Onofrio Resta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Onofrio Resta has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Maria Pia Foschino Barbaro
Department of Medical and Surgical Sciences, University of Foggia, 71122 Foggia, Italy
8 shared publications - Pierluigi Carratù
Internal Medicine “A. Murri”, University of Bari, 70121 Bari, Italy
8 shared publications - Donato Lacedonia
Department of Medical and Surgical Sciences, University of Foggia, 71122 Foggia, Italy
4 shared publications - Mauro Maniscalco
Istituti Clinici Scientifici Maugeri IRCCS, Pulmonary Rehabilitation Unit of Telese Terme Institute, 82037 Telese Terme, Italy
3 shared publications S Talamo
3 shared publications- Cristina Scoditti
Institute of Pulmonary Disease, University of Bari, Bari, Italy
2 shared publications
Latest Publications
- Open Access
- 7 September 2017
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 2 (17)
Correction of intermittent hypoxia reduces inflammation in obese subjects with obstructive sleep apnea
BACKGROUND . In obese subjects with obstructive sleep apnea (OSA), chronic intermittent hypoxia (CIH) may be linked to systemic and adipose tissue inflammation. METHODS . We obtained abdominal subcutaneous adipose tissue biopsies from OSA and non-OSA obese (BMI > 35) subjects at baseline and after 24 weeks (T1) of weight-loss intervention plus continuous positive airway pressure (c-PAP) or weight-loss intervention alone, respectively. OSA subjects were grouped according to good (therapeutic) or poor (subtherapeutic) adherence to c-PAP. RESULTS . At baseline, anthropometric and metabolic parameters, serum cytokines, and adipose tissue mRNA levels of obesity-associated chemokines and inflammatory markers were not different in OSA and non-OSA subjects. At T1, body weight was significantly reduced in all groups. Serum concentrations of IL-2, IL-4, IL-6, MCP-1, PDGF β , and VEGF α were reduced by therapeutic c-PAP in OSA subjects and remained unaltered in non-OSA and subtherapeutic c-PAP groups. Similarly, adipose tissue mRNA levels of macrophage-specific (CD68, CD36) and ER stress (ATF4, CHOP, ERO-1) gene markers, as well as of IL-6, PDGF β , and VEGF α , were decreased only in the therapeutic c-PAP group. CONCLUSION . CIH does not represent an additional factor increasing systemic and adipose tissue inflammation in morbid obesity. However, in subjects with OSA, an effective c-PAP therapy improves systemic and obesity-associated inflammatory markers. FUNDING . Ministero dell’Università e della Ricerca and Progetti di Rilevante Interesse Nazionale.
- 7 September 2017
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 2 (17)
Open AccessCorrection of intermittent hypoxia reduces inflammation in obese subjects with obstructive sleep apnea
BACKGROUND . In obese subjects with obstructive sleep apnea (OSA), chronic intermittent hypoxia (CIH) may be linked to systemic and adipose tissue inflammation. METHODS . We obtained abdominal subcutaneous adipose tissue biopsies from OSA and non-OSA obese (BMI > 35) subjects at baseline and after 24 weeks (T1) of weight-loss intervention plus continuous positive airway pressure (c-PAP) or weight-loss intervention alone, respectively. OSA subjects were grouped according to good (therapeutic) or poor (subtherapeutic) adherence to c-PAP. RESULTS . At baseline, anthropometric and metabolic parameters, serum cytokines, and adipose tissue mRNA levels of obesity-associated chemokines and inflammatory markers were not different in OSA and non-OSA subjects. At T1, body weight was significantly reduced in all groups. Serum concentrations of IL-2, IL-4, IL-6, MCP-1, PDGF β , and VEGF α were reduced by therapeutic c-PAP in OSA subjects and remained unaltered in non-OSA and subtherapeutic c-PAP groups. Similarly, adipose tissue mRNA levels of macrophage-specific (CD68, CD36) and ER stress (ATF4, CHOP, ERO-1) gene markers, as well as of IL-6, PDGF β , and VEGF α , were decreased only in the therapeutic c-PAP group. CONCLUSION . CIH does not represent an additional factor increasing systemic and adipose tissue inflammation in morbid obesity. However, in subjects with OSA, an effective c-PAP therapy improves systemic and obesity-associated inflammatory markers. FUNDING . Ministero dell’Università e della Ricerca and Progetti di Rilevante Interesse Nazionale.
