CécIle B. Grandin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
CécIle B. Grandin has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Thierry Duprez
Département de Radiologie et d’ Imagerie médicale, Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Brussels, Belgium
5 shared publications Anne M. Smith
Department of Radiology, St Luc University Hospital, Université Catholique de Louvain, 10, Avenue Hippocrate, B-1200 Brussels, Belgium
3 shared publicationsGuy Cosnard
Department of Radiology, St Luc University Hospital, Université Catholique de Louvain, 10, Avenue Hippocrate, B-1200 Brussels, Belgium
3 shared publications- Guy Cosnard
Cliniques Universitaires Saint-Luc UCL, avenue Hippocrate 10, 1200 Bruxelles, Belgique
3 shared publications - Catherine Oppenheim
Université Paris Cité, Institute of Psychiatry and Neuroscience of Paris (IPNP), INSERM U1266, IMA-Brain, 75014 Paris, France
2 shared publications - Philippe Mathurin
Université Lille, CHU de Lille, Service des maladies de l'appareil digestif, Hôpital Huriez, INFINITE-U1286, Lille, France
2 shared publications
Latest Publications
- 30 June 2005
- Published by Elsevier in NeuroImage
- Vol. 26 (2) , 525-35
Absolute CBF and CBV measurements by MRI bolus tracking before and after acetazolamide challenge: Repeatabilily and comparison with PET in humans
- 30 June 2005
- Published by Elsevier in NeuroImage
- Vol. 26 (2) , 525-35
Absolute CBF and CBV measurements by MRI bolus tracking before and after acetazolamide challenge: Repeatabilily and comparison with PET in humans
- 1 January 2004
- Published by Springer Nature in Neuroradiology
- Vol. 46 (1) , 2
Assessment of brain perfusion with MRI: methodology and application to acute stroke
- 1 January 2004
- Published by Springer Nature in Neuroradiology
- Vol. 46 (1) , 2
Assessment of brain perfusion with MRI: methodology and application to acute stroke
- 1 November 2003
- Published by Springer Nature in Neuroradiology
- Vol. 45 (11) , 755-766
Assessment of brain perfusion with MRI: methodology and application to acute stroke
We review the methodology of brain perfusion measurements with MRI and their application to acute stroke, with particular emphasis on the work awarded by the 6th Lucien Appel Prize for Neuroradiology. The application of the indicator dilution theory to the dynamic susceptibility-weighted bolus-tracking method is explained, as is the approach to obtaining quantitative measurements of cerebral blood flow (CBF) and volume (CBV). Our contribution to methodological developments, such as CBV measurement with the frequency-shifted burst sequence, development of the PRESTO sequence, comparison of different deconvolution methods and of spin- and gradient-echo sequences, and the validation of MRI measurements against positron emission tomography is summarised. The pathophysiology of brain ischaemia and the role of neuroimaging in the setting of acute stroke are reviewed, with an introduction to the concepts of ischaemic penumbra and diffusion/perfusion mismatch. Our work on the determination of absolute CBF and CBV thresholds for predicting the area of infarct growth, identification of the best perfusion parameters (relative or absolute) for predicting the area of infarct growth and the role of MR angiography is also summarised. We conclude that MRI is a very powerful way to assess brain perfusion and that its use might help in selecting patients who will benefit most from treatment such as thrombolysis.
- 1 November 2003
- Published by Springer Nature in Neuroradiology
- Vol. 45 (11) , 755-766
Assessment of brain perfusion with MRI: methodology and application to acute stroke
We review the methodology of brain perfusion measurements with MRI and their application to acute stroke, with particular emphasis on the work awarded by the 6th Lucien Appel Prize for Neuroradiology. The application of the indicator dilution theory to the dynamic susceptibility-weighted bolus-tracking method is explained, as is the approach to obtaining quantitative measurements of cerebral blood flow (CBF) and volume (CBV). Our contribution to methodological developments, such as CBV measurement with the frequency-shifted burst sequence, development of the PRESTO sequence, comparison of different deconvolution methods and of spin- and gradient-echo sequences, and the validation of MRI measurements against positron emission tomography is summarised. The pathophysiology of brain ischaemia and the role of neuroimaging in the setting of acute stroke are reviewed, with an introduction to the concepts of ischaemic penumbra and diffusion/perfusion mismatch. Our work on the determination of absolute CBF and CBV thresholds for predicting the area of infarct growth, identification of the best perfusion parameters (relative or absolute) for predicting the area of infarct growth and the role of MR angiography is also summarised. We conclude that MRI is a very powerful way to assess brain perfusion and that its use might help in selecting patients who will benefit most from treatment such as thrombolysis.
