels (1–5). The detection rate was calculated as the number of patients whose average confidence levels of interpretation were more than 4, divided by the total number of patients. The confidence level of interpretation and the detection rate provided by the planar images were 4.76 ± 0.49 and 94.6 %, respectively. In SPECT/CT imaging, the AC+SC− provided the best detection rate (confidence level of interpretation, 4.81 ± 0.38; detection rate, 98.2 %), followed by the AC−SC− (4.70 ± 0.55, 89.3 %), and the AC−SC+ (4.39 ± 1.2, 78.6 %). The lowest values were obtained for the AC+SC+ (4.36 ± 1.22, 78.6 %). Regarding the confidence levels of interpretation, significant differences were observed between AC+SC− and AC−SC−, AC+SC− and AC+SC+, AC+SC− and AC−SC+, and between planar images and AC+SC+ (P = 0.0021, 0.0009, 0.0013, and 0.0056, respectively). When SPECT/CT was used, AC improved the detection of SLNs. SC caused disappearance of a faint SLN in some cases and should not be performed.


  • Localization of Metastases from Malignant Pheochromocytoma in Patients Undergoing 131I-MIBG Therapy with Manually Fused 123I-MIBG SPECT and CT Images

    by Hiroto Kizu, Teruhiko Takayama, Hiroyuki Tsushima, Atsushi Noguchi, Kenichi Nakajima, Masahisa Onoguchi, Seigo Kinuya

    131I-metaiodobenzylguanidine (MIBG) has been used as a therapeutic agent for pheochromocytoma. Tumor localization and precise staging are essential for therapy with high-dose 131I-MIBG. The sites and extent of 123I-MIBG uptake are usually estimated to predict the effectiveness of therapy before administration. However, conventional scintigraphic images provide insufficient anatomic information. Therefore, we tried to manually superimpose 123I-MIBG SPECT and CT images using free software.


    • 1 September 2006
      • Vol. 34  (3) , 153-9

    Usefulness of medium-energy collimator for sentinel node lymphoscintigraphy imaging in breast cancer patients.

    by Hiroyuki Tsushima, Teruhiko Takayama, Takashi Yamanaga, Hiroto Kizu, Yoshihiro Shimonishi, Kazuhisa Kosakai, Atsushi Noguchi, Masahisa Onoguchi

    This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between a low-energy high-resolution (LEHR) collimator and a general-purpose ME collimator, and between energy windows centered at 141 keV and at 146 keV. Profile curves and image contrast were evaluated along with the visual interpretation of images. The most suitable imaging time was selected from the relationship between contrast and the data acquisition time. The images obtained with the general-purpose ME collimator and the energy window centered at 141 keV were of poorer quality than those obtained with the LEHR collimator and the same energy window. However, the quality of the images obtained with the general-purpose ME collimator improved when the energy window was centered at 146 keV. The method involving the general-purpose ME collimator and the energy window centered at 146 keV showed excellent image quality similar to that obtained with the LEHR collimator. The enhancement of contrast was confirmed at more than 3 cm away from the center of the injection site. Stable contrast was obtained with a data acquisition time of 5 min, with the general-purpose ME collimator, and with the energy window centered at 146 keV. The method involving the general-purpose ME collimator and the energy window centered at 146 keV has the merit of the lymph node not being concealed by a lead shield. This new method is expected to improve the rate of detection of SLN and has the potential for shortening the acquisition time.