Cemil Sungur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cemil Sungur has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Ender Kaya
Agricultural Engineer, Rural Development Coordinator, Konya 42250, Turkey
1 shared publicationHalil Özkan
Natural and Applied Sciences, Selçuk University, Konya, Turkey
1 shared publicationSedat Çalişir
Professor, S.U. Agricultural Faculty Department of Agricultural Machinery and Technology Engineering, Konya 42250, Turkey
1 shared publication
Latest Publications
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 142 (11)
Developing an Automation System for Improving the Energy Efficiency of Constant Pressure Irrigation Pumps
In the present study, the changes in system efficiency were investigated at constant pressure and at different flow rates between 100 and 50% of the nominal flow rate in an irrigation pumping plant. For this purpose, programable logic controller (PLC) and human machine interface (HMI) panel software was developed to automatically control motor speed by means of frequency, and valve opening by means of servomotor in an irrigation pumping system. In this automation system, pump flow rate was measured using an electromagnetic flowmeter and pump discharge pressure was measured using a pressure sensor. According to the results of the study, optimum system efficiency was observed at the point corresponding to 70% of the nominal flow rate. This system efficiency value was found to be 6.9% higher than the nominal system efficiency. However, the system efficiency at points corresponding to 50% or lower ratios of the nominal flow rate was found to be lower than the nominal system efficiency.
- 1 November 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Irrigation and Drainage Engineering
- Vol. 142 (11)
Developing an Automation System for Improving the Energy Efficiency of Constant Pressure Irrigation Pumps
In the present study, the changes in system efficiency were investigated at constant pressure and at different flow rates between 100 and 50% of the nominal flow rate in an irrigation pumping plant. For this purpose, programable logic controller (PLC) and human machine interface (HMI) panel software was developed to automatically control motor speed by means of frequency, and valve opening by means of servomotor in an irrigation pumping system. In this automation system, pump flow rate was measured using an electromagnetic flowmeter and pump discharge pressure was measured using a pressure sensor. According to the results of the study, optimum system efficiency was observed at the point corresponding to 70% of the nominal flow rate. This system efficiency value was found to be 6.9% higher than the nominal system efficiency. However, the system efficiency at points corresponding to 50% or lower ratios of the nominal flow rate was found to be lower than the nominal system efficiency.
- 19 December 2014
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 95 (14) , 2850-2857
A real time quality control application for animal production by image processing
BACKGROUND: Standards of hygiene and health are of major importance in food production, and quality control has become obligatory in this field. Thanks to rapidly developing technologies, it is now possible for automatic and safe quality control of food production. For this purpose, image‐processing‐based quality control systems used in industrial applications are being employed to analyze the quality of food products. In this study, quality control of chicken (Gallus domesticus) eggs was achieved using a real time image‐processing technique.RESULTS: In order to execute the quality control processes, a conveying mechanism was used. Eggs passing on a conveyor belt were continuously photographed in real time by cameras located above the belt. The images obtained were processed by various methods and techniques. Using digital instrumentation, the volume of the eggs was measured, broken/cracked eggs were separated and dirty eggs were determined. In accordance with international standards for classifying the quality of eggs, the class of separated eggs was determined through a fuzzy implication model.CONCLUSION: According to tests carried out on thousands of eggs, a quality control process with an accuracy of 98% was possible. © 2014 Society of Chemical Industry
- 19 December 2014
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 95 (14) , 2850-2857
A real time quality control application for animal production by image processing
BACKGROUND: Standards of hygiene and health are of major importance in food production, and quality control has become obligatory in this field. Thanks to rapidly developing technologies, it is now possible for automatic and safe quality control of food production. For this purpose, image‐processing‐based quality control systems used in industrial applications are being employed to analyze the quality of food products. In this study, quality control of chicken (Gallus domesticus) eggs was achieved using a real time image‐processing technique.RESULTS: In order to execute the quality control processes, a conveying mechanism was used. Eggs passing on a conveyor belt were continuously photographed in real time by cameras located above the belt. The images obtained were processed by various methods and techniques. Using digital instrumentation, the volume of the eggs was measured, broken/cracked eggs were separated and dirty eggs were determined. In accordance with international standards for classifying the quality of eggs, the class of separated eggs was determined through a fuzzy implication model.CONCLUSION: According to tests carried out on thousands of eggs, a quality control process with an accuracy of 98% was possible. © 2014 Society of Chemical Industry
- 13 November 2007
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 4 (6) , 635-643
Sun-Tracking System with PLC Control for Photo-Voltaic Panels
In this study, the electromechanical control system of a photovoltaic (PV) panel tracking the sun on the axis it moves along according to its azimuthal angle was designed and implemented. In this system, Programmable Logic Controls (PLC) were used instead of photosensors, which are widely used for tracking the sun. The azimuthal angle of the sun from sunrise to sunset times was calculated for each day of the year at 37.6 degrees latitude in the Northern hemisphere, the location of the city where the experiment was conducted. According to this azimuth angle, the required analog signal was taken from the PLC analog module and sent to the actuator motor, which controlled the position of the panel to ensure that the rays fall vertically on the panel. After the mechanical control system of the system was started, the performance measurements of the solar panel were carried out. For this, the necessary measurements were implemented when the solar panel was in a fixed position. Afterwards, the panel was moved on a single axis according to the azimuthal angle and the necessary measurements were performed. The values obtained from the measurements were compared and the necessary evaluations were conducted.
- 13 November 2007
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 4 (6) , 635-643
Sun-Tracking System with PLC Control for Photo-Voltaic Panels
In this study, the electromechanical control system of a photovoltaic (PV) panel tracking the sun on the axis it moves along according to its azimuthal angle was designed and implemented. In this system, Programmable Logic Controls (PLC) were used instead of photosensors, which are widely used for tracking the sun. The azimuthal angle of the sun from sunrise to sunset times was calculated for each day of the year at 37.6 degrees latitude in the Northern hemisphere, the location of the city where the experiment was conducted. According to this azimuth angle, the required analog signal was taken from the PLC analog module and sent to the actuator motor, which controlled the position of the panel to ensure that the rays fall vertically on the panel. After the mechanical control system of the system was started, the performance measurements of the solar panel were carried out. For this, the necessary measurements were implemented when the solar panel was in a fixed position. Afterwards, the panel was moved on a single axis according to the azimuthal angle and the necessary measurements were performed. The values obtained from the measurements were compared and the necessary evaluations were conducted.