AJAdrienne M. Juett

Adrienne M. Juett

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adrienne M. Juett has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The X‐Ray Position and Optical Counterpart of the Accretion‐powered Millisecond Pulsar XTE J1814−338

    by Miriam I. Krauss, Zhongxiang Wang, Allyn Dullighan, Adrienne M. Juett, David L. Kaplan, Deepto Chakrabarty, Marten H. van Kerkwijk, Danny Steeghs, Peter G. Jonker, Craig B. Markwardt

    We report the precise optical and X-ray localization of the 3.2 ms accretion-powered X-ray pulsar XTE J1814-338 with data from the Chandra X-Ray Observatory as well as optical observations conducted during the 2003 June discovery outburst. Optical imaging of the field during the outburst of this soft X-ray transient reveals an R = 18 star at the X-ray position. This star is absent (R > 20) from an archival 1989 image of the field and brightened during the 2003 outburst, and we therefore identify it as the optical counterpart of XTE J1814-338. The best source position derived from optical astrometry is R.A. = 18h13m39.s04, Dec.= -33d46m22.3s (J2000). The featureless X-ray spectrum of the pulsar in outburst is best fit by an absorbed power-law (with photon index = 1.41 +- 0.06) plus blackbody (with kT = 0.95 +- 0.13 keV) model, where the blackbody component contributes approximately 10% of the source flux. The optical broad-band spectrum shows evidence for an excess of infrared emission with respect to an X-ray heated accretion disk model, suggesting a significant contribution from the secondary or from a synchrotron-emitting region. A follow-up observation performed when XTE J1814-338 was in quiescence reveals no counterpart to a limiting magnitude of R = 23.3. This suggests that the secondary is an M3 V or later-type star, and therefore very unlikely to be responsible for the soft excess, making synchroton emission a more reasonable candidate.Comment: Accepted for publication in ApJ. 6 pages; 3 figure


  • Open Access

    The X-ray Position and Optical Counterpart of the Accretion-Powered Millisecond Pulsar XTE J1814-338

    by Miriam I. Krauss, Zhongxiang Wang, Allyn Dullighan, Adrienne M. Juett, David L. Kaplan, Deepto Chakrabarty, Marten H. van Kerkwijk, Danny Steeghs, Peter G. Jonker, Craig B. Markwardt

    We report the precise optical and X-ray localization of the 3.2 ms accretion-powered X-ray pulsar XTE J1814-338 with data from the Chandra X-Ray Observatory as well as optical observations conducted during the 2003 June discovery outburst. Optical imaging of the field during the outburst of this soft X-ray transient reveals an R = 18 star at the X-ray position. This star is absent (R > 20) from an archival 1989 image of the field and brightened during the 2003 outburst, and we therefore identify it as the optical counterpart of XTE J1814-338. The best source position derived from optical astrometry is R.A. = 18h13m39.s04, Dec.= -33d46m22.3s (J2000). The featureless X-ray spectrum of the pulsar in outburst is best fit by an absorbed power-law (with photon index = 1.41 +- 0.06) plus blackbody (with kT = 0.95 +- 0.13 keV) model, where the blackbody component contributes approximately 10% of the source flux. The optical broad-band spectrum shows evidence for an excess of infrared emission with respect to an X-ray heated accretion disk model, suggesting a significant contribution from the secondary or from a synchrotron-emitting region. A follow-up observation performed when XTE J1814-338 was in quiescence reveals no counterpart to a limiting magnitude of R = 23.3. This suggests that the secondary is an M3 V or later-type star, and therefore very unlikely to be responsible for the soft excess, making synchroton emission a more reasonable candidate.