- Open Access
- 29 July 2015
- Published by European Publishing in Tobacco Induced Diseases
- Vol. 13 (1) , 20
Smoking Habit in Severe Obese after bariatric procedures
Bariatric procedures provide an effective means of short term weight loss and sustained weight control for the morbidly obese. The effect of bariatric procedures on smoking habit in obese subjects is not well known. Therefore, we examined the short term effect of bariatric surgery on smoking habit of severe obese patients up to 12 months from the intervention. Smoking habit was assessed in a cohort of 78 morbid smoking obese patients followed at our clinic for bariatric procedures. They underwent non surgical intra-gastric balloon (IB) or surgical procedures such as lap–band laparoscopic surgery (LAGB) or sleeve gastrectomy/gastric by-pass (SPG). Subjects were administered a written questionnaire about their smoking habit before and 3, 6 and 12 months after the procedures. No differences were found among the three groups at 6 and 12 months after the procedures (IB 21 %, LAGB 6 %, SPG 5 %; and IB 14 %, LAGB 3 %, SPG 5 %). Only after 3 months, the rate of quitting of the IB group was higher than LAGB and SPG groups (36 %, 6 % and 5 %, respectively; p = 0.02). Bariatric procedures have no effects on smoking habit of moderate-to-heavy smoker severe obese patients. The use of other traditional smoking cessation methods in patients undergone to bariatric procedures should be implemented.
- 29 July 2015
- Published by European Publishing in Tobacco Induced Diseases
- Vol. 13 (1) , 20
Open AccessSmoking Habit in Severe Obese after bariatric procedures
Bariatric procedures provide an effective means of short term weight loss and sustained weight control for the morbidly obese. The effect of bariatric procedures on smoking habit in obese subjects is not well known. Therefore, we examined the short term effect of bariatric surgery on smoking habit of severe obese patients up to 12 months from the intervention. Smoking habit was assessed in a cohort of 78 morbid smoking obese patients followed at our clinic for bariatric procedures. They underwent non surgical intra-gastric balloon (IB) or surgical procedures such as lap–band laparoscopic surgery (LAGB) or sleeve gastrectomy/gastric by-pass (SPG). Subjects were administered a written questionnaire about their smoking habit before and 3, 6 and 12 months after the procedures. No differences were found among the three groups at 6 and 12 months after the procedures (IB 21 %, LAGB 6 %, SPG 5 %; and IB 14 %, LAGB 3 %, SPG 5 %). Only after 3 months, the rate of quitting of the IB group was higher than LAGB and SPG groups (36 %, 6 % and 5 %, respectively; p = 0.02). Bariatric procedures have no effects on smoking habit of moderate-to-heavy smoker severe obese patients. The use of other traditional smoking cessation methods in patients undergone to bariatric procedures should be implemented.
- 6 January 2011
- Published by Springer Nature in Sleep and Breathing
- Vol. 16 (1) , 95-100
Predictive equations for CPAP titration in OSAS patients
Continuous positive airway pressure (CPAP) is the elective treatment of obstructive sleep apnea. The therapeutic level of CPAP is generally established by manual titration or an auto CPAP device, but an alternative way involves the use of predictive formulas. The aim of the present study was to test the difference between mathematical equations and CPAP or auto CPAP in terms of therapeutic pressure.
