BLBaolin Liu

Baolin Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Baolin Liu has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • Dehua Li

    State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology The Fourth Military Medical University Xi'an China

    5 shared publications
  • Kaijin Hu

    State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Clinical Research Center for Oral Diseases Department of Oral and Maxillofacial Surgery School of Stomatology The Fourth Military Medical University Xi'an China

    4 shared publications
  • Yingliang Song

    Department of Implant Dentistry, School of Stomatology, Fourth Military Medical University, Xi'an, China

    4 shared publications
  • Liang Kong

    3 shared publications
  • Dehua Li

    State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Dental Implants, School of Stomatology, Fourth Military Medical University, Xi'an, Shaanxi 710032, P.R. China

    2 shared publications
  • Jin Yang

    2 shared publications

Latest Publications

  • Open Access

    Enhanced osseointegration of titanium implants in a rat model of osteoporosis using multilayer bone mesenchymal stem cell sheets

    by Yan Duan, Wei Ma, Dehua Li, Tongfei Wang, Baolin Liu

    The present study aimed to investigate whether bone marrow‑derived mesenchymal stem cell (BMSC) sheets combined with titanium implants enhanced implant osseointegration in an ovariectomized (OVX) rat model of osteoporosis. Sprague‑Dawley rats were randomly assigned into a test group and control group. Allogenic BMSCs were collected from the rats, cultured and stored via cryopreservation. At 6 months post‑ovariectomy, establishment of the OVX model was confirmed by micro‑computed tomography (CT) measurements. BMSC sheets were subsequently layered and wrapped over titanium implants for implantation. Unmodified implants served as the control. At 8 weeks post‑implantation, samples were observed by micro‑CT reconstruction and histomorphometric evaluation. Micro‑CT reconstruction identified a marked improvement in the surrounding bone volume following treatment, with data analyses indicating a significant increase in bone volume in the BMSC‑implant group compared with the control implant group (P<0.05). In addition, histological staining identified new bone formation and an increased rate of bone‑implant contact surrounding the BMSC‑implant constructs. These results indicate that the use of BMSC sheets as a novel tissue engineering approach improves the osseointegration of titanium implants in an osteoporosis model. This method may expand the operative indications in patients with osteoporosis and improve the success rate of clinical dental implant treatments.


  • The Adhesion AND Growth of Both the Human Primary Gingival Epithelial Cells and Streptococcus Mutans on Micro-Arc Oxidized Titanium

    by Jiangning Lv, Hongwei Li, Ying Mu, ShuMin Wang, Jing Sun, Jun Jiang, Ping Ding, Baolin Liu

    With good osseointegration properties, micro-arc oxidation has now gradually become the key point in basic research and clinical trials, but interface between the implant surface treated by micro-arc oxidation and gingival soft tissues has been seldom reported. The influences of micro-arc oxidation surface treatment on the biological behavior of primary human gingival epithelial cells (hGEC) and common pathogen Streptococcus mutans have been studied. MTT method was taken to test the adhesion and growth of hGEC on different treated surfaces. No significant changes were found between with or without MAO- treated surface. However, higher growth rate was observed in MAO group at first and third days, although it showed no significant difference at fifth and seventh day. Secretions of EGF of the cells grown on both surfaces were also no big changes (P > 0.05). RT-PCR showed adhesion gene of hGEC, E-cad on the first day of micro-arc oxidation surface treatment, expression level is higher than that of polishing group (P < 0.05), but no significant difference of the expression levels of Itgβ1, PCNA, and EGF. Finally, easier adhesion and high growth rate of Streptococcus mutans were found at MAO-treated surface (P < 0.05). In conclusion, our data suggested MAO-treated Ti surface may favor epithelial cell adhesion, but it also increase the risk of bacterial infection.


  • Preparation and in vitro biocompatibility of hybrid oxide layer on titanium surface

    by Wei Ma, Shao-Hai Wang, Guo-Feng Wu, Bao-Lin Liu, Jian-Hua Wei, Chao Xie, De-Hua Li


    • 18 November 2009
      • Vol. 22  (6) , 607-15

    Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

    by Liang Kong, Zexu Gu, Tao Li, Junjie Wu, Kaijin Hu, Yanpu Liu, Hongzhi Zhou, Baolin Liu

    A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.


