Eric L. Brosha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eric L. Brosha has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Fernando H. Garzon
Los Alamos National Laboratory, Sensors and Electrochemical Devices Group, MPA-11, Los Alamos, New Mexico 87545, USA
5 shared publications- Rangachary Mukundan
Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
4 shared publications Rangachary Mukundan
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
3 shared publicationsAmanda S. Wu
Lawrence Livermore National Laboratory
2 shared publicationsChristopher J. Romero
Los Alamos National Laboratory
2 shared publications- Cortney R. Kreller
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2 shared publications
Latest Publications
- 25 October 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (10) , 1333-1344
(Invited) Field Trials Testing of Mixed Potential Electrochemical Hydrogen Safety Sensors at Commercial California Hydrogen Filling Stations
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, chemical stability across operating temperatures, and fast response time. Over a two-year period, sensors with two different working electrodes—tin-doped indium oxide and strontium doped lanthanum chromite—were deployed at hydrogen filling stations in the Los Angeles area. The sensors exhibit high baseline stability and excellent correlation with logged filling/release events, making these materials good candidates for applications requiring long-life, drift-free baseline operation, in which sensor calibrations and replacements are prohibitive.
- 25 October 2017
- Published by The Electrochemical Society in ECS Transactions
- Vol. 80 (10) , 1333-1344
(Invited) Field Trials Testing of Mixed Potential Electrochemical Hydrogen Safety Sensors at Commercial California Hydrogen Filling Stations
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, chemical stability across operating temperatures, and fast response time. Over a two-year period, sensors with two different working electrodes—tin-doped indium oxide and strontium doped lanthanum chromite—were deployed at hydrogen filling stations in the Los Angeles area. The sensors exhibit high baseline stability and excellent correlation with logged filling/release events, making these materials good candidates for applications requiring long-life, drift-free baseline operation, in which sensor calibrations and replacements are prohibitive.
- Open Access
- 7 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , B681-B689
Editors' Choice—Field Trials Testing of Mixed Potential Electrochemical Hydrogen Safety Sensors at Commercial California Hydrogen Filling Stations
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, and fast response time. Over a two-year period, sensors with tin-doped indium oxide and strontium doped lanthanum chromite electrodes were deployed at two stations in four field trials tests conducted in Los Angeles. The sensors documented the existence of hydrogen plumes ranging in concentration from 100 to as high as 2700 ppm in the area surrounding the dispenser, consistent with depressurization from 700 bar following vehicle refueling. As expected, the hydrogen concentration reported by the mixed potential sensors was influenced by wind direction. Baseline stability testing at a Chino, CA station showed no measureable baseline drift throughout 206 days of uninterrupted data acquisition. The high baseline stability, excellent correlation with logged fueling/depressurization events, and absence of false alarms suggest that the zirconia-based mixed potential sensor platform is a good candidate for protecting hydrogen infrastructure where frequent calibrations or sensor replacement to reduce the false alarm frequency have been shown to be cost prohibitive.
- 7 October 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , B681-B689
Open AccessEditors' Choice—Field Trials Testing of Mixed Potential Electrochemical Hydrogen Safety Sensors at Commercial California Hydrogen Filling Stations
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, and fast response time. Over a two-year period, sensors with tin-doped indium oxide and strontium doped lanthanum chromite electrodes were deployed at two stations in four field trials tests conducted in Los Angeles. The sensors documented the existence of hydrogen plumes ranging in concentration from 100 to as high as 2700 ppm in the area surrounding the dispenser, consistent with depressurization from 700 bar following vehicle refueling. As expected, the hydrogen concentration reported by the mixed potential sensors was influenced by wind direction. Baseline stability testing at a Chino, CA station showed no measureable baseline drift throughout 206 days of uninterrupted data acquisition. The high baseline stability, excellent correlation with logged fueling/depressurization events, and absence of false alarms suggest that the zirconia-based mixed potential sensor platform is a good candidate for protecting hydrogen infrastructure where frequent calibrations or sensor replacement to reduce the false alarm frequency have been shown to be cost prohibitive.
