Alan G. Joly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alan G. Joly has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth M. Beck
William R. Wiley Environmental Molecular Science Laboratory, Chemical and Materials Sciences Division, Pacific Northwest National Laboratory, Richland, USA
2 shared publications - Wayne P. Hess
Pacific Northwest National Laboratory , P.O. Box 999, Richland, Washington 99352, USA
2 shared publications - Gang Xiong
Department of Physics, Wake Forest University, Winston‐Salem, NC 27109
1 shared publication - John M. White
The University of Texas at Austin Center for Materials Chemistry, Department of Chemistry and Biochemistry Austin, Texas 78712
1 shared publication - Yangming Sun
Microelectronics Research Center, Laboratory for Interconnect and Packaging, Pickle Research Campus, The University of Texas at Austin, Austin, TX, 78758, United States
1 shared publication
Latest Publications
- 1 September 2009
- Published by Elsevier in Applied Surface Science
- Vol. 255 (24) , 9562-9565
Two-color laser desorption of nanostructured MgO thin films
- 1 September 2009
- Published by Elsevier in Applied Surface Science
- Vol. 255 (24) , 9562-9565
Two-color laser desorption of nanostructured MgO thin films
- 1 January 2006
- Published by Springer Nature in MRS Proceedings
- Vol. 914
Real Time Study of Cu Diffusion through a Ru Thin Film by Photoemission Electron Microscopy (PEEM)
We demonstrate the efficacy of Photoemission Electron Microscopy (PEEM) as a tool to detect metal diffusion processes at nanoscale spatial resolution in real time. For a sample comprising a nominally 1 nm physical vapor-deposited (PVD) Ru thin film covering a thick Cu substrate, we have observed the appearance of bright features on a dark background as the temperature is monotonically increased and irradiated with photons from a Hg arc lamp. These bright features are the result of a lower work function due to Cu diffusion through the Ru film.
- 1 January 2006
- Published by Springer Nature in MRS Proceedings
- Vol. 914
Real Time Study of Cu Diffusion through a Ru Thin Film by Photoemission Electron Microscopy (PEEM)
We demonstrate the efficacy of Photoemission Electron Microscopy (PEEM) as a tool to detect metal diffusion processes at nanoscale spatial resolution in real time. For a sample comprising a nominally 1 nm physical vapor-deposited (PVD) Ru thin film covering a thick Cu substrate, we have observed the appearance of bright features on a dark background as the temperature is monotonically increased and irradiated with photons from a Hg arc lamp. These bright features are the result of a lower work function due to Cu diffusion through the Ru film.