Alison J. E. Qualtrough
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alison J. E. Qualtrough has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- David Christopher Watts
Biomaterials Science, Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Photon Science Institute, University of Manchester, UK
2 shared publications A. Madarati
Unit of Endodontology
1 shared publication- David G Purton
Department of Oral Rehabilitation, University of Otago School of Dentistry, Dunedin, New Zealand
1 shared publication - Francesco Mannocci
Department of Endodontics, Centre of Oral Clinical & Translational Sciences, Faculty of Dentistry, Oral & Craniofacial Sciences, Guy’s Dental Hospital, King’s College London, London WC2R 2LS, UK
1 shared publication Hans G. Kurer
School of Dentistry, The University of Manchester, Manchester, United Kingdom
1 shared publicationHelen V Worthington
University Dental Hospital of Manchester
1 shared publication
Latest Publications
- 1 October 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (7) , 532-537
Is a “Flexible” Glass Fiber‐Bundle Dowel System as Retentive as a “Rigid” Quartz Fiber Dowel System?
This study had two aims: (1) to compare the retention of a flexible directly placed fiber-bundle dowel system with that of a rigid prefabricated fiber-reinforced composite (FRC) dowel system, and (2) to determine the effect of decreasing the volume of luting cement around the flexible fiber-bundle dowels on the axial retention of the restorations. Single-canal premolars (n = 36) were decoronated, cleaned, shaped, and prepared for both flexible and rigid dowels to a depth of 10 mm using a size 2 drill. The roots were then randomly allocated into three groups: Ia, Ib, and II (n = 12). Flexible fiber-bundle dowels were placed in groups Ia and Ib. These were available in three fiber-bundle diameters: small (0.9 mm), medium (1.2 mm), and large (1.5 mm). These bundles were luted in the root canals with Variolink II. The differences between Ia and Ib were in the ratio of the volume of fiber-bundles to the volume of luting cement and in the mode of application. Medium fiber-bundles were placed to the end of the preparation in groups Ia and Ib; however, in group Ia, a small diameter auxiliary bundle was placed, whereas in group Ib, a large-diameter auxiliary bundle was cut axially into strips of circa 0.2-mm thickness before being sequentially overlapped in placement. Roots in group II were restored with size 2 rigid prefabricated fiber dowels and luted with the light-cured cement provided by the manufacturer. After 24 hours of storage, axial tensile forces were applied to all luted dowels progressively to failure at 0.5 mm/min. Data were analyzed using a one-way analysis of variance (ANOVA) and the Bonferonni test. The mean axial resistance forces (standard deviation [SD]) for groups Ia, Ib, and II were not statistically different at 166 (49), 157 (36), and 151 (44) N, respectively (p > 0.05). There was no significant difference between the retention of the flexible fiber-bundle dowel system and that of the rigid prefabricated fiber dowel system. Decreasing the volume of luting cement around the flexible dowels did not have a significant effect on the axial retention of the restorations.
- 1 October 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (7) , 532-537
Is a “Flexible” Glass Fiber‐Bundle Dowel System as Retentive as a “Rigid” Quartz Fiber Dowel System?