    • 1 October 2009
      • Vol. 29  (5) , 523-33

    Bone healing process around distraction implants following alveolar distraction osteogenesis: a preliminary experimental study in dogs.

    by Yunzhuan Zhao, Yanpu Liu, Baolin Liu, Yinghuai Zhang, Zhiyu Jia, Lei Wang, Liang Kong

    In this study, a new type of distraction implant (DI) that could be transformed into a prosthetic implant after distraction was applied to augment the alveolar ridge, and the bone response around it was observed in six dogs. Two DIs were placed into the lateral edentulous submandibular ridge after osteotomy. The DIs were left to integrate into the bone after 8 days of distraction at a rate of 1 mm per day. Specimens were obtained at 5, 8, and 12 weeks after distraction. Radiopacity of the regenerated bone increased steadily during the consolidation period. After 12 weeks, homogeneous bone density was observed. Histologic examination showed osseointegration of the whole DI in the region of the threads in the native bone and in the regenerated area 12 weeks later. These results suggest that simultaneous bone regeneration in a distracted gap and osseointegration of DIs in an augmented alveolar ridge can be achieved. The overall treatment time could be shortened significantly with this method. (Int J Periodontics Restorative Dent 2009;29:523-533.).


  • Inhibition of CD146 gene expression via RNA interference reduces in vitro perineural invasion on ACC‐M cell

    by W. Chen, H. L. Zhang, Y. G. Jiang, J. H. Li, B. L. Liu, M. Y. Sun

    Background:  Overexpression of melanoma cell adhesion molecule (MCAM or CD146), a novel member of the immunoglobulin gene superfamily, promotes invasion, metastasis, growth and survival of malignant cells.Materials and methods:  Here, we used a human U6 promoter‐driven DNA template approach to induce short hairpin RNA (shRNA)‐triggered RNA interference to block CD146 gene expression in the human high‐metastatic adenoid cystic carcinoma (ACC) cell line ACC‐M. reverse transcription‐polymerase chain reaction, Western blot, 3‐(4,5‐dimethylthiazol‐2‐yl)‐2,5‐diphenyl‐2H‐tetrazolium bromide assay, flow cytometry analysis and in vitro perineural invasion (PNI) assay were used to investigate the effects of CD146 on cell growth, cell cycle distribution and cell PNI activity in ACC‐M cells.Results:  We have demonstrated that different shRNAs can specifically knockdown the transcription of CD146, resulting in the inhibition of cell proliferation, and G0/G1 to S phase arrest in ACC‐M cells. Knockdown of CD146 by shRNA resulted in decrease of the ACC‐M PNI activity in vitro.Conclusion:  These findings suggested that CD146 was an ACC‐related gene and CD146 may play an important role in the carcinogenesis, progression and PNI activity of ACC.


    • 18 April 2008
      • Vol. 23  (1) , 65-74

    Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.

    by Liang Kong, Kaijin Hu, Dehua Li, Yingliang Song, Jin Yang, Ziyan Wu, Baolin Liu

    To evaluate continuous and simultaneous variations of thread height and width for an experimental screw-type implant. A finite element model of an implant with a V-shaped thread was created. The range of thread height was set at 0.20 to 0.60 mm, and the range of thread width was set at 0.10 to 0.40 mm. Forces of 100 N and 50 N were applied along the implant axis (AX) and an angle of 45 degrees in a buccolingual direction (45-degree BL), respectively. The maximum von Mises stresses in jawbone were evaluated, and the sensitivity of the stress in jawbone to the variables was also evaluated. Under AX load, the maximum von Mises stresses in cortical and cancellous bones increased by 4.3% and 63.0%, respectively, as thread parameters changed. Under 45-degree BL load, maximum von Mises stresses in cortical and cancellous bones increased by 19.3% and 118.0%, respectively. When thread height was from 0.34 to 0.50 mm and thread width was 0.18 to 0.30 mm, the tangent slope of the maximum von Mises stress response curve ranged from -1 to 1. The variation of the maximum von Mises stresses in jawbone was more sensitive to thread height than to thread width. Stress in cancellous bone is more likely to be influenced by thread parameters than stress in cortical bone. A 45-degree BL force is more likely to be influenced by thread parameters than an axial force. A thread height of 0.34 to 0.50 mm and a thread width of 0.18 to 0.30 mm is optimal from a biomechanical point of view. In the design of a screw-type implant, thread height is more important than thread width for the reduction of stress within the bone.