- 20 October 2016
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 3 (1) , 112-121
Response Characteristics of Stable Mixed-Potential NH3 Sensors in Diesel Engine Exhaust
- 20 October 2016
- Published by Springer Nature in Emission Control Science and Technology
- Vol. 3 (1) , 112-121
Response Characteristics of Stable Mixed-Potential NH3 Sensors in Diesel Engine Exhaust
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (1) , B180-B186
Measurement of H[sub 2]S Crossover Rates in Polymer Fuel Cell Membranes Using an Ion-Probe Technique
A sulfide antioxidant buffer solution was used to trap and concentrate trace quantities of H2SH2S that permeated through 50cm250cm2 samples of fuel cell Nafion 117, 212, and 112 membranes using a H2SH2S partial pressure difference up to 1000 ppm at room temperature. Experiments were conducted between 24 and 48 h to achieve sulfide ion concentrations high enough to be determined accurately by subsequent titration with Pb(NO3)2Pb(NO3)2 . In contrast to previous work, a special H2SH2S mixing system was employed to achieve reproducible delivery of H2SH2S concentrations throughout each experiment. The calculated rates of H2SH2S crossover, normalized for membrane area, thickness, and differential PH2SPH2S varied from as low as 7.58×10−107.58×10−10 to 4.65×10−9g/satmcm4.65×10−9g/satmcm depending on the type of Nafion sample and humidity conditions. Even low levels of humidification of the membrane and gases (saturated at 25°C25°C ) increased the crossover rate of H2SH2S in the Nafion materials. H2SH2S permeation through the electrolyte membrane negatively impacts the oxygen reduction rate occurring on the cathode and possibly causes an irreversible decrease in the overall fuel cell performance.
- 1 January 2010
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 157 (1) , B180-B186
Measurement of H[sub 2]S Crossover Rates in Polymer Fuel Cell Membranes Using an Ion-Probe Technique
A sulfide antioxidant buffer solution was used to trap and concentrate trace quantities of H2SH2S that permeated through 50cm250cm2 samples of fuel cell Nafion 117, 212, and 112 membranes using a H2SH2S partial pressure difference up to 1000 ppm at room temperature. Experiments were conducted between 24 and 48 h to achieve sulfide ion concentrations high enough to be determined accurately by subsequent titration with Pb(NO3)2Pb(NO3)2 . In contrast to previous work, a special H2SH2S mixing system was employed to achieve reproducible delivery of H2SH2S concentrations throughout each experiment. The calculated rates of H2SH2S crossover, normalized for membrane area, thickness, and differential PH2SPH2S varied from as low as 7.58×10−107.58×10−10 to 4.65×10−9g/satmcm4.65×10−9g/satmcm depending on the type of Nafion sample and humidity conditions. Even low levels of humidification of the membrane and gases (saturated at 25°C25°C ) increased the crossover rate of H2SH2S in the Nafion materials. H2SH2S permeation through the electrolyte membrane negatively impacts the oxygen reduction rate occurring on the cathode and possibly causes an irreversible decrease in the overall fuel cell performance.
- Open Access
- 1 January 2010
- Published by The Electrochemical Society in The Electrochemical Society Interface
- Vol. 19 (4) , 35-40
Chemical Sensors for Environmental Monitoring and Homeland Security
This article provides the basic concepts and classifications of chemical sensors and emphasizes the application of chemical sensors in the domains of environmental monitoring and homeland security. Chemical sensors have been comprehensively applied in the areas including chemical process, pharmaceutical, food, biomedical, environmental, security, industrial safety, clinical, indoor monitoring, etc. In terms of environmental monitoring, the article discusses two types of chemical sensors: Metal-oxide-based gas sensor systems and electrochemical mixed potential based gas sensor systems. For use in homeland security applications, electrochemical systems are described as promising due to their high selectivity, portability, a wide linear range, minimal space and power requirements combined with their ability to lower the deployment cost of sensors using mass production.