This study had two aims: (1) to compare the retention of a flexible directly placed fiber-bundle dowel system with that of a rigid prefabricated fiber-reinforced composite (FRC) dowel system, and (2) to determine the effect of decreasing the volume of luting cement around the flexible fiber-bundle dowels on the axial retention of the restorations. Single-canal premolars (n = 36) were decoronated, cleaned, shaped, and prepared for both flexible and rigid dowels to a depth of 10 mm using a size 2 drill. The roots were then randomly allocated into three groups: Ia, Ib, and II (n = 12). Flexible fiber-bundle dowels were placed in groups Ia and Ib. These were available in three fiber-bundle diameters: small (0.9 mm), medium (1.2 mm), and large (1.5 mm). These bundles were luted in the root canals with Variolink II. The differences between Ia and Ib were in the ratio of the volume of fiber-bundles to the volume of luting cement and in the mode of application. Medium fiber-bundles were placed to the end of the preparation in groups Ia and Ib; however, in group Ia, a small diameter auxiliary bundle was placed, whereas in group Ib, a large-diameter auxiliary bundle was cut axially into strips of circa 0.2-mm thickness before being sequentially overlapped in placement. Roots in group II were restored with size 2 rigid prefabricated fiber dowels and luted with the light-cured cement provided by the manufacturer. After 24 hours of storage, axial tensile forces were applied to all luted dowels progressively to failure at 0.5 mm/min. Data were analyzed using a one-way analysis of variance (ANOVA) and the Bonferonni test. The mean axial resistance forces (standard deviation [SD]) for groups Ia, Ib, and II were not statistically different at 166 (49), 157 (36), and 151 (44) N, respectively (p > 0.05). There was no significant difference between the retention of the flexible fiber-bundle dowel system and that of the rigid prefabricated fiber dowel system. Decreasing the volume of luting cement around the flexible dowels did not have a significant effect on the axial retention of the restorations.
- 12 August 2008
- Published by Wiley in International Endodontic Journal
- Vol. 41 (9) , 816
A survey on the experience of UK endodontists and general dental practitioners in the management of intra-canal fractured endodontic files
- 12 August 2008
- Published by Wiley in International Endodontic Journal
- Vol. 41 (9) , 816
A survey on the experience of UK endodontists and general dental practitioners in the management of intra-canal fractured endodontic files
- 1 March 2003
- Vol. 34 (3) , 199-201
A comparison of the retention of tooth-colored posts.
The aim of this in vitro study was to compare the retention of five different esthetic post systems of similar dimensions in extracted teeth using titanium posts as controls. Sixty recently extracted single-rooted, caries-free teeth were sectioned horizontally and mounted in acrylic resin. The samples were randomly allocated into six groups of 10 for post preparation. Post space preparation was carried out according to the individual manufacturer's instructions. All posts were bonded using Panavia F. A 4-mm hollow, metal sleeve was luted over the free end of each post prior to mounting in a universal testing machine, and the forces required to dislodge the posts using a cross-head speed of 5 mm/min were recorded. It was found that the parallel-sided Lightposts were significantly more retentive than all of the other posts. Parapost Fibrewhite posts were more retentive than tapered Lightposts and Snowposts. There was no significant difference between the retention of stainless steel Paraposts and any of the other groups. Serrated parallel-sided stainless steel posts were no more retentive than either parallel-sided or tapered tooth-colored posts in this study. When all groups were considered, post dimension appeared to influence retention, with parallel-sided posts being more retentive than tapered posts.
- 1 March 2003
- Vol. 34 (3) , 199-201
A comparison of the retention of tooth-colored posts.
The aim of this in vitro study was to compare the retention of five different esthetic post systems of similar dimensions in extracted teeth using titanium posts as controls. Sixty recently extracted single-rooted, caries-free teeth were sectioned horizontally and mounted in acrylic resin. The samples were randomly allocated into six groups of 10 for post preparation. Post space preparation was carried out according to the individual manufacturer's instructions. All posts were bonded using Panavia F. A 4-mm hollow, metal sleeve was luted over the free end of each post prior to mounting in a universal testing machine, and the forces required to dislodge the posts using a cross-head speed of 5 mm/min were recorded. It was found that the parallel-sided Lightposts were significantly more retentive than all of the other posts. Parapost Fibrewhite posts were more retentive than tapered Lightposts and Snowposts. There was no significant difference between the retention of stainless steel Paraposts and any of the other groups. Serrated parallel-sided stainless steel posts were no more retentive than either parallel-sided or tapered tooth-colored posts in this study. When all groups were considered, post dimension appeared to influence retention, with parallel-sided posts being more retentive than tapered posts.
- Retracted
- 21 October 2002
- Published by Wiley
- No. 4
Pulp management for caries in adults: maintaining pulp vitality
- 21 October 2002
- Published by Wiley
- No. 4
RetractedPulp management for caries in adults: maintaining pulp vitality