MNMadhu K. Nair

Madhu K. Nair

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Madhu K. Nair has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy of tuned aperture computed tomography in the diagnosis of radicular fractures in non-restored maxillary anterior teeth--an in vitro study.

    by M K Nair, U P Nair, H-G Gröndahl, R L Webber

    OBJECTIVES: This study compared the accuracy of three radiographic imaging modalities for the detection of artificially induced radicular fractures on maxillary anterior teeth. METHODS: Fractures were induced in 28 of 54 maxillary incisors in 15 cadaver specimens using a distally directed force. Radiographs evaluated included conventional two-dimensional direct digital radiographs (DDI), unprocessed Tuned Aperture Computed Tomography (TACT-U) and iteratively restored TACT (TACT-IR). Eight observers recorded their findings using a five-point confidence-rating scale. Receiver Operating Characteristic (ROC) analyses were done, followed by ANOVA to test for significant effects of observers, imaging modality and fracture location. Post hoc tests were carried out in instances where ANOVA indicated significance. RESULTS: The areas under the ROC-curves (A(z)) were, respectively: DDI: 0.53; TACT-U: 0.83 and TACT-IR: 0.97. TACT-IR and TACT-U performed significantly better than DDI (P < 0.001) with TACT-IR providing a higher detection accuracy than TACT-U (P < 0.033). A difference in detection accuracy was also noted based on fracture location (P < 0.001). Tukey's post hoc analyses revealed that fractures extending beyond the middle third of the root were more accurately detected. Inter-observer agreement was 0.68, and intra-examiner agreement, 0.87 (kappa analysis). CONCLUSIONS: TACT performed significantly better than direct digital images in detecting trauma-induced radicular fractures in unrestored, maxillary anterior teeth.


  • Detection of artificially induced vertical radicular fractures using Tuned Aperture Computed Tomography

    by Madhu K. Nair, Uma Devi P. Nair, Hans‐Göran Gröndahl, Richard L. Webber, James A. Wallace

    This study compared the accuracy of three imaging modalities for the detection of artificially induced vertical root fractures (VRF) on teeth in cadaver mandibles. Fifty‐four single‐rooted, endodontically treated mandibular teeth being prepared to carry posts were evaluated using direct digital radiography (DDI) with a Schick sensor, unprocessed Tuned Aperture Computed Tomography® (TACT‐U) images and iteratively restored TACT (TACT‐IR) images. Twenty‐eight of these teeth had been subjected to fracture induction using an apically driven force. Nine basis images were used for each TACT image generation. Eight observers used a five‐point confidence rating scale to record the confidence with which they considered a fracture to be present or not. Sensitivity and specificity values were computed and receiver operating characteristic (ROC) curves were generated. The areas under the curves (Az) used as an indication of the diagnostic accuracy of the imaging system were as follows: DDI: 0.37; TACT‐U: 0.77 and TACT‐IR: 0.81. DDI was significantly inferior to the TACT modalities. Differences in detection efficacy based on observers and observation sessions were noted on ANOVA and post‐hoc Tukey's tests. This study indicates that TACT is the imaging modality of choice for VRF in endodontically treated teeth.


  • An in–vitro Evaluation of Kodak Insight and Ektaspeed Plus Film with a CMOS Detector for Natural Proximal Caries: ROC Analysis

    by M.K. Nair, U.P. Nair

    This study compared the diagnostic efficacy of Kodak Ektaspeed Plus film, Kodak Insight film, a newly introduced E/F–speed film, and Schick CMOS–APS digital sensor, with respect to caries detection in 92 proximal surfaces of extracted unrestored teeth, 51 of which were carious. Ground truth was evaluated histologically and the lesions classified as enamel or dentinal. Eight observers read the radiographs using a five–point confidence rating scale to record their diagnoses. Analyses using receiver operating characteristic curves revealed the areas under each curve that indicated the diagnostic accuracy (Ektaspeed Plus – 0.760, Insight – 0.778 and CMOS–APS sensor – 0.732). ANOVA revealed significant differences with respect to caries depth (p<0.031) and observers (p<0.0001). Weighted kappa analyses indicated moderate to substantial inter– and intra–observer agreement (0.42 and 0.66, respectively). The results suggest that none of the imaging modalities evaluated in this study differed in their diagnostic capabilities with respect to proximal decay detection and that the Insight film which was used with 20% less radiation exposure than Ektaspeed Plus film was as good as the other two sensors for this purpose.


  • Tuned Aperture Computed Tomography to Evaluate Osseous Healing

    by M.K. Nair, A. Seyedain, S. Agarwal, R.L. Webber, U.P. Nair, N.P. Piesco, M.P. Mooney, H.-G. Grondahl

    Quantification of osseous healing is a challenging task, requiring expensive advanced imaging modalities. To improve diagnostic osseous imaging, we undertook this prospective study to explore the potential of Tuned Aperture Computed Tomography®. Eighty defects in 20 rabbit mandibles, randomly carrying an osteoblast suspension or a polymer matrix or a combination thereof or no treatment, were imaged at 3, 6, 9, and 12 weeks post-surgery. TACT slices, iteratively restored TACT, and conventional digital radiographs were evaluated. Mean-gray-value distribution within regions of interest was correlated with histomorphometric data. Lesions treated with osteoblast/polymer-matrix delivery systems demonstrated the highest mean gray-value, while the diagnostic efficacy of TACT-IR was significantly better than that of other imaging modalities (p < 0.001). Thus, TACT is an accurate imaging modality for non-destructive quantification of osseous dynamics.


    • 19 May 2001
      • Vol. 26  (3) , 223-30

    Diagnostic accuracy of intraoral film and direct digital images for detection of simulated recurrent decay.

    by M K Nair, J B Ludlow, K N May, U P Nair, M P Johnson, J M Close

    This study compared the diagnostic accuracy of bitewing images for detection of simulated recurrent caries using the following imaging modalities: Ektaspeed Plus film and different digital imaging system technologies comprised of a charge-coupled device (CCD) based digital imaging unit, a photo-stimulable phosphor (PSP) based unit and contrast- and brightness-enhanced PSP images. Twenty-four extracted posterior teeth with MOD inlay preparations were secured in models simulating a natural arrangement of teeth. Lesions were created in proximal boxes using dental burs of varying sizes. Defects were filled with wax and plaster and preparations were restored with composite or amalgam. Averages of receiver operating curve areas (Az) revealed diagnostic performances of Az = 0.74 for film, Az = 0.80 for CCD, Az = 0.73 for unenhanced PSP and Az = 0.64 for enhanced PSP. The differences between these means were significant (MANOVA p < 0.0001). Unenhanced PSP produced significantly poorer performance than other modalities. CCD performance was not significantly better than enhanced PSP. Lesions under radiopaque composite restorations were easier to detect, followed by those under amalgam and radiolucent composites across imaging modalities and lesion locations. Based on lesion location, those located at the buccal point angle were easiest to detect, followed by those at mid-gingival floor and lingual-point angle sites. Contrast and brightness-enhanced digital images enabled better signal detection and a comparable performance with film for detection of artificially induced recurrent caries.