Ulrike Schmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ulrike Schmidt has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Stefan Pollak
9 shared publicationsMarkus Grosse Perdekamp
Institut für Rechtsmedizin, Universität Freiburg
3 shared publicationsJana Naue
Institute of Legal Medicine, Freiburg University Medical Center, Albertstr. 9, 79104, Freiburg, Germany
2 shared publicationsLara Jungmann
2 shared publicationsThomas Zacher
2 shared publicationsTimo Sänger
2 shared publications
Latest Publications
- Open Access
- 20 November 2025
- Published by Elsevier in Forensic Science International
- Vol. 378, 112729
Evaluative sub-source and activity level reporting in Austria, Germany and Switzerland
- 20 November 2025
- Published by Elsevier in Forensic Science International
- Vol. 378, 112729
Open AccessEvaluative sub-source and activity level reporting in Austria, Germany and Switzerland
- 14 March 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 130 (5) , 1181-1184
Detection of a G>C single nucleotide polymorphism within a repetitive DNA sequence by high-resolution DNA melting
In standard forensic DNA analysis, single base mutations within short tandem repeats (STR) mostly escape detection. In this study, high-resolution DNA melting (HRM) is compared to minisequencing and Sanger sequencing as to determine the most suitable method for detection of a G to C mutation within a repetitive DNA sequence, the STR system DXS10161. It shows an ATG/ATC polymorphism surrounded by a variable number of (TATC) and (ATCT) motifs. Neutral base changes like G:C to C:G result in very low differences in the melting temperature (T m) of the PCR amplicons. By enhanced resolution of fluorescence vs. temperature in HRM, the technique showed to be suitable for detecting a G to C transversion in this repetitive DNA sequence context. Compared to minisequencing, HRM is more time- and cost-effective. Results were confirmed by Sanger sequencing.
- 14 March 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 130 (5) , 1181-1184
Detection of a G>C single nucleotide polymorphism within a repetitive DNA sequence by high-resolution DNA melting
In standard forensic DNA analysis, single base mutations within short tandem repeats (STR) mostly escape detection. In this study, high-resolution DNA melting (HRM) is compared to minisequencing and Sanger sequencing as to determine the most suitable method for detection of a G to C mutation within a repetitive DNA sequence, the STR system DXS10161. It shows an ATG/ATC polymorphism surrounded by a variable number of (TATC) and (ATCT) motifs. Neutral base changes like G:C to C:G result in very low differences in the melting temperature (T m) of the PCR amplicons. By enhanced resolution of fluorescence vs. temperature in HRM, the technique showed to be suitable for detecting a G to C transversion in this repetitive DNA sequence context. Compared to minisequencing, HRM is more time- and cost-effective. Results were confirmed by Sanger sequencing.
- Open Access
- 6 July 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (7) , e0131845
Automated Forensic Animal Family Identification by Nested PCR and Melt Curve Analysis on an Off-the-Shelf Thermocycler Augmented with a Centrifugal Microfluidic Disk Segment
Nested PCR remains a labor-intensive and error-prone biomolecular analysis. Laboratory workflow automation by precise control of minute liquid volumes in centrifugal microfluidic Lab-on-a-Chip systems holds great potential for such applications. However, the majority of these systems require costly custom-made processing devices. Our idea is to augment a standard laboratory device, here a centrifugal real-time PCR thermocycler, with inbuilt liquid handling capabilities for automation. We have developed a microfluidic disk segment enabling an automated nested real-time PCR assay for identification of common European animal groups adapted to forensic standards. For the first time we utilize a novel combination of fluidic elements, including pre-storage of reagents, to automate the assay at constant rotational frequency of an off-the-shelf thermocycler. It provides a universal duplex pre-amplification of short fragments of the mitochondrial 12S rRNA and cytochrome b genes, animal-group-specific main-amplifications, and melting curve analysis for differentiation. The system was characterized with respect to assay sensitivity, specificity, risk of cross-contamination, and detection of minor components in mixtures. 92.2% of the performed tests were recognized as fluidically failure-free sample handling and used for evaluation. Altogether, augmentation of the standard real-time thermocycler with a self-contained centrifugal microfluidic disk segment resulted in an accelerated and automated analysis reducing hands-on time, and circumventing the risk of contamination associated with regular nested PCR protocols.
