DWDietmar Weng

Dietmar Weng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dietmar Weng has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 7 April 2009
      • Vol. 24  (1) , 31-7

    The effects of recombinant human growth/differentiation factor-5 (rhGDF-5) on bone regeneration around titanium dental implants in barrier membrane-protected defects: a pilot study in the mandible of beagle dogs.

    by Dietmar Weng, Sylke Poehling, Susanne Pippig, Matthias Bell, Ernst-Jürgen Richter, Otto Zuhr, Markus B Hürzeler

    This dog study sought to evaluate guided bone regeneration (GBR) in peri-implant defects following implantation of beta-tricalcium phosphate (beta-TCP) with and without osteoinductive recombinant human growth/differentiation factor-5 (rhGDF-5). In five beagle dogs, all mandibular premolars and the first molar were extracted. After 2 months, six buccolingual critical-size defects were created, and an implant was inserted into the center of each defect. One defect was filled with beta-TCP coated with rhGDF-5 (600 microg/g beta-TCP) and covered with a titanium-reinforced e-PTFE membrane (GDF group). A second defect received the same treatment, but pure uncoated beta-TCP was used (TCP group). A third defect was filled with beta-TCP mixed with autograft and not protected with a membrane (control group). The remaining three defects were filled with other biomaterials. After 2 months, total new bone area, regenerated bone height, and residual amount of beta-TCP were determined histomorphometrically. All implants osseointegrated. One membrane in each group became exposed. Mean new bone area for GDF, TCP, and control sites was 43.9 +/- 18.7 mm2, 32.3 +/- 16.1 mm2, and 13.1 +/- 4.0 mm2, respectively, with a significant difference between GDF and control groups. Mean regenerated bone height was 103.8 +/- 29.7%, 75.4 +/- 36.6%, and 67.2 +/- 19.1% for the GDF, TCP, and control groups, respectively. Mean residual matrix volumes were 25.9 +/- 13.6%, 30.0 +/- 13.0%, and 13.4 +/- 6.5%, respectively. Membrane protection of peri-implant defects filled with beta-TCP resulted in a stronger effect on bone regeneration, although this was not statistically significant. The most pronounced regenerative results were achieved in rhGDF-5/beta-TCP filled membrane-protected defects. Delivery of rhGDF-5 on beta-TCP might have the potential to enhance the results of GBR in peri-implant defects.


    • 1 February 2007
      • Vol. 27  (1) , 35-41

    Maxillary removable prostheses retained by telescopic crowns on two implants or two canines.

    by Dietmar Weng, Ernst-Jürgen Richter

    Precision telescopic attachments allow for rigid connection between removable prostheses and abutments. However, it is still unknown whether implants can bear similar long-term loading forces as teeth when telescopic crowns are used as retention devices. It was the aim of this prospective clinical study to observe maxillary removable partial dentures that were retained by telescopic crowns on two endosseous implants in the canine regions. In a control group, identical dentures were fabricated that were retained by telescopic crowns on the maxillary canines. The implant group consisted of 14 patients, and the control group included 8 patients. Mean observation time of the prostheses was 25.6 months. Radiographic bone levels and periodontal parameters did not reveal specific differences between the two groups. However, five implants failed, and there were no failures in the control group. Survival rates were 48.9% for the implant group and 100% for the control group, with a significant difference between the two groups. Within the limits of this study, it is concluded that the telescopic connection might be too rigid (thus delivering overloading) for two single implants in the canine region of the maxilla supporting a removable denture.


  • Osseotite® vs. machined surface in poor bone quality

    by Dietmar Weng, Marianne Hoffmeyer, Markus B. Hürzeler, Ernst‐Jürgen Richter

    Implant sites with low bone content have exhibited lower implant survival rates than dense bone areas. Alterations of the implant surface seem to influence the bone‐to‐implant contact rate and may have an impact on implant failure rates in such sites. It was the objective of this animal study to histomorphometrically compare two different implant surfaces in so‐called poor bone quality sites. All premolars on one side of the mandible were extracted in five fox hounds. After a healing time of 8 months, four screw‐type implants (two with a machined surface (ICE group) and two with a double acid‐etched (Osseotite®) surface (OSS group)) were inserted into the mandible. Upon insertion, the implant apex was located in the ‘hollow’ part of the dog mandible, where the bone content is low. After 4 months healing, histomorphometric evaluations were performed. All implants osseointegrated clinically and histologically. Periapical density measurements revealed similar bone contents in both groups (ICE 49.9±16.7%, OSS 52.2±8.4%; P>0.05). Despite these similar amounts of bone content in the apical area around the implant, the Osseotite® implant surface had a significantly higher bone‐to‐implant contact rate than the machined surface (OSS 62.9±12.4%, ICE 39.5±13.0%; P® surface can achieve a significantly higher bone‐to‐implant contact compared to a machined surface.


