Luis H. Garcia-Rubio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luis H. Garcia-Rubio has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Catalina E. Alupoaei
Department of Chemical Engineering , University of South Florida , Tampa, Florida
2 shared publications- María-Teresa Celis
Lab. Polymers and Colloids (POLYCOL), Chemical Engineering, Universidad de Los Andes, Mérida, Venezuela
2 shared publications Alicia Garcia-Lopez
Univ. of South Florida (United States)
1 shared publicationAna Forgiarini
University of the Andes
1 shared publicationAndrés Gil
University of the Andes
1 shared publicationAngela Gennaccaro
Univ. of South Florida (United States)
1 shared publication
Latest Publications
- 25 September 2009
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 30 (9) , 1384-1389
Characterization of Monomer Emulsions in Terms of Droplet Size and Stability: Effect of Emulsifier Concentration
In emulsification processes, the estimation of the droplet size distribution is important data not only because it is linked with the manufacturing process, but also because it is an important parameter affecting the emulsion stability. The aim of this research is to use the ultraviolet-visible transmission spectrum as a tool for emulsion characterization (droplet size and stability) to be a function of monomer concentration, and to verify of emulsion stability using the volume of separated phase's technique. Both techniques are applied to monomer emulsions as a function of emulsifier concentration. Results show correlations between droplet size measurements and stability of emulsions using the spectroscopy technique; results were also found to be in agreement using the cleared volume method.
- 25 September 2009
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 30 (9) , 1384-1389
Characterization of Monomer Emulsions in Terms of Droplet Size and Stability: Effect of Emulsifier Concentration
In emulsification processes, the estimation of the droplet size distribution is important data not only because it is linked with the manufacturing process, but also because it is an important parameter affecting the emulsion stability. The aim of this research is to use the ultraviolet-visible transmission spectrum as a tool for emulsion characterization (droplet size and stability) to be a function of monomer concentration, and to verify of emulsion stability using the volume of separated phase's technique. Both techniques are applied to monomer emulsions as a function of emulsifier concentration. Results show correlations between droplet size measurements and stability of emulsions using the spectroscopy technique; results were also found to be in agreement using the cleared volume method.
- 1 January 2008
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 29 (1) , 20-26
Characterization of Emulsions: A Systematic Spectroscopy Study
Emulsification processes results in the generation of droplets populations produced from the dynamic equilibrium between the breakup and coalescence phenomena determined primarily by the formulation and composition variables, mixing characteristics and emulsion preparation. The information contained in the UV‐vis spectrum on the absorption and scattering properties of the emulsions lead to the interpretation of the spectra in terms of the particle size distribution, the particle shape, and the chemical composition of the oil and emulsifier. This article reports analysis of emulsions on transmission spectrum as function of the oil concentration and physicochemical variables. The quantitative interpretation of the transmission spectrum is performed in the portion where no absorption is present (300–820 nm) leading to reliable estimated of droplet size populations in the range of 1 to 20 µm. The possibility of obtaining information from a single multiwavelength measurement makes UV‐vis spectroscopy a powerful tool for characterization of dispersed systems.
- 1 January 2008
- Published by Taylor & Francis in Journal of Dispersion Science and Technology
- Vol. 29 (1) , 20-26
Characterization of Emulsions: A Systematic Spectroscopy Study
Emulsification processes results in the generation of droplets populations produced from the dynamic equilibrium between the breakup and coalescence phenomena determined primarily by the formulation and composition variables, mixing characteristics and emulsion preparation. The information contained in the UV‐vis spectrum on the absorption and scattering properties of the emulsions lead to the interpretation of the spectra in terms of the particle size distribution, the particle shape, and the chemical composition of the oil and emulsifier. This article reports analysis of emulsions on transmission spectrum as function of the oil concentration and physicochemical variables. The quantitative interpretation of the transmission spectrum is performed in the portion where no absorption is present (300–820 nm) leading to reliable estimated of droplet size populations in the range of 1 to 20 µm. The possibility of obtaining information from a single multiwavelength measurement makes UV‐vis spectroscopy a powerful tool for characterization of dispersed systems.
