BLBernd G. Lapatki

Bernd G. Lapatki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bernd G. Lapatki has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Irmtrud E. Jonas

    Professor and Department Chair, Department of Orthodontics, School of Dental Medicine, University of Freiburg, Freiburg i.Br., Germany

    2 shared publications
  • Dick F. Stegeman

    1 shared publication
  • Dirk Baustert

    Research Assistant, Department of Orthodontics, School of Dental Medicine, University of Freiburg, Freiburg i.Br., Germany

    1 shared publication
  • I.E. Jonas

    Department of Orthodontics, School of Dental Medicine, University of Freiburg, Hugstetter Str. 55, D-79106 Freiburg i.Br., Germany; and

    1 shared publication
  • J. Bartholomeyczik

    Department of Orthodontics, School of Dental Medicine, University of Freiburg, Hugstetter Str. 55, D-79106 Freiburg i.Br., Germany; and

    1 shared publication
  • Johannes Petrus van Dijk

    Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands

    1 shared publication

Latest Publications

  • Smart Brackets for 3D-Force-Moment Measurements in Orthodontic Research and Therapy – Developmental Status and Prospects*

    by Bernd G. Lapatki, Oliver Paul

    Quantitative knowledge of the three-dimensional (3D) force-moment systems applied for therapeutic tooth movement is of utmost importance, with regard to the predictability of the course of tooth movement, as well as the reduction of traumatic side effects. The concept of a smart bracket with an integrated sensor system for 3D force and moment measurement has recently been published. The feasibility of this approach has been demonstrated using finite-element (FE) simulations and a 2.5 times enlarged real smart bracket model. The aim of this study was to develop and to mechanically characterize the first wire-mediated, true-scale smart bracket. A true-scale smart bracket was built using a stress-sensor chip (having a surface area of 2 × 2.5 mm2) and a conventional bracket slot. This bracket was calibrated on a biomechanical system for 3D application and measurement of forces and moments, then its measurement accuracy was evaluated. With the exception of the bucco-lingually-oriented force component, the embedded sensor system was capable of reconstructing the applied force-moment components with sufficient accuracy. The standard deviations for the differences between applied and inferred values were 0.07 N, 0.07 N and 0.26 N for the components F x , F y and F z , and 0.76 Nmm, 1.09 Nmm and 0.22 Nmm for the components Mx, My and Mz. We were able to construct true-scale, wire-mediated smart brackets. Work on improving the sensor system's buccolingual sensitivity is still in progress. Improved smart brackets with wire-mediated energy transmission could be applied in the near future in orthodontic training as an objective feedback tool, as well as in biomechanical research. Broad clinical application of smart brackets requires integration of telemetric components for data and energy transmission. Such components are now being developed. Future clinical application of smart brackets may contribute in reducing the negative side effects of fixed appliance therapy such as root resorption, while enhancing therapeutic efficiency. Die quantitative Kenntnis der im Rahmen der therapeutischen Zahnbewegung auf die einzelnen Zähne übertragenen dreidimensionalen (3-D) Kraft-Drehmoment-Systeme ist hinsichtlich der Richtungskontrolle bzw. Vorhersagbarkeit der Zahnbewegung sowie der Reduzierung von traumatischen Begleiterscheinungen von eminenter Bedeutung. Im Rahmen einer früheren Arbeit wurde ein Konzept für intelligente Brackets mit integriertem Sensorsystem für 3-D-Kraft-/Drehmomentmessungen vorgestellt und dessen Realisierbarkeit mittels Finite-Elemente-(FE-)Simulationen sowie anhand eines 2,5fach vergrößerten Smart-Bracket-Modells demonstriert. Ziel der vorliegenden Arbeit war die erstmalige Entwicklung und mechanische Charakterisierung eines (kabelversorgten) Smart Brackets im Maßstab 1:1. Aus einem Stress-Sensorchip mit einer Oberfläche von 2 × 2,5 mm2 sowie einem konventionellen Bracketslot wurde ein maßstabsgetreues Smart Bracket aufgebaut. Dieses wurde auf einem biomechanischen Messplatz zur 3-D-Applikation und 3-D-Messung von Kräften und Drehmomenten kalibriert und anschließend hinsichtlich seiner Messgenauigkeit evaluiert. Mit Ausnahme der in bukkolingualer Richtung orientierten Kraftkomponente war das im Bracket integrierte Sensorsystem in der Lage, die applizierten Kraft- und Drehmomentkomponenten (aus klinischer Sicht) hinreichend genau zu rekonstruieren. Die entsprechenden Standardabweichungen für die Differenzen zwischen applizierten und (mithilfe der Stress-Sensorsignale) rekonstruierten Werte betrugen 0,07 N, 0,07 N, und 0,26 N für die Komponenten F x , F y und F z bzw. 0,76 Nmm, 1,09 Nmm, und 0,22 Nmm für die Komponenten M x , M y und M z . Die Realisierung von maßstabsgetreuen, kabelversorgten Smart Brackets ist möglich, wobei derzeit noch an einer Optimierung des Sensorsystems hinsichtlich seiner Sensitivität für bukkolinguale Kräfte gearbeitet wird. Optimierte Smart-Bracket-Versionen mit Kabelversorgung können in naher Zukunft als objektives Feedback-Tool in der kieferorthopädischen Aus- und Weiterbildung sowie in der biomechanischen Grundlagenforschung eingesetzt werden. Die breite klinische Anwendung von Smart Brackets erfordert die Integration von telemetrischen Komponenten der Daten- und Energieübertragung, deren Entwicklung momentan vorangetrieben wird. Die zukünftige klinische Anwendung von intelligenter Brackettechnologie in der festsitzenden kieferorthopädischen Therapie könnte dazu beitragen, dass die negativen therapeutischen Begleiterscheinungen (wie z. B. Wurzelresorptionen) reduziert und die therapeutische Effizienz gesteigert wird.