- 1 January 2010
- Published by The Electrochemical Society in The Electrochemical Society Interface
- Vol. 19 (4) , 35-40
Open AccessChemical Sensors for Environmental Monitoring and Homeland Security
This article provides the basic concepts and classifications of chemical sensors and emphasizes the application of chemical sensors in the domains of environmental monitoring and homeland security. Chemical sensors have been comprehensively applied in the areas including chemical process, pharmaceutical, food, biomedical, environmental, security, industrial safety, clinical, indoor monitoring, etc. In terms of environmental monitoring, the article discusses two types of chemical sensors: Metal-oxide-based gas sensor systems and electrochemical mixed potential based gas sensor systems. For use in homeland security applications, electrochemical systems are described as promising due to their high selectivity, portability, a wide linear range, minimal space and power requirements combined with their ability to lower the deployment cost of sensors using mass production.
- 1 January 2008
- Published by The Electrochemical Society in Electrochemical and Solid-State Letters
- Vol. 11 (12) , J92-J95
YSZ-Based Mixed Potential Sensors for the Detection of Explosives
A zirconia-based mixed potential sensor utilizing dense lanthanum chromite and Pt electrodes and porous yttria-stabilized zirconia (YSZ) electrolyte was used in an alternating HC mode (unbiased) and total mode ( bias current) to detect the HC and deflagration remnants of a nitroglycerin/nitrocellulose propellant (Bullseye), ammonium nitrate and fuel oil, blackpowder, and urea (a high nitrogen content fertilizer). Unique HC and sensor responses taken together with sufficient sensitivity to detect microgram quantities of Bullseye, directly and via capture of trace residue by swiping contaminated surfaces, suggest that detection and discrimination of high explosives using mixed-potential sensors is possible.
- 1 January 2008
- Published by The Electrochemical Society in Electrochemical and Solid-State Letters
- Vol. 11 (12) , J92-J95
YSZ-Based Mixed Potential Sensors for the Detection of Explosives
A zirconia-based mixed potential sensor utilizing dense lanthanum chromite and Pt electrodes and porous yttria-stabilized zirconia (YSZ) electrolyte was used in an alternating HC mode (unbiased) and total mode ( bias current) to detect the HC and deflagration remnants of a nitroglycerin/nitrocellulose propellant (Bullseye), ammonium nitrate and fuel oil, blackpowder, and urea (a high nitrogen content fertilizer). Unique HC and sensor responses taken together with sufficient sensitivity to detect microgram quantities of Bullseye, directly and via capture of trace residue by swiping contaminated surfaces, suggest that detection and discrimination of high explosives using mixed-potential sensors is possible.
- 7 December 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 119 (2) , 398-408
Mixed potential NOx sensors using thin film electrodes and electrolytes for stationary reciprocating engine type applications
- 7 December 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 119 (2) , 398-408
Mixed potential NOx sensors using thin film electrodes and electrolytes for stationary reciprocating engine type applications
- 30 January 2004
- Published by Elsevier in Solid State Ionics
- Vol. 166 (3-4) , 425-440
Techniques for the thin film growth of La1−xSrxCrO3 for solid state ionic devices
- 30 January 2004
- Published by Elsevier in Solid State Ionics
- Vol. 166 (3-4) , 425-440
Techniques for the thin film growth of La1−xSrxCrO3 for solid state ionic devices
- 1 November 2002
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 87 (1) , 47-57
Mixed potential sensors using lanthanum manganate and terbium yttrium zirconium oxide electrodes
- 1 November 2002
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 87 (1) , 47-57
Mixed potential sensors using lanthanum manganate and terbium yttrium zirconium oxide electrodes
- 1 June 1998
- Published by Elsevier in Solid State Ionics
- Vol. 109 (1-2) , 73-80
Amperometric oxygen sensors based on dense Tb–Y–Zr–O electrodes
- 1 June 1998
- Published by Elsevier in Solid State Ionics
- Vol. 109 (1-2) , 73-80
Amperometric oxygen sensors based on dense Tb–Y–Zr–O electrodes