- 6 July 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (7) , e0131845
Open AccessAutomated Forensic Animal Family Identification by Nested PCR and Melt Curve Analysis on an Off-the-Shelf Thermocycler Augmented with a Centrifugal Microfluidic Disk Segment
Nested PCR remains a labor-intensive and error-prone biomolecular analysis. Laboratory workflow automation by precise control of minute liquid volumes in centrifugal microfluidic Lab-on-a-Chip systems holds great potential for such applications. However, the majority of these systems require costly custom-made processing devices. Our idea is to augment a standard laboratory device, here a centrifugal real-time PCR thermocycler, with inbuilt liquid handling capabilities for automation. We have developed a microfluidic disk segment enabling an automated nested real-time PCR assay for identification of common European animal groups adapted to forensic standards. For the first time we utilize a novel combination of fluidic elements, including pre-storage of reagents, to automate the assay at constant rotational frequency of an off-the-shelf thermocycler. It provides a universal duplex pre-amplification of short fragments of the mitochondrial 12S rRNA and cytochrome b genes, animal-group-specific main-amplifications, and melting curve analysis for differentiation. The system was characterized with respect to assay sensitivity, specificity, risk of cross-contamination, and detection of minor components in mixtures. 92.2% of the performed tests were recognized as fluidically failure-free sample handling and used for evaluation. Altogether, augmentation of the standard real-time thermocycler with a self-contained centrifugal microfluidic disk segment resulted in an accelerated and automated analysis reducing hands-on time, and circumventing the risk of contamination associated with regular nested PCR protocols.
- 1 January 2013
- Published by Elsevier in Forensic Science International
- Vol. 224 (1) , 33-36
Modification of hematoma findings in the breast region
- 1 January 2013
- Published by Elsevier in Forensic Science International
- Vol. 224 (1) , 33-36
Modification of hematoma findings in the breast region
- 4 July 2012
- Published by Springer Nature in Rechtsmedizin
- Vol. 22 (4) , 237-243
DNA-Quantifizierung in der forensischen Spurenkunde
- 4 July 2012
- Published by Springer Nature in Rechtsmedizin
- Vol. 22 (4) , 237-243
DNA-Quantifizierung in der forensischen Spurenkunde
- 29 June 2012
- Published by Springer Nature in Rechtsmedizin
- Vol. 22 (4) , 252-255
Epipleurales Hämatom
- 15 April 2011
- Published by Elsevier in Forensic Science International
- Vol. 207 (1-3) , e12-e15
Suicide of a cyclist
- 15 April 2011
- Published by Elsevier in Forensic Science International
- Vol. 207 (1-3) , e12-e15
Suicide of a cyclist
- 2 September 2010
- Vol. 226, 55-65
[Sudden/unexpected death due to spontaneous aortic rupture: two unusual manifestation forms].
Sudden unexpected death from a natural (pathological) cause often occurs under suspicious circumstances suggesting foreign intervention, so that a forensic autopsy is deemed necessary. In adults, a significant share of these deaths is due to spontaneous ruptures of the aorta. In figures, dissections of the ascending aorta and the aortic arch (mostly associated with secondary perforation into the pericardium) account for a large percentage followed by arteriosclerotic aneurysms of the abdominal aorta (with retroperitoneal and sometimes intraperitoneal hemorrhage). The authors report on two fatal aortic ruptures in which the hemorrhage showed an unusual route to spread. In the first case an 80-year-old man with an arteriosclerotic aneurysm of the abdominal aorta died from acute intestinal bleeding via an aortojejunal fistula. In a 42-year-old man, a dissecting hemorrhage in the wall of the aortic arch resulted in the compression of the branching sites of the brachiocephalic trunk, the left common carotid artery and the left subclavian artery, while the volume of blood in the pericardium was rather small (60 ml). On the basis of these examples, the medicolegal aspects of spontaneous aortic ruptures are discussed.