- 1 May 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 223 (2) , 361-370
Which MR-derived Perfusion Parameters are the Best Predictors of Infarct Growth in Hyperacute Stroke? Comparative Study between Relative and Quantitative Measurements
To compare predictors of infarct growth in hyperacute stroke from a retrospective review of various relative and quantitative parameters calculated at perfusion-weighted magnetic resonance (MR) imaging performed within 6 hours after ictus. Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted images were obtained in 66 patients. The initial infarct was delineated on diffusion-weighted images; the hemodynamic disturbance, on apparent mean transit time (MTT) maps; and the final infarct, on follow-up fluid-attenuated inversion recovery images. Relative (without and with deconvolution) and quantitative values of the bolus arrival time, time to peak (TTP), apparent MTT or MTT, cerebral blood volume (CBV), peak height, and cerebral blood flow (CBF) index or CBF were calculated for initial infarct, infarct growth (final minus initial infarct contour), viable hemodynamic disturbance (apparent MTT minus final infarct contour), and contralateral mirror regions. Univariate and multivariate analyses (receiver operating characteristic curves and discriminant analysis) were performed to compare the diagnostic performance of these parameters for predicting infarct growth. At univariate analysis, relative peak height and quantitative CBF were the best predictors of infarct growth; at multivariate analysis, a function of peak height and TTP for relative measurements and CBF alone for quantitative measurements. Quantitative and relative measurements (without or with deconvolution) worked equally well. A combined relative peak height or TTP threshold (5.2 seconds, respectively) had a sensitivity of 71% and a specificity of 98%. A quantitative CBF threshold (<35 mL/min/100 g) had a sensitivity of 69% and a specificity of 85%. A combination of relative peak height and TTP measurements allowed the best prediction of infarct growth, which obviates more complex quantitative calculation.
- 1 May 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 223 (2) , 361-370
Which MR-derived Perfusion Parameters are the Best Predictors of Infarct Growth in Hyperacute Stroke? Comparative Study between Relative and Quantitative Measurements
To compare predictors of infarct growth in hyperacute stroke from a retrospective review of various relative and quantitative parameters calculated at perfusion-weighted magnetic resonance (MR) imaging performed within 6 hours after ictus. Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted images were obtained in 66 patients. The initial infarct was delineated on diffusion-weighted images; the hemodynamic disturbance, on apparent mean transit time (MTT) maps; and the final infarct, on follow-up fluid-attenuated inversion recovery images. Relative (without and with deconvolution) and quantitative values of the bolus arrival time, time to peak (TTP), apparent MTT or MTT, cerebral blood volume (CBV), peak height, and cerebral blood flow (CBF) index or CBF were calculated for initial infarct, infarct growth (final minus initial infarct contour), viable hemodynamic disturbance (apparent MTT minus final infarct contour), and contralateral mirror regions. Univariate and multivariate analyses (receiver operating characteristic curves and discriminant analysis) were performed to compare the diagnostic performance of these parameters for predicting infarct growth. At univariate analysis, relative peak height and quantitative CBF were the best predictors of infarct growth; at multivariate analysis, a function of peak height and TTP for relative measurements and CBF alone for quantitative measurements. Quantitative and relative measurements (without or with deconvolution) worked equally well. A combined relative peak height or TTP threshold (5.2 seconds, respectively) had a sensitivity of 71% and a specificity of 98%. A quantitative CBF threshold (<35 mL/min/100 g) had a sensitivity of 69% and a specificity of 85%. A combination of relative peak height and TTP measurements allowed the best prediction of infarct growth, which obviates more complex quantitative calculation.