  • Open Access

    X‐Ray Spectroscopy of the Low‐Mass X‐Ray Binaries 2S 0918−549 and 4U 1543−624: Evidence for Neon‐rich Degenerate Donors

    by Adrienne M. Juett, Deepto Chakrabarty

    We present high-resolution spectroscopy of the neutron-star/low-mass X-ray binaries 2S 0918-549 and 4U 1543-624 with the High Energy Transmission Grating Spectrometer onboard the Chandra X-ray Observatory and the Reflection Grating Spectrometer onboard XMM-Newton. Previous low-resolution spectra of both sources showed a broad line-like feature at 0.7 keV that was originally attributed to unresolved line emission. We recently showed that this feature could also be due to excess neutral Ne absorption, and this is confirmed by the new high-resolution Chandra spectra. The Chandra spectra are each well fit by an absorbed power-law + blackbody model with a modified Ne/O number ratio of 0.52+/-0.12 for 2S 0918-549 and 1.5+/-0.3 for 4U 1543-624, compared to the interstellar-medium value of 0.18. The XMM spectrum of 2S 0918-549 is best fit by an absorbed power-law model with a Ne/O number ratio of 0.46+/-0.03, consistent with the Chandra result. On the other hand, the XMM spectrum of 4U 1543-624 is softer and less luminous than the Chandra spectrum and has a best-fit Ne/O number ratio of 0.54+/-0.03. The difference between the measured abundances and the expected interstellar ratio, as well as the variation of the column densities of O and Ne in 4U 1543-624, supports the suggestion that there is absorption local to these binaries. We propose that the variations in the O and Ne column densities of 4U 1543-624 are caused by changes in the ionization structure of the local absorbing material. It is important to understand the effect of ionization on the measured absorption columns before the abundance of the local material can be determined. This work supports our earlier suggestion that 2S 0918-549 and 4U 1543-624 are ultracompact binaries with Ne-rich companions.Comment: 11 pages, 5 figures, major revisions including addition of XMM spectral analysis, accepted for publication in the Astrophysical Journal, vol. 59


  • Open Access

    X-Ray Spectroscopy of the Low-Mass X-ray Binaries 2S 0918-549 and 4U1543-624: Evidence for Neon-Rich Degenerate Donors

    by Adrienne Juett, Deepto Chakrabarty

    We present high-resolution spectroscopy of the neutron-star/low-mass X-ray binaries 2S 0918-549 and 4U 1543-624 with the High Energy Transmission Grating Spectrometer onboard the Chandra X-ray Observatory and the Reflection Grating Spectrometer onboard XMM-Newton. Previous low-resolution spectra of both sources showed a broad line-like feature at 0.7 keV that was originally attributed to unresolved line emission. We recently showed that this feature could also be due to excess neutral Ne absorption, and this is confirmed by the new high-resolution Chandra spectra. The Chandra spectra are each well fit by an absorbed power-law + blackbody model with a modified Ne/O number ratio of 0.52+/-0.12 for 2S 0918-549 and 1.5+/-0.3 for 4U 1543-624, compared to the interstellar-medium value of 0.18. The XMM spectrum of 2S 0918-549 is best fit by an absorbed power-law model with a Ne/O number ratio of 0.46+/-0.03, consistent with the Chandra result. On the other hand, the XMM spectrum of 4U 1543-624 is softer and less luminous than the Chandra spectrum and has a best-fit Ne/O number ratio of 0.54+/-0.03. The difference between the measured abundances and the expected interstellar ratio, as well as the variation of the column densities of O and Ne in 4U 1543-624, supports the suggestion that there is absorption local to these binaries. We propose that the variations in the O and Ne column densities of 4U 1543-624 are caused by changes in the ionization structure of the local absorbing material. It is important to understand the effect of ionization on the measured absorption columns before the abundance of the local material can be determined. This work supports our earlier suggestion that 2S 0918-549 and 4U 1543-624 are ultracompact binaries with Ne-rich companions.