  • Smart Bracket for Multi-dimensional Force and Moment Measurement

    by B.G. Lapatki, J. Bartholomeyczik, P. Ruther, I.E. Jonas, O. Paul

    Atraumatic, well-directed, and efficient tooth movement is interrelated with the therapeutic application of adequately dimensioned forces and moments in all three dimensions. The lack of appropriate monitoring tools inspired the development of an orthodontic bracket with an integrated microelectronic chip equipped with multiple piezoresistive stress sensors. Such a ‘smart bracket’ was constructed (scale of 2.5:1) and calibrated. To evaluate how accurately the integrated sensor system allowed for the quantitative determination of three-dimensional force-moment systems externally applied to the bracket, we exerted 396 different force-moment combinations with dimensions within usual therapeutic ranges (± 1.5 N and ± 15 Nmm). Comparison between the externally applied force-moment components and those reconstructed on the basis of the stress sensor signals revealed very good agreement, with standard deviations in the differences of 0.037 N and 0.985 Nmm, respectively. We conclude that our methodological approach is generally suitable for monitoring the relatively low forces and moments exerted on individual teeth with fixed orthodontic appliances.


  • Lip-to-incisor Relationship and Postorthodontic Long-term Stability of Cover-bite Treatment

    by Bernd G. Lapatki, Dirk Baustert, Jürgen Schulte-Mönting, Sibylle Frucht, Irmtrud E. Jonas

    Objective: To investigate the impact of a persisting high lip line and other potential relapse-inducing factors on long-term stability of orthodontic correction of retroinclined maxillary central incisors. Materials and Methods: Thirty-one cover-bite (“Deckbiss”) patients with retroinclined maxillary central incisors and a deep frontal overbite were evaluated. The maxillary central incisor inclination was determined odontometrically with study models made pretreatment, posttreatment, and at a follow-up examination (mean posttherapeutic interval: 9.0 years). The lip-to-incisor relationship, the interincisal angle, and the anteroposterior maxillary central incisor position were measured on lateral cephalograms taken after active treatment. Results: The relapse tendency of the orthodontic correction of the retroinclined maxillary central incisors displayed great interindividual variability with a range of posttherapeutic inclination change of −6.75° to +8.00°. Multiple regression analysis revealed an increased tendency for relapse in patients with (1) a high posttherapeutic (dorsal) lip line level combined with the maxillary central incisor and lower lip contact only in the incisal crown area (P < .01) and (2) a marked therapeutically induced inclination change of the maxillary central incisors (P < .05). Interrelations between the relapse of the corrected maxillary central incisors and other evaluated parameters were not statistically significant. Conclusions: For maximum treatment stability, the elimination of an excessive overlap of the upper incisors by the lower lip should be regarded as one of the most important therapeutic objectives when treating this malocclusion.


  • Open Access

    Topographical Characteristics of Motor Units of the Lower Facial Musculature Revealed by Means of High-Density Surface EMG

    by Bernd G. Lapatki, Robert Oostenveld, Johannes P. Van Dijk, Irmtrud E. Jonas, Machiel J. Zwarts, Dick F. Stegeman

    The objective of this study was to systematically characterize motor units (MUs) of the musculature of the lower face. MU endplate positions and principal muscle fiber orientations relative to facial landmarks were identified. This was done by the analysis of motor unit action potentials (MUAPs) in the surface electromyogram. Thirteen specially trained, healthy subjects performed selective contractions of the depressor anguli oris, depressor labii inferioris, mentalis, and orbicularis oris inferior muscles. Signals were recorded using recently developed, 0.3-mm thin and flexible high-density surface electromyography (sEMG) grids (120 channels). For each subject and each muscle and for different low contraction levels, representative MUAPs (“MU fingerprints”) were extracted from the raw sEMG data according to their spatiotemporal amplitude characteristics. We then topographically characterized the lower facial MUs' endplate zones and main muscle fiber orientations on the individual faces of the subjects. These topographical MU parameters were spatially warped to correct for the different sizes and shapes of the faces of individual subjects. This electrophysiological study revealed a distribution of the lower facial MU endplates in more or less restricted, distinct clusters on the muscle often with eccentric locations. The results add substantially to the basic neurophysiologic and anatomical knowledge of the complex facial muscle system. They can also be used to establish objective guidelines for placement of conventional (surface or needle) EMG electrodes as well as for clinical investigations on neuromuscular diseases affecting the facial musculature. The localized endplate positions may also indicate optimal locations for botulinum toxin injection in the face.