- 1 May 2001
- Published by Wolters Kluwer Health in Stroke
- Vol. 32 (5) , 1147-1153
Usefulness of Magnetic Resonance–Derived Quantitative Measurements of Cerebral Blood Flow and Volume in Prediction of Infarct Growth in Hyperacute Stroke
Background and Purpose —The identification of the tissue at risk for infarction remains challenging in stroke patients. In this study, we evaluated the value of quantitative cerebral blood flow (CBF) and cerebral blood volume (CBV) measurements in the prediction of infarct growth in hyperacute stroke. Methods —Fluid-attenuated inversion recovery (FLAIR), diffusion-weighted (DW), and gradient-echo echo-planar perfusion-weighted (PW) sequences were obtained in 66 patients within 6 hours of stroke onset; ischemia was confirmed on follow-up FLAIR images. We delineated the following: (1) the initial infarct on DW images, (2) the area of hemodynamic disturbance on mean transit time (MTT) maps, and (3) the final infarct on follow-up FLAIR images. MTT, CBF, and CBV were calculated in the following areas: area of initial infarct (INF), area of infarct growth (IGR, final minus initial infarct), the hemodynamically disturbed area that remained viable (OLI, hemodynamic disturbance minus final infarct), and all contralateral mirror regions. Results —Compared with mirror regions, the MTT in abnormal areas was always prolonged. The respective mean±SD CBF and CBV values were as follows: for INF, 28±16 mL/min per 100 g and 6.9±2.7%; for IGR, 36±20 mL/min per 100 g and 8.9±3.1%; for OLI, 50±17 mL/min per 100 g and 11.2±3%; and for mirror regions, 64±23 mL/min per 100 g and 8.7±2.5%. The CBV and CBF values were significantly different between all abnormal areas (except for the CBF between INF and IGR). In the area of DW/PW mismatch, a combined CBF or CBV threshold of 35 or 8.2, respectively, predicted evolution to infarction with a sensitivity of 81% and a specificity of 76%. Conclusions —Quantitative measurements of CBF and CBV in hyperacute stroke may help to predict infarct growth and to select the subjects who will benefit from thrombolysis.
- 1 May 2001
- Published by Wolters Kluwer Health in Stroke
- Vol. 32 (5) , 1147-1153
Usefulness of Magnetic Resonance–Derived Quantitative Measurements of Cerebral Blood Flow and Volume in Prediction of Infarct Growth in Hyperacute Stroke
Background and Purpose —The identification of the tissue at risk for infarction remains challenging in stroke patients. In this study, we evaluated the value of quantitative cerebral blood flow (CBF) and cerebral blood volume (CBV) measurements in the prediction of infarct growth in hyperacute stroke. Methods —Fluid-attenuated inversion recovery (FLAIR), diffusion-weighted (DW), and gradient-echo echo-planar perfusion-weighted (PW) sequences were obtained in 66 patients within 6 hours of stroke onset; ischemia was confirmed on follow-up FLAIR images. We delineated the following: (1) the initial infarct on DW images, (2) the area of hemodynamic disturbance on mean transit time (MTT) maps, and (3) the final infarct on follow-up FLAIR images. MTT, CBF, and CBV were calculated in the following areas: area of initial infarct (INF), area of infarct growth (IGR, final minus initial infarct), the hemodynamically disturbed area that remained viable (OLI, hemodynamic disturbance minus final infarct), and all contralateral mirror regions. Results —Compared with mirror regions, the MTT in abnormal areas was always prolonged. The respective mean±SD CBF and CBV values were as follows: for INF, 28±16 mL/min per 100 g and 6.9±2.7%; for IGR, 36±20 mL/min per 100 g and 8.9±3.1%; for OLI, 50±17 mL/min per 100 g and 11.2±3%; and for mirror regions, 64±23 mL/min per 100 g and 8.7±2.5%. The CBV and CBF values were significantly different between all abnormal areas (except for the CBF between INF and IGR). In the area of DW/PW mismatch, a combined CBF or CBV threshold of 35 or 8.2, respectively, predicted evolution to infarction with a sensitivity of 81% and a specificity of 76%. Conclusions —Quantitative measurements of CBF and CBV in hyperacute stroke may help to predict infarct growth and to select the subjects who will benefit from thrombolysis.
