Kenji Numata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenji Numata has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Kimio Tsubono
Department of Physics, The University of Tokyo
5 shared publications- Masaki Ando
The University of Tokyo
5 shared publications - Kazuhiro Yamamoto
Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582, Japan
4 shared publications Shigemi Otsuka
4 shared publications- Akito Araya
The University of Tokyo
3 shared publications - Nobuyuki Kanda
Osaka Metropolitan University
3 shared publications
Latest Publications
- 12 January 2012
- Published by Cambridge University Press (CUP)
- p. 108-128
Cryogenics
Introduction The use of cryogenic mirrors can be an attractive way of minimizing thermal noise due to optical coatings and substrates. As long as special care is taken in choosing materials, thermally induced fluctuations should be “frozen” at low temperatures. In this chapter, we introduce the current understanding of temperature dependence of mirror thermal noise, some practical design issues, and examples of cryogenic experiments.We will mainly focus on off-resonant thermal noise and physical cooling issues of macroscopic optics. For more on cooling of resonant thermal noise, see Chapter 16. Temperature dependence of mirror thermal noise In sensitive optical experiments, thermal fluctuations of coatings and substrates are important sources of noise and both tend to be reduced at cryogenic temperatures. The gains from cryogenics could come from several directions: the direct reduction of temperature itself, the decrease in mechanical losses (occurring in some materials), and the precipitous drop in specific heat and the increase in the mean free path of phonons. Appropriate materials and beam parameters must be adopted so that every kind of thermal noise is minimized by cryogenics simultaneously. Typically, Brownian thermal noise in coatings improves very slowly from cryogenics. This is due to a weak temperature dependence of mechanical loss. Coating thermal noise is also usually dominant over the substrate Brownian noise, so improvements of coating thermal noise directly impact measurement sensitivity. Substrate thermoelastic noise (see Chapter 7), coating thermo-optic noise (see Chapter 9), and other thermal noises (see Chapter 3) generally have less importance at cryogenic temperatures and at low frequencies.
- 12 January 2012
- Published by Cambridge University Press (CUP)
- p. 108-128
Cryogenics
Introduction The use of cryogenic mirrors can be an attractive way of minimizing thermal noise due to optical coatings and substrates. As long as special care is taken in choosing materials, thermally induced fluctuations should be “frozen” at low temperatures. In this chapter, we introduce the current understanding of temperature dependence of mirror thermal noise, some practical design issues, and examples of cryogenic experiments.We will mainly focus on off-resonant thermal noise and physical cooling issues of macroscopic optics. For more on cooling of resonant thermal noise, see Chapter 16. Temperature dependence of mirror thermal noise In sensitive optical experiments, thermal fluctuations of coatings and substrates are important sources of noise and both tend to be reduced at cryogenic temperatures. The gains from cryogenics could come from several directions: the direct reduction of temperature itself, the decrease in mechanical losses (occurring in some materials), and the precipitous drop in specific heat and the increase in the mean free path of phonons. Appropriate materials and beam parameters must be adopted so that every kind of thermal noise is minimized by cryogenics simultaneously. Typically, Brownian thermal noise in coatings improves very slowly from cryogenics. This is due to a weak temperature dependence of mechanical loss. Coating thermal noise is also usually dominant over the substrate Brownian noise, so improvements of coating thermal noise directly impact measurement sensitivity. Substrate thermoelastic noise (see Chapter 7), coating thermo-optic noise (see Chapter 9), and other thermal noises (see Chapter 3) generally have less importance at cryogenic temperatures and at low frequencies.
- 1 January 2010
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 8 (ists27) , Po_4_1-Po_4_6
DECIGO: the Japanese Space Gravitational Wave Antenna
A space gravitational wave antenna, DECIGO (DECI-hertz interferometer Gravitational wave Observatory) will provide fruitful insights into the universe, particularly on dark energy, the formation mechanism of supermassive black holes, and the inflation of the universe. In the current pre-conceptual design, DECIGO will be comprised of 4 interferometer units; each interferometer unit will be realized by formation flight of three drag-free spacecraft with 1000 km separation. Since DECIGO will be an extremely challenging mission with high-precision formation flight, it is important to increase the technical feasibility before its planned launch in 2024. Thus, we are planning two milestone missions. DECIGO pathfinder (DPF) is the first milestone mission for DECIGO, and key components for DPF are being tested on ground and in orbit. In this article, we review the conceptual design and current status of DECIGO and DPF.
- 1 January 2010
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 8 (ists27) , Po_4_1-Po_4_6
DECIGO: the Japanese Space Gravitational Wave Antenna
A space gravitational wave antenna, DECIGO (DECI-hertz interferometer Gravitational wave Observatory) will provide fruitful insights into the universe, particularly on dark energy, the formation mechanism of supermassive black holes, and the inflation of the universe. In the current pre-conceptual design, DECIGO will be comprised of 4 interferometer units; each interferometer unit will be realized by formation flight of three drag-free spacecraft with 1000 km separation. Since DECIGO will be an extremely challenging mission with high-precision formation flight, it is important to increase the technical feasibility before its planned launch in 2024. Thus, we are planning two milestone missions. DECIGO pathfinder (DPF) is the first milestone mission for DECIGO, and key components for DPF are being tested on ground and in orbit. In this article, we review the conceptual design and current status of DECIGO and DPF.