  • Open Access

    X-ray Spectroscopy of the Accreting Millisecond Pulsar XTE J0929-314 in Outburst

    by Adrienne M. Juett, Duncan K. Galloway, Deepto Chakrabarty

    We present the high-resolution spectrum of the accretion-powered millisecond pulsar XTE J0929-314 during its 2002 outburst, measured using the Low Energy Transmission Grating Spectrometer onboard the Chandra X-ray Observatory. The 1.5-25.3 A (0.5-8.3 keV) Chandra spectrum is well fit by a power-law + blackbody model with photon index Gamma=1.55+/-0.03, blackbody temperature kT_bb=0.65+/-0.03 keV, and blackbody normalization R_bb,km/d_10kpc=7.6+/-0.8. No emission or absorption features are found in the high-resolution spectrum, with a 3 sigma equivalent width upper limit of <0.007 A at 1.5 A and <0.12 A at 24 A. The neutral absorption edge depths are consistent with the estimated interstellar absorption along the line of sight to the source. We found no orbital modulation of the 2-10 keV X-ray flux, to a 3 sigma upper limit of 1.1%, which implies an upper limit on the binary inclination angle of i<85deg for a Roche-lobe-filling companion. We also present the broadband spectrum measured over the course of the outburst by the Rossi X-ray Timing Explorer. The XTE spectrum of XTE J0929-314 is also well fit with a power-law + blackbody model, with average values of Gamma=1.76+/-0.03, kT_bb=0.66+/-0.06 keV, and R_bb,km/d_10kpc=5.9+/-1.3 in the 2-50 keV energy range. The blackbody flux remained constant over the course of the outburst, while the power-law flux was strongly correlated to the (decreasing) flux of the source. We find that the difference in power-law photon indices measured from Chandra and XTE spectra can be explained by a change in the power-law photon index at low energies.

  • Open Access

    [ITAL]Chandra[/ITAL] High-Resolution Spectrum of the Anomalous X-Ray Pulsar 4U 0142+61

    by Adrienne M. Juett, Herman L. Marshall, Deepto Chakrabarty, Norbert S. Schulz

    We report on a 25 ks observation of the 8.7 s anomalous X-ray pulsar 4U~0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody with photon index Gamma=3.3+/-0.4 and kT=0.418+/-0.013 keV. No evidence was found for emission or absorption lines, with an upper limit of ~50 eV on the equivalent width of broad features in the 2.5-13 A (0.95-5.0 keV) range and an upper limit of ~10 eV on the equivalent width of narrow features in the 4.1-17.7 A (0.7-3.0 keV) range. If the source is a magnetar, then the absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. We find no strong features that are indicative of cyclotron absorption for magnetic field strengths of (1.9-9.8)x10^{14} G. This is still consistent with the dipole field strength of B=1.3x10^{14} G (at the polar cap) estimated from the pulsar's spindown.


  • Open Access

    The X-Ray Position and Infrared Counterpart of the Eclipsing X-Ray Pulsar OAO 1657-415

    by Deepto Chakrabarty, Zhongxiang Wang, Adrienne M. Juett, Julia C. Lee, Paul Roche

    We have measured the precise position of the 38-s eclipsing X-ray pulsar OAO 1657-415 with the Chandra X-Ray Observatory: RA = 17h00m48.90s, Dec = -41d39m21.6s, equninox J2000, error radius = 0.5 arcsec. Based on the previously measured pulsar mass function and X-ray eclipse duration, this 10.4-d high-mass X-ray binary is believed to contain a B supergiant companion. Deep optical imaging of the field did not detect any stars at the Chandra source position, setting a limit of V>23. However, near-IR imaging revealed a relatively bright star (J=14.1, H=11.9, K_s=10.7) coincident with the Chandra position, and we identify this star as the IR counterpart of OAO 1657-415. The IR colors and magnitudes and the optical non-detections for this star are all consistent with a highly reddened B supergiant (A_V= 20.4 +/- 1.3) at a distance of 6.4 +/- 1.5 kpc. This implies an X-ray luminosity of 3e36 erg/s (2-10 keV). IR spectroscopy can verify the spectral type of the companion and measure its radial velocity curve, yielding a neutron star mass measurement.

