GFGiuseppe Fratino

Giuseppe Fratino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Giuseppe Fratino has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prospective Study of Indwelling Central Venous Catheter-Related Complications in Children With Broviac or Clampless Valved Catheters

    by Giuseppe Fratino, Angelo C. Molinari, Cinzia Mazzola, Mareva Giacchino, Paola Saracco, Evelina Bertocchi, Elio Castagnola

    To compare two types of central venous catheters (Broviac and valved clampless) for the incidence and severity of catheter-related complications in children. The authors report data on the mechanical and infectious complications collected in a prospective analysis of 92 catheters inserted in 82 children from January 2000 to March 2001. Two different devices were inserted: 51 Broviac and 41 clampless valved catheters. During the follow-up of 17,803 catheter-days 52 complications were observed: 40 mechanical episodes and 12 infectious events. In the Broviac group the median follow-up was 179 days and the total number of catheter-days was 10,911. A total of 29 complications were observed, occurring in 22 catheters (43%), with an overall incidence of 0.27/100 catheter-days. In the clampless group the median follow-up was 134 days and the total number of catheter days was 6893. A total of 23 complications were observed, occurring in 19 devices (46%), with an incidence of 0.32/100 catheter days. There were no major differences in the incidence of mechanical or infectious complications between the two devices. Malfunction was more frequent in Broviac catheters, whereas catheter displacement occurred more frequently in clampless valved catheters. These results show the importance of central venous catheter-related mechanical complications in the management of children with hematologic or oncologic malignancies.


  • MECHANICAL COMPLICATIONS RELATED TO INDWELLING CENTRAL VENOUS CATHETER IN PEDIATRIC HEMATOLOGY/ONCOLOGY PATIENTS

    by Giuseppe Fratino, C. Mazzola, P. Buffa, M. Torre, E. Castagnola, P. Magillo, A. C. Molinari

    Indwelling central venous catheters (CVC) are essential devices in the management of children with oncologic/hematologic diseases or following bone marrow transplantation. The authors report data on the mechanical complications observed in pediatric hematology/oncology patients, collected by a retrospective analysis of clinical records of 482 patients in whom 567 indwelling central venous catheters had been inserted from January 1992 to December 1998 at the G. Gaslini Institute. During the study period, 52 episodes of mechanical complications (9%) were observed: mechanical obstruction (24 episodes), catheter dislocation (13), problems related to catheter material (12), and accidental removal (3). In 25 cases removal and replacement of CVC was necessary for the treatment of complications, while medical treatment (thrombolytic-antithrombotic) was successful and well tolerated in 8. The study shows the importance of mechanical complications in children with indwelling CVC for hematologic or oncologic diseases. Moreover, the experience of administering a systemic low-dosage thrombolytic therapy demonstrates new prospects of reducing CVC replacement by restoring CVC viability.