- 6 January 2011
- Published by Springer Nature in Sleep and Breathing
- Vol. 16 (1) , 95-100
Predictive equations for CPAP titration in OSAS patients
Continuous positive airway pressure (CPAP) is the elective treatment of obstructive sleep apnea. The therapeutic level of CPAP is generally established by manual titration or an auto CPAP device, but an alternative way involves the use of predictive formulas. The aim of the present study was to test the difference between mathematical equations and CPAP or auto CPAP in terms of therapeutic pressure.
- Open Access
- 10 March 2009
- Published by Springer Nature in Orphanet Journal of Rare Diseases
- Vol. 4 (1) , 10
Early treatment with noninvasive positive pressure ventilation prolongs survival in Amyotrophic Lateral Sclerosis patients with nocturnal respiratory insufficiency
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease, which rapidly leads to chronic respiratory failure requiring mechanical ventilation. Currently, forced vital capacity (FVC) < 50% is considered as physiologic marker for admitting patients to Noninvasive Positive Pressure Ventilation (NPPV) intervention, although it has been recently shown the median survival of patients with baseline FVC < 75% much shorter than median survival of patients with baseline FVC > 75%, independently by any treatment.
- 10 March 2009
- Published by Springer Nature in Orphanet Journal of Rare Diseases
- Vol. 4 (1) , 10
Open AccessEarly treatment with noninvasive positive pressure ventilation prolongs survival in Amyotrophic Lateral Sclerosis patients with nocturnal respiratory insufficiency
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease, which rapidly leads to chronic respiratory failure requiring mechanical ventilation. Currently, forced vital capacity (FVC) < 50% is considered as physiologic marker for admitting patients to Noninvasive Positive Pressure Ventilation (NPPV) intervention, although it has been recently shown the median survival of patients with baseline FVC < 75% much shorter than median survival of patients with baseline FVC > 75%, independently by any treatment.
- Open Access
- 26 September 2008
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 8 (1) , 20
Exhaled and arterial levels of endothelin-1 are increased and correlate with pulmonary systolic pressure in COPD with pulmonary hypertension
Endothelin-1 (ET-1) and Nitric Oxide (NO) are crucial mediators for establishing pulmonary artery hypertension (PAH). We tested the hypothesis that their imbalance might also occur in COPD patients with PAH.
- 26 September 2008
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 8 (1) , 20
Open AccessExhaled and arterial levels of endothelin-1 are increased and correlate with pulmonary systolic pressure in COPD with pulmonary hypertension
Endothelin-1 (ET-1) and Nitric Oxide (NO) are crucial mediators for establishing pulmonary artery hypertension (PAH). We tested the hypothesis that their imbalance might also occur in COPD patients with PAH.
- Open Access
- 30 March 2007
- Published by PAGEPress Publications in Monaldi Archives for Chest Disease
- Vol. 67 (1) , 6-9
Long term evaluation of mental fatigue by Maastricht Questionnaire in patients with OSAS treated with CPAP
Background. Patients with obstructive sleep apnoea syndrome (OSAS) suffer from disrupted sleep. Impaired nightly sleep leads to increase physical and mental fatigue. The effect of long term continuous positive airway pressure (CPAP) on mental fatigue in OSAS patients, assessed by Maastricht Questionnaire (MQ), has not been investigated yet. Methods. In order to evaluate the role of CPAP in improving mental fatigue of patients with OSAS, we studied 35 patients (26 males, age <65 years at the time of the diagnosis) affected by OSAS, established by polysomnography (PSG). Patients were divided into two groups; 19 subjects (15 males), who refused CPAP therapy, and 16 patients (11 males) well matched for sex, age, body mass index (BMI), neck circumference, duration of follow up, and severity of disease, who had been treated with CPAP for at least two years. Results. All patients had severe OSAS with Respiratory Disturbance Index (RDI), of 48±20.9 (range 22-90) and 61.48±18.6 (range 34-101) respectively, for group one (untreated patients) and group two (CPAP treatment). In addition, all patients had severe impairment of mental fatigue and of daytime sleepiness, demonstrated by high values of MQ score (32.17±15.33 and 37.36±12.4, respectively) and Epworth Sleepiness Scale (ESS) (14.21±4.77 and 15.06±6.07 respectively). There was no statistical significant difference in the group one at baseline and after follow- up, in terms of BMI, MQ score, ESS, and RDI. In the CPAP group (group two), the patients reported a significant improvement of the quality of their mental health (MQ 37.36±12.4 vs. 16.41±9.02; p<0.0001) and sleepiness (ESS 15.06±6.07 vs. 4.13±3.93; p<0.0001) with a stable BMI. There was significant correlation between the severity of sleep apnoea, expressed as RDI, and MQ at admission compared to at the end of follow-up (r=0.4, p<0.05). Conclusions. This study demonstrates an evident deterioration of mental fatigue in patients with OSAS, directly correlated to the severity of nocturnal disorder breathing; however supports the hypothesis that long term CPAP therapy significantly improves sleepiness and mental fatigue.