  • Open Access

    Chandra High-Resolution Spectrum of the Anomalous X-ray Pulsar 4U 0142+61

    by Adrienne M. Juett, Herman L. Marshall, Deepto Chakrabarty, Norbert S. Schulz

    We report on a 25 ks observation of the 8.7 s anomalous X-ray pulsar 4U~0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody with photon index Gamma=3.3+/-0.4 and kT=0.418+/-0.013 keV. No evidence was found for emission or absorption lines, with an upper limit of ~50 eV on the equivalent width of broad features in the 2.5-13 A (0.95-5.0 keV) range and an upper limit of ~10 eV on the equivalent width of narrow features in the 4.1-17.7 A (0.7-3.0 keV) range. If the source is a magnetar, then the absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. We find no strong features that are indicative of cyclotron absorption for magnetic field strengths of (1.9-9.8)x10^{14} G. This is still consistent with the dipole field strength of B=1.3x10^{14} G (at the polar cap) estimated from the pulsar's spindown.

  • Open Access

    Ultracompact X-Ray Binaries with Neon-rich Degenerate Donors

    by Adrienne M. Juett, Dimitrios Psaltis, Deepto Chakrabarty

    There are three low-mass X-ray binaries (4U 0614+091, 2S 0918-549, and 4U 1543-624) for which broad-line emission near 0.7 keV was previously reported. A recent high-resolution observation of 4U 0614+091 with the Chandra Low-Energy Transmission Grating Spectrometer (LETGS) found evidence of an unusually high Ne/O abundance ratio along the line of sight but failed to detect the previously reported 0.7 keV feature. We have made a search of archival ASCA spectra and identified a fourth source with the 0.7 keV feature, the 20 minute ultracompact binary 4U 1850-087. In all four of these sources, the 0.7 keV residual is eliminated from the ASCA spectra by allowing excess photoelectric absorption due to a nonsolar relative abundance of neon, just as in the LETGS spectrum of 4U 0614+091. The optical properties of these systems suggest that all four are ultracompact (Porb < 80 minutes) binaries. We propose that there is excess neon local to each of these sources, as also found in the ultracompact binary pulsar 4U 1626-67. We suggest that the mass donor in these systems is a low-mass, neon-rich degenerate dwarf and that the binaries are all ultracompact.


  • Open Access

    Anomalous X‐Ray Pulsars and Soft Gamma‐Ray Repeaters: Spectral Fits and the Magnetar Model

    by Rosalba Perna, Jeremy S. Heyl, Lars E. Hernquist, Adrienne M. Juett, Deepto Chakrabarty

    The energy source powering the X-ray emission from anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs) is still uncertain. In one scenario, the presence of an ultramagnetized neutron star, or ``magnetar'', with B on the order of 10^{14} - 10^{15} G is invoked. To investigate this hypothesis, we have analyzed archival ASCA data for several known AXPs and SGRs, and fitted them with a model in which all or part of the X-ray flux originates as thermal emission from a magnetar. Our magnetar spectral model includes the effects of the anisotropy of the heat flow through an ultramagnetized neutron star envelope, reprocessing by a light element atmosphere, and general relativistic corrections to the observed spectrum. We obtain good fits to the data with radii for the emitting areas which are generally consistent with those expected for neutron stars, in contrast to blackbody (BB) fits, which imply much smaller radii. Furthermore, the inclusion of atmospheric effects results in inferred temperatures which are lower than those implied by BB fits, but however still too high to be accounted by thermal cooling alone. An extra source of heating (possibly due to magnetic field decay) is needed. Despite the harder tail in the spectrum produced by reprocessing of the outgoing flux through the atmosphere, spectral fits still require a considerable fraction of the flux to be in a power-law component.Comment: 14 pages, 2 tables, 1 figure, ApJ in press; note added to Table