- 1 October 2000
- Vol. 21 (9) , 1611-1617
Vasospasm after Subarachnoid Hemorrhage: Diagnosis with MR Angiography
BACKGROUND AND PURPOSE: The possibility of treating intracranial vasospasm has increased the significance of its diagnosis and follow-up; however, so far, no ideal method is available. The goal of this study was to assess the accuracy of MR angiography versus intraarterial angiography (IA-DSA) in detecting vasospasm.
- 1 October 2000
- Vol. 21 (9) , 1611-1617
Vasospasm after Subarachnoid Hemorrhage: Diagnosis with MR Angiography
BACKGROUND AND PURPOSE: The possibility of treating intracranial vasospasm has increased the significance of its diagnosis and follow-up; however, so far, no ideal method is available. The goal of this study was to assess the accuracy of MR angiography versus intraarterial angiography (IA-DSA) in detecting vasospasm.
- 1 June 2000
- Vol. 27 (2) , 119-27
[Degree of hemodynamic disturbance at the hyperacute phase of stroke: predictive value of 3D-TOF angiography and the T2 fast-FLAIR sequence].
To define during the hyperacute phase of stroke the value of 3D-TOF MR angiography (MRA) and T2 fast-FLAIR sequence for predicting the volume of tissue presenting a hemodynamic disturbance. and method: Thirty-five cases of hyperacute stroke located in following territories: middle cerebral artery (MCA) (n=29), anterior choroidal artery (AChoA) (n=5) and watershed (n=1) were retrospectively reviewed. The vascular abnormalities defined on MRA (vessel stenosis or occlusion) or FLAIR sequence (vessel hyperintensity) were classified into 3 groups: normal (I), distal abnormalities (II), abnormalities of the entire arterial territory (III). These results were compared with the volume of tissue showing a prolonged mean transit time (MTT) determined on relative MTT maps calculated from bolus tracking MR perfusion images. The abnormal volume measured on the MTT map was significantly correlated to the results of the MRA and FLAIR sequence. In the 12 cases of group III defined on the MRA (abnormality from M1), the volume of hemodynamic disturbance was always higher than 100 ml. For the MCA territory, it was not possible to predict the presence of a hemodynamic disturbance in any of the 3 groups defined on the FLAIR sequence and in the groups I and II defined on the MRA. For the AChoA territory, a hemodynamic disturbance was never observed in groups I and II defined either on MRA or FLAIR sequence. When there was no flow within the M1 segment on the MRA, there was always a hemodynamic disturbance larger than 100 ml on the MTT map. In the case of AChoA ischemic lesion, when no vascular abnormality was observed on the MRA or FLAIR images, the MTT map was always normal.
- 1 June 2000
- Vol. 27 (2) , 119-27
[Degree of hemodynamic disturbance at the hyperacute phase of stroke: predictive value of 3D-TOF angiography and the T2 fast-FLAIR sequence].