- 30 March 2007
- Published by PAGEPress Publications in Monaldi Archives for Chest Disease
- Vol. 67 (1) , 6-9
Open AccessLong term evaluation of mental fatigue by Maastricht Questionnaire in patients with OSAS treated with CPAP
Background. Patients with obstructive sleep apnoea syndrome (OSAS) suffer from disrupted sleep. Impaired nightly sleep leads to increase physical and mental fatigue. The effect of long term continuous positive airway pressure (CPAP) on mental fatigue in OSAS patients, assessed by Maastricht Questionnaire (MQ), has not been investigated yet. Methods. In order to evaluate the role of CPAP in improving mental fatigue of patients with OSAS, we studied 35 patients (26 males, age <65 years at the time of the diagnosis) affected by OSAS, established by polysomnography (PSG). Patients were divided into two groups; 19 subjects (15 males), who refused CPAP therapy, and 16 patients (11 males) well matched for sex, age, body mass index (BMI), neck circumference, duration of follow up, and severity of disease, who had been treated with CPAP for at least two years. Results. All patients had severe OSAS with Respiratory Disturbance Index (RDI), of 48±20.9 (range 22-90) and 61.48±18.6 (range 34-101) respectively, for group one (untreated patients) and group two (CPAP treatment). In addition, all patients had severe impairment of mental fatigue and of daytime sleepiness, demonstrated by high values of MQ score (32.17±15.33 and 37.36±12.4, respectively) and Epworth Sleepiness Scale (ESS) (14.21±4.77 and 15.06±6.07 respectively). There was no statistical significant difference in the group one at baseline and after follow- up, in terms of BMI, MQ score, ESS, and RDI. In the CPAP group (group two), the patients reported a significant improvement of the quality of their mental health (MQ 37.36±12.4 vs. 16.41±9.02; p<0.0001) and sleepiness (ESS 15.06±6.07 vs. 4.13±3.93; p<0.0001) with a stable BMI. There was significant correlation between the severity of sleep apnoea, expressed as RDI, and MQ at admission compared to at the end of follow-up (r=0.4, p<0.05). Conclusions. This study demonstrates an evident deterioration of mental fatigue in patients with OSAS, directly correlated to the severity of nocturnal disorder breathing; however supports the hypothesis that long term CPAP therapy significantly improves sleepiness and mental fatigue.
