Christopher Frewin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher Frewin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
A. Kumar
Mechanical Engineering Department, University of South Florida, Tampa, FL 33620, USA
1 shared publicationA. Oliveros
Electrical Engineering Department, University of South Florida, Tampa, FL 33620, USA
1 shared publication- Alex A. Volinsky
Department of Mechanical and Aerospace Engineering University of South Florida Tampa Florida USA
1 shared publication C. Locke
Univ S Florida, Dept Elect Engn, Tampa, FL 33620 USA
1 shared publicationChris Locke
University of South Florida, Department of Electrical Engineering, 4202 E. Fowler Ave. ENB118, Tampa, FL, 33620, United States
1 shared publicationE. Weeber
Florida Center of Excellence for Biomolecular Identification and Targeted Therapeutics (FCoE‐BITT), University of South Florida, Tampa, FL 33620, USA
1 shared publication
Latest Publications
- 1 August 2009
- Published by Elsevier in Journal of Crystal Growth
- Vol. 311 (17) , 4179-4182
Growth of cubic silicon carbide on oxide using polysilicon as a seed layer for micro-electro-mechanical machine applications
- 1 August 2009
- Published by Elsevier in Journal of Crystal Growth
- Vol. 311 (17) , 4179-4182
Growth of cubic silicon carbide on oxide using polysilicon as a seed layer for micro-electro-mechanical machine applications
- 7 July 2009
- Published by Wiley in Journal of Molecular Recognition
- Vol. 22 (5) , 380-388
Atomic force microscopy analysis of central nervous system cell morphology on silicon carbide and diamond substrates
Brain machine interface (BMI) devices offer a platform that can be used to assist people with extreme disabilities, such as amyotrophic lateral sclerosis (ALS) and Parkinson's disease. Silicon (Si) has been the material of choice used for the manufacture of BMI devices due to its mechanical strength, its electrical properties and multiple fabrication techniques; however, chronically implanted BMI devices have usually failed within months of implantation due to biocompatibility issues and the fact that Si does not withstand the harsh environment of the body. Single crystal cubic silicon carbide (3C‐SiC) and nanocrystalline diamond (NCD) are semiconductor materials that have previously shown good biocompatibility with skin and bone cells. Like Si, these materials have excellent physical characteristics, good electrical properties, but unlike Si, they are chemically inert. We have performed a study to evaluate the general biocompatibility levels of all of these materials through the use of in vitro techniques. H4 human neuroglioma and PC12 rat pheochromocytoma cell lines were used for the study, and polystyrene (PSt) and amorphous glass were used as controls or for morphological comparison. MTT [3‐(4,5‐Dimethylthiazol‐2‐Yl)‐2,5‐Diphenyltetrazolium Bromide] assays were performed to determine general cell viability with each substrate and atomic force microscopy (AFM) was used to quantify the general cell morphology on the substrate surface along with the substrate permissiveness to lamellipodia extension. 3C‐SiC was the only substrate tested to have good viability and superior lamellipodia permissiveness with both cell lines, while NCD showed a good level of viability with the neural H4 line but a poor viability with the PC12 line and lower permissiveness than 3C‐SiC. Explanations pertaining to the performance of each substrate with both cell lines are presented and discussed along with future work that must be performed to further evaluate specific cell reactions on these substrates. Copyright © 2009 John Wiley & Sons, Ltd.
- 7 July 2009
- Published by Wiley in Journal of Molecular Recognition
- Vol. 22 (5) , 380-388
Atomic force microscopy analysis of central nervous system cell morphology on silicon carbide and diamond substrates
Brain machine interface (BMI) devices offer a platform that can be used to assist people with extreme disabilities, such as amyotrophic lateral sclerosis (ALS) and Parkinson's disease. Silicon (Si) has been the material of choice used for the manufacture of BMI devices due to its mechanical strength, its electrical properties and multiple fabrication techniques; however, chronically implanted BMI devices have usually failed within months of implantation due to biocompatibility issues and the fact that Si does not withstand the harsh environment of the body. Single crystal cubic silicon carbide (3C‐SiC) and nanocrystalline diamond (NCD) are semiconductor materials that have previously shown good biocompatibility with skin and bone cells. Like Si, these materials have excellent physical characteristics, good electrical properties, but unlike Si, they are chemically inert. We have performed a study to evaluate the general biocompatibility levels of all of these materials through the use of in vitro techniques. H4 human neuroglioma and PC12 rat pheochromocytoma cell lines were used for the study, and polystyrene (PSt) and amorphous glass were used as controls or for morphological comparison. MTT [3‐(4,5‐Dimethylthiazol‐2‐Yl)‐2,5‐Diphenyltetrazolium Bromide] assays were performed to determine general cell viability with each substrate and atomic force microscopy (AFM) was used to quantify the general cell morphology on the substrate surface along with the substrate permissiveness to lamellipodia extension. 3C‐SiC was the only substrate tested to have good viability and superior lamellipodia permissiveness with both cell lines, while NCD showed a good level of viability with the neural H4 line but a poor viability with the PC12 line and lower permissiveness than 3C‐SiC. Explanations pertaining to the performance of each substrate with both cell lines are presented and discussed along with future work that must be performed to further evaluate specific cell reactions on these substrates. Copyright © 2009 John Wiley & Sons, Ltd.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1069
Residual Stress in CVD-grown 3C-SiC Films on Si Substrates
Having superior mechanical properties, 3C-SiC is one of the target materials for power MEMS applications. Growing 3C-SiC films on Si is challenging, as there is a large mismatch in lattice parameter and thermal expansion between the SiC film and the Si substrate that needs to be accommodated, and results in high residual stress. Residual stress control is critical in MEMS devices as upon feature release it results in substantial deformation.3C-SiC single crystalline films were deposited on 50 mm (100) and (111) Si substrates in a hot-wall CVD reactor. The film tensile residual stress was so high that it fractured on the (111) Si wafer. The resulting film thickness on the (100) Si wafer was non-uniform, having a linear profile along the growth direction. This presented a challenge of using the substrate curvature method for calculating residual stress. Finite Element Method correction was applied to the Stoney's formula for calculating the residual stress along the wafer radius. Suggestions for reducing the amount of residual stress are made.
- 1 January 2008
- Published by Springer Nature in MRS Proceedings
- Vol. 1069
Residual Stress in CVD-grown 3C-SiC Films on Si Substrates
Having superior mechanical properties, 3C-SiC is one of the target materials for power MEMS applications. Growing 3C-SiC films on Si is challenging, as there is a large mismatch in lattice parameter and thermal expansion between the SiC film and the Si substrate that needs to be accommodated, and results in high residual stress. Residual stress control is critical in MEMS devices as upon feature release it results in substantial deformation.3C-SiC single crystalline films were deposited on 50 mm (100) and (111) Si substrates in a hot-wall CVD reactor. The film tensile residual stress was so high that it fractured on the (111) Si wafer. The resulting film thickness on the (100) Si wafer was non-uniform, having a linear profile along the growth direction. This presented a challenge of using the substrate curvature method for calculating residual stress. Finite Element Method correction was applied to the Stoney's formula for calculating the residual stress along the wafer radius. Suggestions for reducing the amount of residual stress are made.