VDValérie Desauziers

Valérie Desauziers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Valérie Desauziers has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Pierre Mocho

    Laboratoire Thermique Energétique et Procédés, Université de Pau et des Pays de l'Adour, B.P. 1155, 64000, Pau, France

    3 shared publications
  • Virginie Larroque

    Laboratoire Génie de l’Environnement Industriel, Ecole des Mines d’Alès, Pau Cedex 9, France

    3 shared publications
  • Pierre Mocho

    Laboratoire Thermique Energétique et Procédés, Université de Pau et des Pays de l'Adour, BP 7511, 64075 Pau, France

    2 shared publications
  • François Lestremau

    Laboratoire Génie de l'Environnement Industriel, Ecole des Mines d'Alès, Hélioparc, 2 avenue Pierre Angot, 64053 Pau cedex, France

    1 shared publication
  • Jean Louis Fanlo

    Laboratoire Génie de l'Environnement Industriel, Ecole des Mines d'Alès, Hélioparc- 2, avenue Pierre Angot, 64053 Pau cedex, France

    1 shared publication
  • Jean-Louis Fanlo

    Ecole des Mines d’Alès

    1 shared publication

Latest Publications

  • Optimization of FLEC®-SPME for field passive sampling of VOCs emitted from solid building materials

    by Jérôme Nicolle, Valérie Desauziers, Pierre Mocho, Olivier Ramalho


  • Modelling of adsorption kinetics and calibration curves of gaseous volatile organic compounds with adsorptive solid-phase microextraction fibre: toluene and acetone for indoor air applications

    by Pierre Mocho, Jérôme Nicolle, Valérie Desauziers

    Solid-phase microextraction (SPME) with adsorptive Carboxen/PDMS fibre is a powerful sampling device for volatile organic compounds (VOCs) at trace levels in air. However, owing to competitive adsorption, quantification remains a challenging task. In this area, a theoretical model, based on Fick’s laws and an extended Langmuir equation, is proposed to deal with the adsorption kinetics of acetone/toluene mixture on SPME fibre under various static extraction conditions. The semipredictive model is first used to determine the axial diffusion coefficients of analytes in the sampling device. The model is then tested with a complex VOC mixture, showing good agreement with experimental data.


  • Comparison of two solid-phase microextraction methods for the quantitative analysis of VOCs in indoor air

    by Virginie Larroque, Valérie Desauziers, Pierre Mocho

    Competitive adsorption on adsorptive solid-phase microextraction (SPME) fibres implies careful determination of operating conditions for reliable quantitative analysis of VOCs in indoor air. With this objective, two analytical approaches, involving non-equilibrium and equilibrium extraction, were compared. The average detection limit obtained for GC-MS analysis of nine VOCs by the equilibrium method is 0.2 μg m−3, compared with 1.9 μg m−3 with the non-equilibrium method. The effect of the relative humidity of the air on the calibration plots was studied, and shown to affect acetone adsorption only. Hence, the concentrations that can be accurately determined are up to 9 μmol m−3. The methods were then applied to indoor air containing different concentrations of VOCs. The non-equilibrium method, involving short extraction time, can be used for detection of pollution peaks whereas equilibrium extraction is preferable for measurement of sub-μg m−3 ground concentration levels.


  • Development of a solid phase microextraction (SPME) method for the sampling of VOC traces in indoor air

    by Virginie Larroque, Valérie Desauziers, Pierre Mocho

    Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, α-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 μg m−3), they are all below 0.5 μg m−3. Calibration curves are linear up to 10 μmol m−3 for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.


  • Headspace SPME followed by GC/PFPD for the analysis of malodorous sulfur compounds in liquid industrial effluents

    by Jean-Louis Fanlo, François Lestremau, Valérie Desauziers

    Headspace SPME was used to analyse malodorous sulfur compounds in liquid industrial effluents. A pulsed flame photometric detector (PFPD) was selected for a specific and sensitive analysis. Two fibres, PDMS/Dvb and PDMS/Carboxen, which are particularly convenient for extracting small and volatile molecules were tested. To compare these fibres, both sensitivity and artefact formation were considered. The PDMS/Carboxen fibre showed the lower limits of detection and moreover the least artefact formation yields. It was therefore selected and headspace SPME extraction conditions were optimised. Limits of detection of the target compounds evaluated were 12–31 ng L−1 and repeatability was around 7%. Due to the adsorption mechanism involved, extraction is strongly influenced by the sample matrix and the low affinity compounds can suffer displacement effects. To investigate the occurrence of this phenomenon, two sampling times corresponding to non-equilibrium (5 min) and equilibrium conditions (60 min) were investigated. An external calibration was carried out by using standard solutions for both sampling times. The developed procedure was then compared to the standard addition method on a real industrial effluent. The results obtained from the two methods and for the two extraction times were in good agreement, demonstrating that even a long sampling time can be used. Therefore, the simple and timesaving external calibration was defined as relevant for an accurate quantification of sulfur compounds by headspace SPME.


  • A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres

    by Ludovic Tuduri, Valérie Desauziers, Jean Louis Fanlo

    Adsorptive solid-phase microextraction (SPME) fibres have proven to be a reliable means of sampling volatile organic compounds (VOCs) in air. In this work, polydimethylsiloxane/carboxen (PDMS/CAR) fibres were used to test a new approach of air sampling strategy with SPME in the lab which could lighten calibration procedure and enhance the use of this already rapid, simple, convenient and cost effective sampling technique. Indeed, only one curve can be used whatever the extraction time chosen by the analyst under constant conditions of air velocity and temperature. Ficks' law of diffusion was used to model SPME grab sampling when the fibre was totally exposed to the air sample. Experimental sampling rates were then determined by GC-FID for different sampling conditions, i.e. in a flowing air stream of known velocity (“dynamic mode”) and in a stagnant air (“static mode”). These sampling rates were found to be 3.50 and 17.80 mL min−1 for acetone, 4.06 and 21.20 mL min−1 for 1,2-dichloroethane, 5.10 and 27.80 mL min−1 for toluene and 5.36 and 30.80 mL min−1 for butyl acetate, for static and dynamic sampling modes respectively. Deviation from linearity of the calibration curves, indicating that a significant fraction of the adsorption sites are occupied, were determined. They were found to be approximately equal to 0.9, 1.57, 3.82 and 4.37 nmol for acetone, dichloroethane, toluene and butyl acetate, respectively. Experimentally determined sampling rates of these isolated compounds were also valid when a complex equimolar gaseous mixture was investigated, but deviation from linearity appears earlier. Then, for a given application, sampling times should be chosen very carefully to avoid competitive adsorption and hence, bad quantitative analysis results.