CMClaire McLarnon

Claire McLarnon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Claire McLarnon has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Tom Davison

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    3 shared publications
  • Beverly Henderson

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    2 shared publications
  • Denise Leese

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    2 shared publications
  • Ian Johnson

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    2 shared publications
  • John Hill

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    2 shared publications
  • Suzanne Marley

    Newcastle BAHA Programme, ENT Department, Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne NE7 7DN, United Kingdom

    2 shared publications

Latest Publications

  • Evidence for Early Loading of Osseointegrated Implants for Bone Conduction at 4 Weeks

    by Claire Marie McLarnon, Ian Johnson, Tom Davison, John Hill, Beverly Henderson, Denise Leese, Suzanne Marley

    Introduction The purpose of our study was to directly measure the stability of the abutment using resonance frequency analysis (RFA) and to report on the change in stability over time for implants loaded 4 weeks postoperatively. Materials and Methods The principle behind RFA is to obtain a numerical value relating to stability. The Osstell RFA recording device measures the resonance in a magnetic field of a 1 cm commercially manufactured attachment (SmartPeg) that is screwed onto the bone conduction device abutment. RFA measurements were obtained at surgery, 1, 4, and 16 weeks after implant surgery. The degree of movement (vibration) is inversely proportional to the stability of the abutment, and a numerical figure, the implant stability quotient (ISQ), is derived. Patients were fitted with the new Cochlear Bone-Anchored Hearing Aid (BAHA) BI300 series implant using a 1-stage procedure and loaded 4 weeks postoperatively. Results Prospectively 68 consecutive patients were recruited with a male to female ratio of 23:45. Nineteen patients had bilateral BAHA devices fitted, giving a total of 88 implants. The average ISQ change (delta) for the cohort gives a value of 0 at time of surgery. The change in ISQ at 1 week was −0.10 (95% confidence interval [CI], 0.74), at 4 weeks was 1.21 (95% CI, 0.59), and at 16 weeks was 1.60 (95% CI, 0.77). Discussion Successful early loading of the BAHA sound processor has been achieved. RFA provides a reliable means of assessing stability for loading and measuring implant stability in the longer term. These data support the evidence for early loading at 4 weeks with good clinical safety.


  • Quality-of-life considerations in treatment of unresectable, recurrent head and neck cancer

    by Claire McLarnon, Praneta Kulloo, Hisham Mehanna, Charles Kelly, Vinidh Paleri

    (2010). Quality-of-life considerations in treatment of unresectable, recurrent head and neck cancer. Expert Review of Anticancer Therapy: Vol. 10, No. 3, pp. 345-352.


  • Bone‐Anchored Hearing Aid: Comparison of Benefit by Patient Subgroups

    by Claire M. McLarnon, Tom Davison, Ian J. M. Johnson

    Objectives/Hypothesis: The osseointegrated bone‐anchored hearing aid, using the Branemark system, is well established and has proven benefit. The aim was to study quality of life benefits within patient subgroups using the validated Glasgow Benefit Inventory (GBI).Study Design: Retrospective questionnaire study.Methods: Ninety‐four consecutive patients were enrolled into the study. Mean patient age was 49 years, with a female‐to‐male ratio of 1.1:1. Patient subgroups were discharging mastoid cavities, chronic active otitis media, congenital ear problems, otosclerosis, and acoustic neuroma and other unilateral hearing losses.Results: The response rate was 73%. The score for total benefit of bone‐anchored hearing aid fitting for the entire group was +33.3 (95% confidence interval [CI], 25–42). Glasgow Benefit Inventory scores for each subgroup were all greater than +20. The congenital atresia group scored highest with +45 (95% CI, 28–61). Variation in benefit across the subgroups has been demonstrated. Fitting of BAHA following acoustic neuroma surgery was shown to be of benefit with a score of +22.2. General benefits scored highest in all subgroups compared with physical and social benefits.Conclusion: The study demonstrated the differences in benefit within patient subgroups. Its results can be used to give patients a predictive value at the time of preoperative counseling. The study identified congenital ear disorders as the group likely to obtain maximal benefit. Notably, for the first time, the study demonstrated the documented benefit of restoring stereo hearing to patients who have acquired unilateral hearing loss following acoustic neuroma surgery using a BAHA.