Mike B. Dixon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mike B. Dixon has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Christopher W. K. Chow
Sustainable Infrastructure and Resource Management (SIRM), UniSA STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
4 shared publications B. K. O'Neill
School of Chemical Engineering, The University of Adelaide, SA, 5005, Australia
2 shared publicationsG. Newcombe
Australian Water Quality Centre, SA Water Corporation, GPO Box 1751, Adelaide, SA, 5001, Australia
2 shared publicationsGayle Newcombe
2 shared publicationsL. Ho
Australian Water Quality Centre, SA Water Corporation, GPO Box 1751, Adelaide, SA, 5001, Australia
2 shared publicationsLionel Ho
2 shared publications
Latest Publications
- Open Access
- 1 January 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (1-3) , 397-406
Experiences from the Adelaide Desalination project: ultrafiltration cleaning optimisation—from pilot to full-scale operation
Membrane fouling remains a major concern for ultrafiltration (UF) pretreatment for seawater reverse osmosis (RO). The focus of this study was the optimisation of the chemical cleaning regime and any associated impact on the downstream cartridge filters (pre-RO). Different shock acidification/chlorination and maintenance wash (MW) regimes for the pilot UF were tested. The results of the study at the Adelaide Desalination Pilot Plant (ADPP) are summarised as follows:
- 1 January 2013
- Published by Elsevier in Desalination and Water Treatment
- Vol. 51 (1-3) , 397-406
Open AccessExperiences from the Adelaide Desalination project: ultrafiltration cleaning optimisation—from pilot to full-scale operation
Membrane fouling remains a major concern for ultrafiltration (UF) pretreatment for seawater reverse osmosis (RO). The focus of this study was the optimisation of the chemical cleaning regime and any associated impact on the downstream cartridge filters (pre-RO). Different shock acidification/chlorination and maintenance wash (MW) regimes for the pilot UF were tested. The results of the study at the Adelaide Desalination Pilot Plant (ADPP) are summarised as follows:
- Open Access
- 1 April 2011
- Published by IWA Publishing in Water Science & Technology
- Vol. 63 (7) , 1405-1411
Integrated membrane systems incorporating coagulation, activated carbon and ultrafiltration for the removal of toxic cyanobacterial metabolites from Anabaena circinalis
The use of integrated membrane systems (a train of treatment processes incorporating one or more membranes) is increasing globally as the technology is very effective for the production of high quality drinking water. In this investigation a laboratory scale integrated membrane system (IMS) featuring coagulation, powdered activated carbon (PAC) and ultrafiltration (UF) was investigated for the removal of an Australian strain of the cyanobacteria Anabaena circinalis and the cyanotoxin it produced. Three coagulants were compared, aluminium chlorohydrate (ACH), aluminium sulphate (alum) and an engineered aluminium coagulant referred to as high performance aluminium chlorohydrate (HPAC). PAC (Acticarb PS1000) was tested to determine adsorption of extracellular saxitoxin. Removal of A. circinalis cells was 100% by UF alone and the removal of cells prior to the membrane by coagulation reduced fouling attributed to algogenic organic material. Alum was the least efficient coagulant for removal of cells while ACH and HPAC were similar. Saxitoxin removal reached a maximum of 80% using ACH and PAC. The UF-IMS was challenged using a natural bloom of A. circinalis that occurred in the Myponga Reservoir in South Australia.
- 1 April 2011
- Published by IWA Publishing in Water Science & Technology
- Vol. 63 (7) , 1405-1411
Open AccessIntegrated membrane systems incorporating coagulation, activated carbon and ultrafiltration for the removal of toxic cyanobacterial metabolites from Anabaena circinalis
The use of integrated membrane systems (a train of treatment processes incorporating one or more membranes) is increasing globally as the technology is very effective for the production of high quality drinking water. In this investigation a laboratory scale integrated membrane system (IMS) featuring coagulation, powdered activated carbon (PAC) and ultrafiltration (UF) was investigated for the removal of an Australian strain of the cyanobacteria Anabaena circinalis and the cyanotoxin it produced. Three coagulants were compared, aluminium chlorohydrate (ACH), aluminium sulphate (alum) and an engineered aluminium coagulant referred to as high performance aluminium chlorohydrate (HPAC). PAC (Acticarb PS1000) was tested to determine adsorption of extracellular saxitoxin. Removal of A. circinalis cells was 100% by UF alone and the removal of cells prior to the membrane by coagulation reduced fouling attributed to algogenic organic material. Alum was the least efficient coagulant for removal of cells while ACH and HPAC were similar. Saxitoxin removal reached a maximum of 80% using ACH and PAC. The UF-IMS was challenged using a natural bloom of A. circinalis that occurred in the Myponga Reservoir in South Australia.
