E. Jolivet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
E. Jolivet has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
W. Skalli
Arts et Métiers Paris Tech, Laboratoire de Biomécanique (LBM) , 151 boulevard de l'hôpital, 75013 , Paris , France
3 shared publicationsJ.D. Laredo
Laboratoire de Radiologie Expérimentale , CNRS UMR 7052 Faculté de Médecine, Université Paris VII et Service de Radiologie de l'Hôpital Lariboisière , AP-HP, Paris, France
2 shared publicationsA. Serrurier
Arts et Métiers Paris Tech, Laboratoire de Biomécanique (LBM) , 151 boulevard de l'hôpital, 75013 , Paris , France
1 shared publicationB. Sandoz
Arts et Metiers ParisTech, CNRS, LBM
1 shared publicationD. Bonneau
Laboratoire de Biomécanique , ENSAM CER Paris , CNRS UMR8005, Paris, France
1 shared publicationD. Mitton
Arts et Metiers ParisTech, CNRS, LBM
1 shared publication
Latest Publications
- 24 August 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (sup1) , 231-232
A tibia model database from CT scan
- 24 August 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (sup1) , 231-232
A tibia model database from CT scan
- 23 April 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (8) , 821-828
Fast 3D reconstruction of the rib cage from biplanar radiographs
The stereoradiographic reconstruction method allows obtaining the three-dimensional (3D) rib cage geometry, which is essential for clinical evaluation or biomechanical studies. However, reconstruction time is still high (about 20 min considering operator time). The purpose of this study is to propose a 3D reconstruction of the rib cage from biplanar radiographs, based on the deformation of a prepersonalized object. Validation in comparison with computed tomography (CT-scan) acquisitions was performed. Local parameters (rib length, cord length, maximum width, area, and rib orientations) were computed from reconstructions. Parameters’ reproducibility was assessed with two observers and two measurements for 15 subjects. Regarding validation of the parameters, the mean difference with the CT-scan was between 6.3 and 1.3%. Observer variability was maximal for rib area (6.2%) and was lower than 4.2% for others parameters. The proposed reconstruction method reduced time (less than three minutes for operator time) to obtain a 3D reconstruction of the rib cage.
- 23 April 2010
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 48 (8) , 821-828
Fast 3D reconstruction of the rib cage from biplanar radiographs
The stereoradiographic reconstruction method allows obtaining the three-dimensional (3D) rib cage geometry, which is essential for clinical evaluation or biomechanical studies. However, reconstruction time is still high (about 20 min considering operator time). The purpose of this study is to propose a 3D reconstruction of the rib cage from biplanar radiographs, based on the deformation of a prepersonalized object. Validation in comparison with computed tomography (CT-scan) acquisitions was performed. Local parameters (rib length, cord length, maximum width, area, and rib orientations) were computed from reconstructions. Parameters’ reproducibility was assessed with two observers and two measurements for 15 subjects. Regarding validation of the parameters, the mean difference with the CT-scan was between 6.3 and 1.3%. Observer variability was maximal for rib area (6.2%) and was lower than 4.2% for others parameters. The proposed reconstruction method reduced time (less than three minutes for operator time) to obtain a 3D reconstruction of the rib cage.
- 5 June 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (3) , 281-290
Volumic patient-specific reconstruction of muscular system based on a reduced dataset of medical images
Three-dimensional mechanical modelling of muscles is essential for various biomechanical applications and clinical evaluation, but it requires a tedious manual processing of numerous images. A muscle reconstruction method is presented based on a reduced set of images to generate an approximate parametric object from basic dimensions of muscle contours. A regular volumic mesh is constructed based on this parametric object. The approximate object and the corresponding mesh are deformed to fit the exact muscles contours yielding patient-specific geometry. Evaluation was performed by comparison of geometry to that obtained by contouring all computed tomography (CT) slices, and by quantification of the mesh quality criteria. Muscle fatty infiltration was estimated using a threshold between fat and muscle. Volumic fat index (VFI) of a muscle was computed using first all the complete CT scan slices containing the muscle (VFIref) and a second time only the slices used for reconstruction (VFIrecons). Mean volume error estimation was 2.6% and hexahedron meshes fulfilled quality criteria. VFIrecons respect the individual variation of fat content.
- 5 June 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (3) , 281-290
Volumic patient-specific reconstruction of muscular system based on a reduced dataset of medical images
Three-dimensional mechanical modelling of muscles is essential for various biomechanical applications and clinical evaluation, but it requires a tedious manual processing of numerous images. A muscle reconstruction method is presented based on a reduced set of images to generate an approximate parametric object from basic dimensions of muscle contours. A regular volumic mesh is constructed based on this parametric object. The approximate object and the corresponding mesh are deformed to fit the exact muscles contours yielding patient-specific geometry. Evaluation was performed by comparison of geometry to that obtained by contouring all computed tomography (CT) slices, and by quantification of the mesh quality criteria. Muscle fatty infiltration was estimated using a threshold between fat and muscle. Volumic fat index (VFI) of a muscle was computed using first all the complete CT scan slices containing the muscle (VFIref) and a second time only the slices used for reconstruction (VFIrecons). Mean volume error estimation was 2.6% and hexahedron meshes fulfilled quality criteria. VFIrecons respect the individual variation of fat content.
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 125-126
Biomechanical modelling of hip and its soft tissue
(2008). Biomechanical modelling of hip and its soft tissue. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 11, Papers from the 33rd Congress of the Socit de Biomcanique,13rd September 2008, Universit de Technologie de Compigne, Centre Pierre Guillaumat, Compigne, France, pp. 125-126.
- 1 January 2008
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 11 (sup001) , 125-126
Biomechanical modelling of hip and its soft tissue
(2008). Biomechanical modelling of hip and its soft tissue. Computer Methods in Biomechanics and Biomedical Engineering: Vol. 11, Papers from the 33rd Congress of the Socit de Biomcanique,13rd September 2008, Universit de Technologie de Compigne, Centre Pierre Guillaumat, Compigne, France, pp. 125-126.