  • Bivariate Evaluation of Cylinder Implant Diameter and Length: A Three‐Dimensional Finite Element Analysis

    by Liang Kong, Yingying Sun, Kaijin Hu, Dehua Li, Rui Hou, Jin Yang, Baolin Liu

    Purpose: To evaluate continuous and simultaneous variations of implant diameter and length for an experimental cylinder implant. Materials and Methods: A finite element model of a mandible segment with implant was created. The range of implant diameter (D) was set from 2.5 to 5.0 mm, and that of implant length (L) from 6.0 to 16.0 mm. The maximum Von Mises stresses in the mandible were evaluated, and the sensitivity of the stresses in the mandible to the variables was also evaluated. Results: Under axial load, the maximum von Mises stresses in cortical and cancellous bones decreased by 73.3% and 69.4%, respectively, with D and L increasing. Under buccolingual load, those decreased 83.8% and 79.2%, respectively. When D exceeded 3.9 mm and L exceeded 10.0 mm, the tangent slope rate of the maximum von Mises stress response curve ranged from −1 to 0. The variation of the maximum von Mises stresses in the mandible was more sensitive to D than to L. Conclusions: Buccolingual force is apt to be influenced by the two implant parameters; implant diameter and length favor stress distribution in cortical bone and cancellous bone, respectively. Implant diameter exceeding 3.9 mm and implant length exceeding 10.0 mm are the optimal choice for type B/2 bone in a cylinder implant. The implant diameter is more important than length in reducing bone stress.


    • 1 August 2007
      • Vol. 25  (4) , 358-61

    [Diameter and length double objectives robust analysis of cylinder dental implant].

    by Ying-Ying Sun, Liang Kong, Bao-Lin Liu, Kai-Jin Hu, De-Hua Li, Li Song

    To determine the jaw bone stress variation affected by cylinder implant diameter and length simultaneously in Ansys DesignXplorer module. Finite element model of segment mandible with a cylinder implant was created. The range of the implant diameter (D) and length (L) were set from 2.5 mm to 5.0 mm and from 6.0 mm to 16.0 mm respectively. The maximum Von Mises stresses in jaw bone and sensitivity to D and L were evaluated. Under axial (buccolingual) load, when one variable equaled to median, the amplification of maximum Von Mises stresses in cortical bone and cancellous bone were 44.66% (71.32%) and 51.45% (58.50%) respectively with the D increasing. The amplification of maximum Von Mises stresses in cortical bone and cancellous bone were 45.97% (21.66%) and 52.15% (37.75%) respectively with the L increasing. When D exceeded 3.7 mm and L exceeded 10.0 mm, the response curve curvatures of maximum Von Mises stresses to L and D in jaw bone ranged from -1 to 0. And the variation of the maximum Von Mises stresses in jaw bone was more sensitive to D than to L. Stresses in jaw bone under buccolingual and axial load are apt to be affected by implant diameter and length respectively. And to a cylinder implant, the diameter exceeds 3.7 mm and length exceeds 10.0 mm are optimal selections. Diameter should pay more attention to than to length for cylinder implant. Expanding the width of the jaw bone is more important than expanding the height of the jaw bone in clinical experience.

    • 1 December 2006
      • Vol. 24  (6) , 509-12, 515

    [Optimized thread pitch design and stress analysis of the cylinder screwed dental implant].

    by Liang Kong, Bao-Lin Liu, Kai-Jin Hu, De-Hua Li, Ying-Liang Song, Pan Ma, Jin Yang

    To determine the optimal thread pitch for an experimental cylinder implant in Ansys Work-bench Design Xplorer environment. Finite element models of segment jaw bone with a V-shaped thread implant were created. The thread pitch (P) was set from 0.5 mm to 1.6 mm. The maximum Equivalent stresses (EQV stresses) in jaw bone and in implant were evaluated. Under axial load, the amplification of maximum EQV stresses in cortical bone, cancellous bone and implant were 7.1%, 123.4% and 28.7% respectively. Under bucco-lingual load, the amplification of maximum EQV stresses in cortical bone, cancellous bone and implant were 2.8%, 28.8% and 14.9% respectively. When P exceeded 0.8 mm, the response curve curvature of maximum EQV stresses in jaw bone and in implant to P was ranged from -1 to 1. Stresses in cancellous bone are more sensitive to thread pitch than in cortical bone. Stresses in jaw bone under axial load are easier affected by thread pitch than under bucco-lingual load. Thread pitch plays a greater role in protecting dental implant under axial load than under bucco-lingual load. Thread pitch exceed 0.8 mm should be the optimal design in a cylinder implant, but oversized pitch should be avoided too.