    • 20 June 2003
      • Vol. 18  (3) , 417-23

    A prospective multicenter clinical trial of 3i machined-surface implants: results after 6 years of follow-up.

    by Dietmar Weng, Zhimon Jacobson, Dennis Tarnow, Markus B Hürzeler, Ove Faehn, Farshid Sanavi, Pål Barkvoll, Renée M Stach

    In this prospective multicenter clinical study, 1,179 3i standard threaded and self-tapping implants were followed for up to 6 years and monitored according to established success criteria. A total of 493 patients (240 men and 253 women) with a mean age of 45.1 years at implant surgery were enrolled at 6 research centers after being screened for exclusion criteria. Implants were placed according to a 2-stage surgical protocol with a minimum of 4 months of submerged healing in the mandible and 6 months in the maxilla. Restorations included 633 prostheses, the majority of which were fixed partial dentures in the posterior mandible or maxilla or single-tooth replacements in the anterior maxilla. One hundred four implants (8.8%) did not meet success criteria and were designated as failures, and 222 implants (18.8%) were lost to follow-up. The cumulative success rate according to life table methods was 91.1% at 6 years. Sixty percent of the failed implants were short (< or = 10 mm long), and their cumulative success rate as a group at 6 years was 89.0%, compared to 93.1% for longer implants (P < .05). Thirty-three percent of all failures were implants placed in the posterior maxilla, for a 5-year cumulative success rate of 87.4%. It appears that limited bone dimensions and poor-quality bone have an impact on the performance of these machined-surface implants.


    • 1 September 2002
      • Vol. 33  (8) , 584-8

    Treatment of a juvenile patient with a maxillary all-ceramic resin-bonded fixed partial denture: a case report.

    by Dietmar Weng, Stefan Ries, Ernst-Jürgen Richter

    Treatment of juvenile patients with a missing maxillary incisor is difficult, because an implant cannot be placed until growth is completed. The other minimally invasive alternatives are also problematic: Removable dentures are rarely accepted by juvenile patients, and the conventional resin-bonded fixed partial denture often provides a poor esthetic result because the metal retainer causes the abutment teeth to lose their natural translucency and to become grayish. Moreover, the alveolar ridge defect makes it easy to identify the prosthesis in the pontic area. The present case report describes the prosthetic treatment of a juvenile patient who had lost a maxillary incisor to trauma. To avoid the disadvantages of conventional therapies, subepithelial connective tissue was grafted to reshape the alveolar ridge. The space was closed with an all-ceramic resin-bonded fixed partial denture.


    • 1 August 2002
      • Vol. 23  (8) , 695

    A meta-analysis evaluating the risk for implant failure in patients who smoke.

    by Crawford A Bain, Dietmar Weng, Alan Meltzer, Sean S Kohles, Renée M Stach

    Failure of dental implants to achieve osseointegration is often attributed to patient baseline variables, such as smoking. This meta-analysis examines outcomes of clinical studies that monitored the performance of machined-surfaced and Osseotite, implants; the analysis also isolates the effect of smoking. The implant data for the machined-surfaced implants are derived from three prospective multicenter studies (n = 2,614) and from six prospective studies (n = 2,274) for the Osseotite implants. All implant placement surgeries followed a two-stage surgical approach with an unloaded healing period of 4 to 6 months. An evaluation of the data sets (i.e., smokers vs nonsmokers) was first performed to determine the existence of imbalance in baseline variables, including patient demographics, bone quality, location, dimensions, and types of prostheses. Analysis of the distributions of these baseline variables showed similar proportionalities and therefore qualified the data sets for comparison of the cumulative success rates (CSR) of the implants on the basis of smoking. For the 2,117 nonsmoking, machined-surfaced implants, the 3-year CSR is 92.8%; for the 492 implants in the smoking group, the CSR is 93.5%. The 3-year CSR for 1,877 nonsmoking Osseotite implants is 98.4%; for the 397 smoking implants it is 98.7%. No difference is observed between the smoking groups and the nonsmoking groups in these patient populations. There is, however, a clinically relevant difference observed between the two implant types.


  • Contribution of the periosteum to bone formation in guided bone regeneration

    by Dietmar Weng, Markus B. Hürzeler, Carlos R. Quiñones, Angela Ohlms, Raul G. Caffesse

    The periosteum has been referred to as a protective barrier in the regeneration of bone defects. The objective of this study was to determine the contribution of periosteum as a natural barrier to bone formation in guided bone regeneration. Mucoperiosteal flaps were elevated bilaterally on the buccal aspect of the mandibular angle in 5 cynomolgus monkeys. Bleeding was induced by perforating the cortical bone. A hemispherical titanium mesh was fixed over the areas thus creating a void 5 mm in height between the mesh and the bone surface. On one side the mesh was covered with an ePTFE membrane (test side). The contralateral side did not receive further treatment (control side). After 4 month healing, histomorphometric analyses were used to determine the percentage of new bone in the void underneath the mesh, and the ratio between mineralized tissue and marrow spaces in new and old bone. The mean percentage of new bone tissue was 77.2±7.5% for the test sides and 68.6±8.4% for the control sides (P=0.018, t‐test). This new bone contained 80.0±3.6% mineralized tissue in the test group and 82.5±5.0% in the control group (P>0.05, t‐test). In both groups the newly formed bone exhibited significantly less mineralized tissue than the old bone (Pt‐test). It is concluded from this study that new bone formation was enhanced by the additional use of an ePTFE membrane under a periosteum‐lined mucoperiosteal flap when space maintenance was excluded as a critical factor.