To define during the hyperacute phase of stroke the value of 3D-TOF MR angiography (MRA) and T2 fast-FLAIR sequence for predicting the volume of tissue presenting a hemodynamic disturbance. and method: Thirty-five cases of hyperacute stroke located in following territories: middle cerebral artery (MCA) (n=29), anterior choroidal artery (AChoA) (n=5) and watershed (n=1) were retrospectively reviewed. The vascular abnormalities defined on MRA (vessel stenosis or occlusion) or FLAIR sequence (vessel hyperintensity) were classified into 3 groups: normal (I), distal abnormalities (II), abnormalities of the entire arterial territory (III). These results were compared with the volume of tissue showing a prolonged mean transit time (MTT) determined on relative MTT maps calculated from bolus tracking MR perfusion images. The abnormal volume measured on the MTT map was significantly correlated to the results of the MRA and FLAIR sequence. In the 12 cases of group III defined on the MRA (abnormality from M1), the volume of hemodynamic disturbance was always higher than 100 ml. For the MCA territory, it was not possible to predict the presence of a hemodynamic disturbance in any of the 3 groups defined on the FLAIR sequence and in the groups I and II defined on the MRA. For the AChoA territory, a hemodynamic disturbance was never observed in groups I and II defined either on MRA or FLAIR sequence. When there was no flow within the M1 segment on the MRA, there was always a hemodynamic disturbance larger than 100 ml on the MTT map. In the case of AChoA ischemic lesion, when no vascular abnormality was observed on the MRA or FLAIR images, the MTT map was always normal.
- 1 February 1998
- Vol. 19 (2) , 245-252
Diagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T.
Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thickness of 30 mm. Conventional spin-echo MR images and MR angiograms were reviewed together, and the results were compared with those obtained at intraarterial cerebral angiography to determine the sensitivity and specificity of MR angiography. Eighty-nine aneurysms (size range, 2 to 27 mm; 25 aneurysms < 5 mm) were identified at intraarterial cerebral angiography. Six aneurysms were missed by MR angiography and two were doubtful (sensitivity, 91% to 93%; specificity, 100%). Missed aneurysms were located outside the MR angiographic acquisition volume (n = 3) or on the carotid siphon (n = 3; size = 2, 3, and 5 mm). Even if MR angiography presents some restrictions in acquisition volume and spatial resolution, the detection rate of intracranial aneurysms is excellent at 0.5 T in both asymptomatic patients and in those with subarachnoid hemorrhage. A midfield system is not a restriction to the detection of intracranial aneurysms by MR examination.
- 1 February 1998
- Vol. 19 (2) , 245-252
Diagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T.
Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thickness of 30 mm. Conventional spin-echo MR images and MR angiograms were reviewed together, and the results were compared with those obtained at intraarterial cerebral angiography to determine the sensitivity and specificity of MR angiography. Eighty-nine aneurysms (size range, 2 to 27 mm; 25 aneurysms < 5 mm) were identified at intraarterial cerebral angiography. Six aneurysms were missed by MR angiography and two were doubtful (sensitivity, 91% to 93%; specificity, 100%). Missed aneurysms were located outside the MR angiographic acquisition volume (n = 3) or on the carotid siphon (n = 3; size = 2, 3, and 5 mm). Even if MR angiography presents some restrictions in acquisition volume and spatial resolution, the detection rate of intracranial aneurysms is excellent at 0.5 T in both asymptomatic patients and in those with subarachnoid hemorrhage. A midfield system is not a restriction to the detection of intracranial aneurysms by MR examination.
- 1 September 1996
- Vol. 17 (8) , 1589-1591
Whipple disease confined to the central nervous system in childhood.
In a case of pediatric Whipple disease confined to the central nervous system, white matter lesions initially appeared as areas of very low signal intensity on T1-weighted MR images and as areas of hyperintensity on proton density-weighted and T2-weighted images, and showed slight peripheral enhancement on delayed contrast-enhanced T1-weighted images. On MR studies obtained 3 and 6 months after antibiotic therapy, the lesions had decreased in size and no longer enhanced. They became progressively less hypointense on T1-weighted images and less hyperintense on T2-weighted images.
- 1 September 1996
- Vol. 17 (8) , 1589-1591
Whipple disease confined to the central nervous system in childhood.
In a case of pediatric Whipple disease confined to the central nervous system, white matter lesions initially appeared as areas of very low signal intensity on T1-weighted MR images and as areas of hyperintensity on proton density-weighted and T2-weighted images, and showed slight peripheral enhancement on delayed contrast-enhanced T1-weighted images. On MR studies obtained 3 and 6 months after antibiotic therapy, the lesions had decreased in size and no longer enhanced. They became progressively less hypointense on T1-weighted images and less hyperintense on T2-weighted images.