Jan A. Visser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan A. Visser has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
D. J. de Kock
Department of Mechanical and Aeronautical Engineering, University of Pretoria, Pretoria 0002, South Africa
1 shared publication
Latest Publications
- 9 August 2002
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 18 (10) , 721-727
Optimization of heat sink mass using the DYNAMIC‐Q numerical optimization method
Heat sink designers have to balance a number of conflicting parameters to maximize the performance of a heat sink. This must be achieved within the given constraints of size or volume of the heat sink as well as the mass or material cost of the heat sink. This multi‐parameter problem lends itself naturally to optimization techniques. Traditionally, an experimental approach was used where different heat sink designs were constructed and their performance measured. This approach is both time consuming and costly. More recently, numerical CFD techniques have been used, but mostly on a trial‐and‐error basis, and is basically the numerical equivalent of the experimental approach. A better approach is to combine a semi‐empirical simulation program with mathematical optimization techniques. This paper describes the use of mathematical optimization techniques to minimize heat sink mass. The simulation uses the Qfin 2.1 code, while the optimization is carried out by means of the DYNAMIC‐Q method. This method is extremely robust and specifically designed to handle constrained problems where the objective and/or constraint functions are expensive to evaluate. The paper illustrates how the parameters considered influence the heat sink mass and how mathematical optimization techniques can be used by the heat sink designer to design compact heat sinks for different types of electronic enclosures. Copyright © 2002 John Wiley & Sons, Ltd.
- 9 August 2002
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 18 (10) , 721-727
Optimization of heat sink mass using the DYNAMIC‐Q numerical optimization method
Heat sink designers have to balance a number of conflicting parameters to maximize the performance of a heat sink. This must be achieved within the given constraints of size or volume of the heat sink as well as the mass or material cost of the heat sink. This multi‐parameter problem lends itself naturally to optimization techniques. Traditionally, an experimental approach was used where different heat sink designs were constructed and their performance measured. This approach is both time consuming and costly. More recently, numerical CFD techniques have been used, but mostly on a trial‐and‐error basis, and is basically the numerical equivalent of the experimental approach. A better approach is to combine a semi‐empirical simulation program with mathematical optimization techniques. This paper describes the use of mathematical optimization techniques to minimize heat sink mass. The simulation uses the Qfin 2.1 code, while the optimization is carried out by means of the DYNAMIC‐Q method. This method is extremely robust and specifically designed to handle constrained problems where the objective and/or constraint functions are expensive to evaluate. The paper illustrates how the parameters considered influence the heat sink mass and how mathematical optimization techniques can be used by the heat sink designer to design compact heat sinks for different types of electronic enclosures. Copyright © 2002 John Wiley & Sons, Ltd.
- 18 August 2000
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 16 (9) , 637-648
A simplified equation to predict heat transfer in an internal duct of a gas turbine nozzle guide vane
- 18 August 2000
- Published by Wiley in Communications in Numerical Methods in Engineering
- Vol. 16 (9) , 637-648
A simplified equation to predict heat transfer in an internal duct of a gas turbine nozzle guide vane
- Open Access
- 7 June 1999
- Published by ASME International
A Simplified Equation to Obtain the Complex Heat Transfer Distribution in an Internal Duct of a Semi-Cooled Turbine Blade
Due to the three-dimensional shape of the internally cooling channels of a modern gas turbine blade, the heat transfer rate varies substantially between the different sides of the channels. This detailed heat flux and resulting temperature distribution on the walls are important to improve the design of the blade as well as to determine the durability of the blade. This detail heat transfer data is usually obtained by means of a complex three-dimensional simulation of the blade configuration. Therefore, for design purposes, the heat transfer data on the channel surfaces is often assumed to be the average heat transfer rate on the channel walls. The average heat transfer rate can be obtained by using a simplified heat transfer equation, based on the average Reynolds number in the channel. This paper presents a simplified formula that can be used to obtain the detailed heat transfer rate in square and non-square cooling channels of a stationary, as well as a rotating turbine blade. The simplified formula is based on results obtained from three-dimensional simulations of the heat transfer in the channels and was compared to simulated and experimental data over a range in flow rates and channel geometries. In general, it can be concluded that the formulation produces fast and accurate results over a wide range of applications.
- 7 June 1999
- Published by ASME International
Open AccessA Simplified Equation to Obtain the Complex Heat Transfer Distribution in an Internal Duct of a Semi-Cooled Turbine Blade
Due to the three-dimensional shape of the internally cooling channels of a modern gas turbine blade, the heat transfer rate varies substantially between the different sides of the channels. This detailed heat flux and resulting temperature distribution on the walls are important to improve the design of the blade as well as to determine the durability of the blade. This detail heat transfer data is usually obtained by means of a complex three-dimensional simulation of the blade configuration. Therefore, for design purposes, the heat transfer data on the channel surfaces is often assumed to be the average heat transfer rate on the channel walls. The average heat transfer rate can be obtained by using a simplified heat transfer equation, based on the average Reynolds number in the channel. This paper presents a simplified formula that can be used to obtain the detailed heat transfer rate in square and non-square cooling channels of a stationary, as well as a rotating turbine blade. The simplified formula is based on results obtained from three-dimensional simulations of the heat transfer in the channels and was compared to simulated and experimental data over a range in flow rates and channel geometries. In general, it can be concluded that the formulation produces fast and accurate results over a wide range of applications.