- 9 June 2005
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 35 (6) , 404-409
Early and late failure of noninvasive ventilation in chronic obstructive pulmonary disease with acute exacerbation
Background Despite recent encouraging results, the use of noninvasive ventilation (NIV) in the management of acute exacerbations in chronic obstructive pulmonary disease (COPD), complicated by acute respiratory failure (ARF), is not always successful. Failure of NIV may require an immediate intubation after a few hours (usually 1–3) of ventilation (‘early failure’) or may result in clinical deterioration (one or more days later) after an initial improvement of blood gas tension and general conditions (‘late failure’).Materials and methods We enrolled 122 patients affected by COPD complicated by ARF, and treated with NIV. The schedule of NIV provided sessions of 2–6 h twice daily.Results Ninety‐nine (81%) patients showed a progressive improvement of the clinical parameters and were discharged. Among the remaining 23 patients, 13 had an early failure and 10 had a late failure. In the ‘success’ group and ‘late failure’ groups we found after an increase of pH 2 h of NIV (from 7·31 ± 0·05 to 7·38 ± 0·04 P < 0·001 and from 7·29 ± 0·03 to 7·36 ± 0·02 P < 0·001, respectively) and a decrease of PaCO2 (from 80·93 ± 9·79 to 66·48 ± 5·95 P < 0·001 and from 85·96 ± 10·77 to 76·41 ± 11·02 P < 0·001, respectively). After 2 h of NIV in the ‘late failure’ group there were no significant changes in terms of pH (from 7·20 ± 0·10 to 7·28 ± 0·06) nor PaCO2 (from 92·86 ± 35·49 to 93·68 ± 23·68). The ‘early failure’ group had different characteristics and, owing to more severe conditions, the value of pH, of Glasgow Coma Score, and Apache II Score were the best predictors of the failure; while, among the complications on admission, metabolic alterations were the only independently significant predictor.Conclusions Our study confirms that NIV may be useful to avoid intubation in approximately 80% of patients with COPD complicated by moderate‐severe hypercapnic respiratory failure.
- 9 June 2005
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 35 (6) , 404-409
Early and late failure of noninvasive ventilation in chronic obstructive pulmonary disease with acute exacerbation
Background Despite recent encouraging results, the use of noninvasive ventilation (NIV) in the management of acute exacerbations in chronic obstructive pulmonary disease (COPD), complicated by acute respiratory failure (ARF), is not always successful. Failure of NIV may require an immediate intubation after a few hours (usually 1–3) of ventilation (‘early failure’) or may result in clinical deterioration (one or more days later) after an initial improvement of blood gas tension and general conditions (‘late failure’).Materials and methods We enrolled 122 patients affected by COPD complicated by ARF, and treated with NIV. The schedule of NIV provided sessions of 2–6 h twice daily.Results Ninety‐nine (81%) patients showed a progressive improvement of the clinical parameters and were discharged. Among the remaining 23 patients, 13 had an early failure and 10 had a late failure. In the ‘success’ group and ‘late failure’ groups we found after an increase of pH 2 h of NIV (from 7·31 ± 0·05 to 7·38 ± 0·04 P < 0·001 and from 7·29 ± 0·03 to 7·36 ± 0·02 P < 0·001, respectively) and a decrease of PaCO2 (from 80·93 ± 9·79 to 66·48 ± 5·95 P < 0·001 and from 85·96 ± 10·77 to 76·41 ± 11·02 P < 0·001, respectively). After 2 h of NIV in the ‘late failure’ group there were no significant changes in terms of pH (from 7·20 ± 0·10 to 7·28 ± 0·06) nor PaCO2 (from 92·86 ± 35·49 to 93·68 ± 23·68). The ‘early failure’ group had different characteristics and, owing to more severe conditions, the value of pH, of Glasgow Coma Score, and Apache II Score were the best predictors of the failure; while, among the complications on admission, metabolic alterations were the only independently significant predictor.Conclusions Our study confirms that NIV may be useful to avoid intubation in approximately 80% of patients with COPD complicated by moderate‐severe hypercapnic respiratory failure.