- 26 August 2004
- Published by American Physical Society (APS) in Physical Review D
- Vol. 70 (4) , 042003
Coincidence analysis to search for inspiraling compact binaries using TAMA300 and LISM data
Japanese laser interferometric gravitational wave detectors, TAMA300 and LISM, performed a coincident observation during 2001. We perform a coincidence analysis to search for inspiraling compact binaries. The length of data used for the coincidence analysis is 275 hours when both TAMA300 and LISM detectors are operated simultaneously. TAMA300 and LISM data are analyzed by matched filtering, and candidates for gravitational wave events are obtained. If there is a true gravitational wave signal, it should appear in both data of detectors with consistent waveforms characterized by masses of stars, amplitude of the signal, the coalescence time and so on. We introduce a set of coincidence conditions of the parameters, and search for coincident events. This procedure reduces the number of fake events considerably, by a factor compared with the number of fake events in single detector analysis. We find that the number of events after imposing the coincidence conditions is consistent with the number of accidental coincidences produced purely by noise. We thus find no evidence of gravitational wave signals. We obtain an upper limit of 0.046 [1/h] to the galactic event rate within 1 kpc from the Earth. The method used in this paper can be applied straightforwardly to the case of coincidence observations with more than two detectors with arbitrary arm directions.- 26 August 2004
- Published by American Physical Society (APS) in Physical Review D
- Vol. 70 (4) , 042003
Coincidence analysis to search for inspiraling compact binaries using TAMA300 and LISM data
Japanese laser interferometric gravitational wave detectors, TAMA300 and LISM, performed a coincident observation during 2001. We perform a coincidence analysis to search for inspiraling compact binaries. The length of data used for the coincidence analysis is 275 hours when both TAMA300 and LISM detectors are operated simultaneously. TAMA300 and LISM data are analyzed by matched filtering, and candidates for gravitational wave events are obtained. If there is a true gravitational wave signal, it should appear in both data of detectors with consistent waveforms characterized by masses of stars, amplitude of the signal, the coalescence time and so on. We introduce a set of coincidence conditions of the parameters, and search for coincident events. This procedure reduces the number of fake events considerably, by a factor compared with the number of fake events in single detector analysis. We find that the number of events after imposing the coincidence conditions is consistent with the number of accidental coincidences produced purely by noise. We thus find no evidence of gravitational wave signals. We obtain an upper limit of 0.046 [1/h] to the galactic event rate within 1 kpc from the Earth. The method used in this paper can be applied straightforwardly to the case of coincidence observations with more than two detectors with arbitrary arm directions.- Open Access
Systematic measurement of the intrinsic losses in various kinds of bulk fused silica
We systematically measured and compared the mechanical losses of various kinds of bulk fused silica. Their quality factors ranged widely from 7x10^5 to 4x10^7, the latter being one of the highest reported among bulk fused silica. We observed frequency-dependent losses and a decrease in the losses upon annealing.
Open AccessSystematic measurement of the intrinsic losses in various kinds of bulk fused silica
We systematically measured and compared the mechanical losses of various kinds of bulk fused silica. Their quality factors ranged widely from 7x10^5 to 4x10^7, the latter being one of the highest reported among bulk fused silica. We observed frequency-dependent losses and a decrease in the losses upon annealing.
- 29 December 2003
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 91 (26) , 260602
Wide-Band Direct Measurement of Thermal Fluctuations in an Interferometer
We directly measured mechanical thermal fluctuations in mirrors over three decades of frequency range using a short-length Fabry-Perot interferometer. This is the first such measurement at wide off-resonant frequency band that is much lower than mechanical resonant frequencies. Theoretically, the mechanical fluctuation in mirrors had been thought to become the principal noise in precise interferometry, such as in gravitational wave detection. We identified the thermally induced noises in the interferometer, the so-called substrate Brownian noise, substrate thermoelastic noise, and coating Brownian noise.
- 29 December 2003
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 91 (26) , 260602
Wide-Band Direct Measurement of Thermal Fluctuations in an Interferometer
We directly measured mechanical thermal fluctuations in mirrors over three decades of frequency range using a short-length Fabry-Perot interferometer. This is the first such measurement at wide off-resonant frequency band that is much lower than mechanical resonant frequencies. Theoretically, the mechanical fluctuation in mirrors had been thought to become the principal noise in precise interferometry, such as in gravitational wave detection. We identified the thermally induced noises in the interferometer, the so-called substrate Brownian noise, substrate thermoelastic noise, and coating Brownian noise.
- 15 March 2002
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 19 (7) , 1697-1702
Intrinsic losses in various kinds of fused silica
- 15 March 2002
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 19 (7) , 1697-1702
Intrinsic losses in various kinds of fused silica
- 1 February 2001
- Published by American Physical Society (APS) in Physical Review D
- Vol. 63 (6) , 062001
First search for gravitational waves from inspiraling compact binaries using TAMA300 data
We analyzed 6 hours of data from the TAMA300 detector by matched filtering, searching for gravitational waves from inspiraling compact binaries. We incorporated a two-step hierarchical search strategy in matched filtering. We obtained an upper limit of 0.59/hour (C.L.=90%) on the event rate of inspirals of compact binaries with a mass between and and with a signal-to-noise ratio greater than 7.2. The distance of binaries which produce the signal-to-noise ratio 7.2 was estimated to be 6.2 kpc (2.9 kpc) when the position of the source in the sky and the inclination angle of the binaries were optimal.- 1 February 2001
- Published by American Physical Society (APS) in Physical Review D
- Vol. 63 (6) , 062001
First search for gravitational waves from inspiraling compact binaries using TAMA300 data
We analyzed 6 hours of data from the TAMA300 detector by matched filtering, searching for gravitational waves from inspiraling compact binaries. We incorporated a two-step hierarchical search strategy in matched filtering. We obtained an upper limit of 0.59/hour (C.L.=90%) on the event rate of inspirals of compact binaries with a mass between and and with a signal-to-noise ratio greater than 7.2. The distance of binaries which produce the signal-to-noise ratio 7.2 was estimated to be 6.2 kpc (2.9 kpc) when the position of the source in the sky and the inclination angle of the binaries were optimal.