- 1 January 2005
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 192 (2) , 198-218
An Interpretation Model For The UV-VIS Spectra Of Microorganisms
Multiwavelength UV-vis spectra of microorganisms and cell suspensions contain quantitative information on their properties such as number, size, shape, chemical composition, and internal structure. These properties are essential for the identification and classification of cells. The complexity of microorganisms in terms of their chemical composition and internal structure makes the interpretation of their spectral signature a difficult task. In this article a model is proposed for the interpretation of the multiwavelength spectra of microorganisms. The proposed interpretation model is based on light scattering theory, spectral deconvolution techniques, and the approximation of the frequency-dependent optical properties of the basic constituents of living organisms. The optical properties as functions of wavelength and available literature data on the size and chemical composition of E. coli cells and Bacillus globigii spores were used to explore the sensitivity of the calculated spectra to the model parameters. It is shown that the proposed model can reproduce the features of experimentally measured spectra. The sensitivity of the spectra to the model parameters suggests that the proposed model can be used for the quantitative deconvolution of the UV-vis spectra in terms of critical information necessary for the detection and identification of microorganisms.
- 1 January 2005
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 192 (2) , 198-218
An Interpretation Model For The UV-VIS Spectra Of Microorganisms
Multiwavelength UV-vis spectra of microorganisms and cell suspensions contain quantitative information on their properties such as number, size, shape, chemical composition, and internal structure. These properties are essential for the identification and classification of cells. The complexity of microorganisms in terms of their chemical composition and internal structure makes the interpretation of their spectral signature a difficult task. In this article a model is proposed for the interpretation of the multiwavelength spectra of microorganisms. The proposed interpretation model is based on light scattering theory, spectral deconvolution techniques, and the approximation of the frequency-dependent optical properties of the basic constituents of living organisms. The optical properties as functions of wavelength and available literature data on the size and chemical composition of E. coli cells and Bacillus globigii spores were used to explore the sensitivity of the calculated spectra to the model parameters. It is shown that the proposed model can reproduce the features of experimentally measured spectra. The sensitivity of the spectra to the model parameters suggests that the proposed model can be used for the quantitative deconvolution of the UV-vis spectra in terms of critical information necessary for the detection and identification of microorganisms.
- 16 December 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5585, 88-98
A new spectroscopy method for in situ rapid detection and classification of micro-organisms
Recent developments in the characterization of particle dispersions have demonstrated that complementary information on the joint particle property distribution (size-shape-chemical composition) of micron and sub-micron particles is available from multiwavelength spectrophotometric measurements. The UV-VIS transmission spectra of the microorganism suspensions reported herein were recorded using a Hewlett-Packard 8453 diode array spectrometer with an acceptance angle smaller than 2 degrees. To eliminate concentration and particle number effects, the transmission spectra were normalized with the average optical density between 230-900 nm. Experimental results demonstrate that microorganisms at various states of growth give rise to spectral differences that can be used for their identification and classification and that this technology can be used for the characterization of the joint particle property distribution for a large variety of continuous, on-line, and in-situ particle characterization applications. An interpretation model has been developed for the quantitative interpretation of spectral patterns resulting from transmission measurements of microorganism suspensions. The interpretation model is based on light scattering theory and spectral deconvolution techniques and yields the quantitative information necessary to define the probability of the detection and identification of microorganisms. A data base of 54 pathogens has been created and demonstrates that the technology can be used in the field for real-time in-situ monitoring applications.
- 16 December 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5585, 88-98
A new spectroscopy method for in situ rapid detection and classification of micro-organisms
Recent developments in the characterization of particle dispersions have demonstrated that complementary information on the joint particle property distribution (size-shape-chemical composition) of micron and sub-micron particles is available from multiwavelength spectrophotometric measurements. The UV-VIS transmission spectra of the microorganism suspensions reported herein were recorded using a Hewlett-Packard 8453 diode array spectrometer with an acceptance angle smaller than 2 degrees. To eliminate concentration and particle number effects, the transmission spectra were normalized with the average optical density between 230-900 nm. Experimental results demonstrate that microorganisms at various states of growth give rise to spectral differences that can be used for their identification and classification and that this technology can be used for the characterization of the joint particle property distribution for a large variety of continuous, on-line, and in-situ particle characterization applications. An interpretation model has been developed for the quantitative interpretation of spectral patterns resulting from transmission measurements of microorganism suspensions. The interpretation model is based on light scattering theory and spectral deconvolution techniques and yields the quantitative information necessary to define the probability of the detection and identification of microorganisms. A data base of 54 pathogens has been created and demonstrates that the technology can be used in the field for real-time in-situ monitoring applications.
- 14 October 2003
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 19 (8) , 893-903
Quantitative spectroscopy analysis of prokaryotic cells: vegetative cells and spores
- 14 October 2003
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 19 (8) , 893-903
Quantitative spectroscopy analysis of prokaryotic cells: vegetative cells and spores