- Open Access
- 1 January 2005
- Published by Wiley in Canadian Respiratory Journal
- Vol. 12 (8) , 437-439
A Case of Cryptogenic Organizing Pneumonia Occurring in Crohn’s Disease
A 29 year‐old‐man with Crohn′s disease, who developed diffuse pulmonary infiltrates and hypoxemia two months following oral administration of mesalazine, was examined. Clinical findings and computed tomography were suggestive of, and lung histology was diagnostic of, bronchiolitis obliterans organizing pneumonia, also known as cryptogenic organizing pneumonia. Although the data did not allow for definitive conclusions, they did suggest that the pulmonary disease was an extraintestinal manifestation of Crohn′s disease, rather than an adverse reaction to mesalazine. In fact, the patient showed clinical, radiological and functional improvements, despite the treatment with mesalazine and the withdrawal of steroid therapy.
- 1 January 2005
- Published by Wiley in Canadian Respiratory Journal
- Vol. 12 (8) , 437-439
Open AccessA Case of Cryptogenic Organizing Pneumonia Occurring in Crohn’s Disease
A 29 year‐old‐man with Crohn′s disease, who developed diffuse pulmonary infiltrates and hypoxemia two months following oral administration of mesalazine, was examined. Clinical findings and computed tomography were suggestive of, and lung histology was diagnostic of, bronchiolitis obliterans organizing pneumonia, also known as cryptogenic organizing pneumonia. Although the data did not allow for definitive conclusions, they did suggest that the pulmonary disease was an extraintestinal manifestation of Crohn′s disease, rather than an adverse reaction to mesalazine. In fact, the patient showed clinical, radiological and functional improvements, despite the treatment with mesalazine and the withdrawal of steroid therapy.
- Open Access
- 30 September 2004
- Published by PAGEPress Publications
- Vol. 61 (3) , 153-6
Effects of fixed compared to automatic CPAP on sleep in Obstructive Sleep Apnoea Syndrome
Background: Automatic CPAP has been developed to improve CPAP efficiency and compliance. Continually matching the effective pressure may be associated to more frequent arousals that could disturb sleep. The aim of the present study was to compare sleep architecture after one month’s home therapy with CPAP or with an AutoCPAP device. Methods: Twenty OSAS patients (18 M / 2 F) after polysomnographic study with CPAP titration received either an automatic (AutoSet T, ResMed, Sydney, Australia) or a fixed level CPAP machine in a random, single blind fashion for one month. At the end of the home treatment period polysomnography was repeated while CPAP was administered by the same machine used at home. Results: There was no significant difference between groups in terms of age (50.0 vs 45.5, NS), sex, BMI (38.3 vs 35.1, NS), RDI (45.4 vs 48.0, NS), and CPAP effective level (9.8 vs 10.8, NS). After one month of therapy the correction of sleep respiratory disturbances and of sleep structure was satisfactory in both groups. No difference in any polysomnographic variable or in subjective sleepiness was found at re-evaluation. Conclusions: The results of this study demonstrate that on average CPAP administered by a fixed CPAP machine and by the AutoSet T autoCPAP device has similar effects in improving respiratory function during sleep, nocturnal sleep architecture, and subjective daytime sleepiness after a one-month therapy. As autoCPAP devices are more expensive than fixed CPAP machines, their prescription should be considered only after a clear demonstration of an increase in compliance to treatment by these devices.
- 30 September 2004
- Published by PAGEPress Publications
- Vol. 61 (3) , 153-6
Open AccessEffects of fixed compared to automatic CPAP on sleep in Obstructive Sleep Apnoea Syndrome
Background: Automatic CPAP has been developed to improve CPAP efficiency and compliance. Continually matching the effective pressure may be associated to more frequent arousals that could disturb sleep. The aim of the present study was to compare sleep architecture after one month’s home therapy with CPAP or with an AutoCPAP device. Methods: Twenty OSAS patients (18 M / 2 F) after polysomnographic study with CPAP titration received either an automatic (AutoSet T, ResMed, Sydney, Australia) or a fixed level CPAP machine in a random, single blind fashion for one month. At the end of the home treatment period polysomnography was repeated while CPAP was administered by the same machine used at home. Results: There was no significant difference between groups in terms of age (50.0 vs 45.5, NS), sex, BMI (38.3 vs 35.1, NS), RDI (45.4 vs 48.0, NS), and CPAP effective level (9.8 vs 10.8, NS). After one month of therapy the correction of sleep respiratory disturbances and of sleep structure was satisfactory in both groups. No difference in any polysomnographic variable or in subjective sleepiness was found at re-evaluation. Conclusions: The results of this study demonstrate that on average CPAP administered by a fixed CPAP machine and by the AutoSet T autoCPAP device has similar effects in improving respiratory function during sleep, nocturnal sleep architecture, and subjective daytime sleepiness after a one-month therapy. As autoCPAP devices are more expensive than fixed CPAP machines, their prescription should be considered only after a clear demonstration of an increase in compliance to treatment by these devices.