- 1 April 2011
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 188 (1-3) , 288-295
Removal of cyanobacterial metabolites by nanofiltration from two treated waters
- 1 April 2011
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 188 (1-3) , 288-295
Removal of cyanobacterial metabolites by nanofiltration from two treated waters
- 1 February 2011
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 186 (2-3) , 1553-1559
A coagulation–powdered activated carbon–ultrafiltration – Multiple barrier approach for removing toxins from two Australian cyanobacterial blooms
- 1 February 2011
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 186 (2-3) , 1553-1559
A coagulation–powdered activated carbon–ultrafiltration – Multiple barrier approach for removing toxins from two Australian cyanobacterial blooms
- Open Access
- 1 March 2010
- Published by IWA Publishing in Water Science & Technology
- Vol. 61 (5) , 1189-1199
Nanofiltration for the removal of algal metabolites and the effects of fouling
Nanofiltration (NF) has been shown to be an effective way of removing organic micropollutants from drinking water due to its size exclusion properties. A rapid bench scale membrane test unit was utilised to trial six NF membranes to remove the algal metabolites, microcystin, cylindrospermopsin, 2-methylisoborneol (MIB) and geosmin (GSM). Membrane fouling due to the algal metabolites was observed for both charged and neutral metabolites. MIB and GSM were removed effectively by low molecular weight cut-off (MWCO) membranes but less effectively by a higher MWCO membrane. Removal of MIB and GSM by the higher MWCO membrane was improved as the membrane fouled. Microcystin was initially removed to above 90% by tight NF membranes but fouling of several membranes caused decreased percent removals over time. Tight NF membranes afforded removals of 90–100% for cylindrospermopsin, while removal by the higher MWCO membrane was lower but improved with time due to fouling.
- 1 March 2010
- Published by IWA Publishing in Water Science & Technology
- Vol. 61 (5) , 1189-1199
Open AccessNanofiltration for the removal of algal metabolites and the effects of fouling
Nanofiltration (NF) has been shown to be an effective way of removing organic micropollutants from drinking water due to its size exclusion properties. A rapid bench scale membrane test unit was utilised to trial six NF membranes to remove the algal metabolites, microcystin, cylindrospermopsin, 2-methylisoborneol (MIB) and geosmin (GSM). Membrane fouling due to the algal metabolites was observed for both charged and neutral metabolites. MIB and GSM were removed effectively by low molecular weight cut-off (MWCO) membranes but less effectively by a higher MWCO membrane. Removal of MIB and GSM by the higher MWCO membrane was improved as the membrane fouled. Microcystin was initially removed to above 90% by tight NF membranes but fouling of several membranes caused decreased percent removals over time. Tight NF membranes afforded removals of 90–100% for cylindrospermopsin, while removal by the higher MWCO membrane was lower but improved with time due to fouling.
- 1 March 2010
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 59 (2-3) , 92-99
Extending membrane longevity by using MIEX as a pre-treatment
The use of membrane technology and in particular microfiltration (MF) is becoming more popular as a water treatment technology. The operational lifetime of MF membranes can be reduced by natural organic matter (NOM) which is a known foulant. The MIEX DOC (Magnetic Ion EXchange for Dissolved Organic Carbon removal) process was developed to remove NOM from raw water sources. It was anticipated that a reduction in NOM resulting from the MIEX DOC process would also improve the performance of MF systems. A pilot plant study was undertaken to directly measure the impact of MIEX pre-treatment on MF performance. A long term study with a regular cleaning strategy revealed little benefit in MIEX pre-treatment to improve the lifetime of the MF membrane. However, by applying less frequent cleaning it was immediately apparent that fouling was occurring at a faster rate without MIEX pre-treatment. Further studies showed that irreversible fouling also occurred at a faster rate on the membrane without pre-treatment.M. B. Dixon, J. Y. Morran and M. Drika
- 1 March 2010
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 59 (2-3) , 92-99
Extending membrane longevity by using MIEX as a pre-treatment
The use of membrane technology and in particular microfiltration (MF) is becoming more popular as a water treatment technology. The operational lifetime of MF membranes can be reduced by natural organic matter (NOM) which is a known foulant. The MIEX DOC (Magnetic Ion EXchange for Dissolved Organic Carbon removal) process was developed to remove NOM from raw water sources. It was anticipated that a reduction in NOM resulting from the MIEX DOC process would also improve the performance of MF systems. A pilot plant study was undertaken to directly measure the impact of MIEX pre-treatment on MF performance. A long term study with a regular cleaning strategy revealed little benefit in MIEX pre-treatment to improve the lifetime of the MF membrane. However, by applying less frequent cleaning it was immediately apparent that fouling was occurring at a faster rate without MIEX pre-treatment. Further studies showed that irreversible fouling also occurred at a faster rate on the membrane without pre-treatment.M. B. Dixon, J. Y. Morran and M. Drika