- 2 September 2010
- Vol. 226, 55-65
[Sudden/unexpected death due to spontaneous aortic rupture: two unusual manifestation forms].
Sudden unexpected death from a natural (pathological) cause often occurs under suspicious circumstances suggesting foreign intervention, so that a forensic autopsy is deemed necessary. In adults, a significant share of these deaths is due to spontaneous ruptures of the aorta. In figures, dissections of the ascending aorta and the aortic arch (mostly associated with secondary perforation into the pericardium) account for a large percentage followed by arteriosclerotic aneurysms of the abdominal aorta (with retroperitoneal and sometimes intraperitoneal hemorrhage). The authors report on two fatal aortic ruptures in which the hemorrhage showed an unusual route to spread. In the first case an 80-year-old man with an arteriosclerotic aneurysm of the abdominal aorta died from acute intestinal bleeding via an aortojejunal fistula. In a 42-year-old man, a dissecting hemorrhage in the wall of the aortic arch resulted in the compression of the branching sites of the brachiocephalic trunk, the left common carotid artery and the left subclavian artery, while the volume of blood in the pericardium was rather small (60 ml). On the basis of these examples, the medicolegal aspects of spontaneous aortic ruptures are discussed.
- 1 February 2010
- Published by Elsevier in Forensic Science International
- Vol. 195 (1-3) , 1-5
Sharp force injuries in “clinical” forensic medicine
- 1 February 2010
- Published by Elsevier in Forensic Science International
- Vol. 195 (1-3) , 1-5
Sharp force injuries in “clinical” forensic medicine
- 3 December 2008
- Vol. 222, 117-27
[DNA amplification on chemically structured chips in forensic STR analysis].
The present study deals with low-volume amplification of short tandem repeats (STRs) for forensic DNA analysis. A chemically structured chip in microscopic slide format was used to amplify standard forensic casework samples in a 1-microL reaction volume primarily with the well-known and widely used PowerPlex kit and with other commercially available STR kits. Tests regarding sensitivity, mixture analysis, robustness, reproducibility, buffer composition and technical performance were carried out to check the usefulness of this amplification strategy. The results obtained show that low-volume amplification is a promising option in the forensic DNA typing toolbox. Restrictions to this method, which are strictly related to the kit and the respective buffer used, were found in low copy number (LCN) DNA typing, mixture analysis and technical performance. Problematic typing results included artefact alleles, increase in locus and heterozygote imbalance, allelic and locus dropout as well as increase of stutters, especially when amplifying less than 200-300 pg of DNA. In contrast, convincing advantages are a higher sensitivity, better amplification efficiency and the low cost factor of this method.
- 3 December 2008
- Vol. 222, 117-27
[DNA amplification on chemically structured chips in forensic STR analysis].
The present study deals with low-volume amplification of short tandem repeats (STRs) for forensic DNA analysis. A chemically structured chip in microscopic slide format was used to amplify standard forensic casework samples in a 1-microL reaction volume primarily with the well-known and widely used PowerPlex kit and with other commercially available STR kits. Tests regarding sensitivity, mixture analysis, robustness, reproducibility, buffer composition and technical performance were carried out to check the usefulness of this amplification strategy. The results obtained show that low-volume amplification is a promising option in the forensic DNA typing toolbox. Restrictions to this method, which are strictly related to the kit and the respective buffer used, were found in low copy number (LCN) DNA typing, mixture analysis and technical performance. Problematic typing results included artefact alleles, increase in locus and heterozygote imbalance, allelic and locus dropout as well as increase of stutters, especially when amplifying less than 200-300 pg of DNA. In contrast, convincing advantages are a higher sensitivity, better amplification efficiency and the low cost factor of this method.