- Open Access
- 1 January 2003
- Published by Down Syndrome Education International in Down Syndrome Research and Practice
- Vol. 8 (3) , 115-120
Sleep related breathing disorders in adults with Down syndrome
Background. While the prevalence of obstructive sleep apnoea syndrome among children with Down syndrome is reported to vary from 30 to 50%, the nocturnal respiratory patterns of adults with Down syndrome is not well known. Objectives. The aim of this study is to evaluate sleep related breathing disorders in a sample of adults with Down syndrome. Methods. We studied the nocturnal respiratory patterns of 6 adults with Down syndrome, aged 28 to 53 years. All participants were monitored for 8 hours using a 12 channel polysomnograph. Respiratory events (apnoeic and hypopnoeic) were classified as obstructive or central, in relation to the presence or the absence of paradoxical breathing. Results. All participants had respiratory pauses during sleep. 5 of them had an apnoea hypopnoea index >10, justifying the diagnosis of sleep apnoea syndrome. About 85% of the respiratory events were apnoeic, the others being hypopnoeic. Among all the respiratory events 89.2% were obstructive, whereas only 10.8% were central. The central events were almost always organised in very low and regular sequences and respiration frequently showed a true periodic pattern, consisting of short periods of augmented breath followed by central events causing oxygen desaturation. Conclusions. According to the literature and in conjunction with the current study's results it could be hypothesised that the nocturnal respiratory pattern of adults with Down syndrome depends on several pathogenetic factors such as age, severity of upper airway abnormalities, body mass index (BMI), other pathological conditions and age related brainstem dysfunction.
- 1 January 2003
- Published by Down Syndrome Education International in Down Syndrome Research and Practice
- Vol. 8 (3) , 115-120
Open AccessSleep related breathing disorders in adults with Down syndrome
Background. While the prevalence of obstructive sleep apnoea syndrome among children with Down syndrome is reported to vary from 30 to 50%, the nocturnal respiratory patterns of adults with Down syndrome is not well known. Objectives. The aim of this study is to evaluate sleep related breathing disorders in a sample of adults with Down syndrome. Methods. We studied the nocturnal respiratory patterns of 6 adults with Down syndrome, aged 28 to 53 years. All participants were monitored for 8 hours using a 12 channel polysomnograph. Respiratory events (apnoeic and hypopnoeic) were classified as obstructive or central, in relation to the presence or the absence of paradoxical breathing. Results. All participants had respiratory pauses during sleep. 5 of them had an apnoea hypopnoea index >10, justifying the diagnosis of sleep apnoea syndrome. About 85% of the respiratory events were apnoeic, the others being hypopnoeic. Among all the respiratory events 89.2% were obstructive, whereas only 10.8% were central. The central events were almost always organised in very low and regular sequences and respiration frequently showed a true periodic pattern, consisting of short periods of augmented breath followed by central events causing oxygen desaturation. Conclusions. According to the literature and in conjunction with the current study's results it could be hypothesised that the nocturnal respiratory pattern of adults with Down syndrome depends on several pathogenetic factors such as age, severity of upper airway abnormalities, body mass index (BMI), other pathological conditions and age related brainstem dysfunction.